文献速递妇产影像泌尿生殖MR

弥散加权成像评估宫颈癌女性淋巴结转移:表观弥散系数值的Meta分析

Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values.
PubMed 文献 · Acad Radiol · 2024-09-25

该Meta分析纳入16篇文献共1156例患者,评估DWI及ADC值鉴别宫颈癌患者良恶性淋巴结的诊断效能。所有研究合并的最佳ADC阈值为0.985×10⁻³ mm²/s,敏感度84%、特异度94%;含b值1000 s/mm²的研究最佳阈值为0.9435×10⁻³ mm²/s,敏感度100%、特异度93%。作者认为含b值1000 s/mm²的DWI能充分鉴别良恶性淋巴结。

要点

  • 所有研究合并的最佳ADC阈值为0.985×10⁻³ mm²/s,敏感度84%、特异度94%。
  • 含b值1000 s/mm²的研究最佳ADC阈值为0.9435×10⁻³ mm²/s,敏感度100%、特异度93%。
  • b值达800 s/mm²的研究最佳ADC阈值为0.985×10⁻³ mm²/s,敏感度62%、特异度100%。

核心结论

  • 含b值1000 s/mm²的DWI研究敏感度和特异度高于b值达800 s/mm²的研究。
  • 在0.9435×10⁻³ mm²/s阈值下,DWI能充分鉴别良性与转移性淋巴结。

研究设计与样本

  • 研究类型为Meta分析,检索MEDLINE和EMBASE数据库。
  • 共纳入16篇文章、1156例患者。
  • 采用QUADAS-2评估方法学质量。
  • 按三个亚组分析:所有研究、最大b值为800 s/mm²的研究、包含b值1000 s/mm²的研究。
  • 构建ROC曲线并计算AUC,采用最大约登指数确定最佳ADC阈值。

诊断标准与关键数值

  • 所有研究合并:最佳ADC阈值0.985×10⁻³ mm²/s,最大约登指数0.77,敏感度84%、特异度94%。
  • 最大b值为800 s/mm²的研究:最佳ADC阈值0.985×10⁻³ mm²/s,最大约登指数0.62,敏感度62%、特异度100%。
  • 包含b值1000 s/mm²的研究:最佳ADC阈值0.9435×10⁻³ mm²/s,最大约登指数0.93,敏感度100%、特异度93%。

局限性

  • 总体质量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic performance of Diffusion Weighted Imaging (DWI) and provide optimal apparent diffusion coefficient (ADC) cut-off values for differentiating between benign and metastatic lymph nodes in women with uterine cervical cancer.

METHOD: MEDLINE and EMBASE databases were searched. Methodological quality was assessed with QUADAS-2. Data analysis was performed for three subgroups: (1) All studies; (2) Studies with maximum b-values of 800 s/mm², and (3) Studies containing b-values of 1000 s/mm². Receiver-operating characteristics (ROC) curves were constructed and the area under the curve (AUC) was calculated. The maximum Youden index was used to determine optimal ADC cut-off values, following calculations of sensitivity and specificity.

RESULTS: 16 articles (1156 patients) were included. Overall, their quality was limited. For all studies combined, the optimum ADC cut-off value was 0.985×10⁻³ mm²/s at maximum Youden Index of 0.77, resulting in sensitivity and specificity of 84%, and 94%, respectively. Studies with b-values up to 800 s/mm², gave an optimum ADC cut-off value of 0.985×10⁻³ mm²/s at maximum Youden Index of 0.62, with a sensitivity and specificity of 62%, and 100%. Studies containing b-values of 1000 s/mm² gave an optimum ADC cut-off value of 0.9435×10⁻³ mm²/s at maximum Youden Index of 0.93, with a sensitivity and specificity of 100%, and 93%, respectively.

CONCLUSION: Studies using DWI including b-values of 1000 s/mm² have higher sensitivity and specificity than those with b-values up to 800 s/mm². At the cut-off value of 0.9435×10⁻³ mm²/s DWI can sufficiently discriminate between benign and metastatic lymph nodes.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Distelbrink RF, Celebi E, Mom CH, et al. Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values. Acad Radiol. 2024. PMID: 39327136. doi:10.1016/j.acra.2024.09.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。