基于无创三维对比增强超声压力估测对不确定性乳腺病变的表征
恶性与良性病变的SHAPE梯度分别为2.86±3.24 vs -0.03±1.72 a.u.(p=0.03),有创压力梯度分别为9.9±8.5 vs 20.9±8.0 mmHg(p=0.008)。SHAPE梯度与有创压力梯度检测恶性的AUC分别为0.79和0.88,特异度分别为77%和92%,敏感度分别为88%和50%,两者呈弱负相关(r=-0.2)。
要点
- 恶性病变SHAPE梯度为2.86±3.24 a.u.,良性为-0.03±1.72 a.u.,组间差异p=0.03。
- SHAPE梯度检测恶性的AUC为0.79、敏感度88%、特异度77%。
- 有创压力梯度检测恶性的AUC为0.88、敏感度50%、特异度92%。
核心结论
- 三维SHAPE估测的乳腺病变与邻近正常组织间压力梯度显示出表征不确定性乳腺病变的潜力。
诊断标准与关键数值
- SHAPE梯度检测恶性:AUC 0.79、敏感度88%、特异度77%;有创压力梯度检测恶性:AUC 0.88、敏感度50%、特异度92%。
局限性
- SHAPE梯度与有创压力梯度仅呈弱负相关(r=-0.2)。
- 作者结论仅称三维SHAPE显示出表征不确定性乳腺病变的潜力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the ability of the pressure gradient between breast lesions and adjacent normal tissue estimated by 3D subharmonic-aided pressure estimation (SHAPE) to characterize indeterminate breast lesions.
METHODS: This prospective study enrolled patients scheduled for ultrasound-guided needle biopsies of a breast lesion. Before the biopsy, 3D SHAPE data were collected from the breast lesion during the infusion of an ultrasound contrast agent (Definity) as well as after clearance of the agent. Direct, invasive pressure measurements in the lesion and adjacent normal tissue were then obtained using an intracompartmental pressure monitoring system (C2DX) before tissue sampling as part of the biopsy procedure. The mean SHAPE gradient and invasive measurement gradient between the lesion and adjacent normal tissue were compared to the biopsy results. The SHAPE gradients were also compared to the invasive pressure gradients.
RESULTS: There were 8 malignant and 13 benign lesions studied. The SHAPE gradients and invasive pressure gradients were significantly different between the benign and malignant lesions (2.86 ± 3.24 vs. -0.03 ± 1.72 a.u.; p = 0.03 and 9.9 ± 8.5 vs. 20.9 ± 8.0 mmHg; p = 0.008, respectively). The area under the curves, specificities, and sensitivities for detecting malignancy by SHAPE gradients and invasive pressure gradients were 0.79 and 0.88, 77% and 92%, and 88% and 50%, respectively. A weak negative correlation was found between the SHAPE and invasive pressure gradients (r = -0.2).
CONCLUSION: The pressure gradient between a breast lesion and adjacent normal tissue estimated by 3D SHAPE shows potential for characterizing indeterminate breast lesions.
引用
- Nam K, Torkzaban M, Shames JP, et al. Characterization of Indeterminate Breast Lesions Based on Pressure Estimates by Noninvasive 3D Contrast-Enhanced Ultrasound. Ultrasound Med Biol. 2024. PMID: 39237425. doi:10.1016/j.ultrasmedbio.2024.08.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。