文献速递泌尿生殖技术与安全MR

PI-QUAL第二版:一项在多参数MRI上的多读者可重复性研究,来自一家三级转诊中心

PI-QUAL version 2: A Multi-Reader reproducibility study on multiparametric MRI from a tertiary referral center.
PubMed 文献 · Eur J Radiol · 2024-09-05

在三级转诊中心对50例男性3T多参数MRI图像,由6名不同经验读者分两次使用PI-QUAL v.2及v.1评估。PI-QUAL v.2读者间一致性总体中等(Gwet AC1=0.55),专家读者高于初学者和基础读者;读者内一致性中等至完美,且随经验增加而提高;DWI和DCE序列比T2w更可重复;v.2与v.1读者内一致性几乎完美至完美(Gwet AC1=0.96-1.00)。结论认为PI-QUAL v.2是中等可靠的工具。

要点

  • PI-QUAL v.2读者间一致性总体中等(Gwet AC1=0.55),专家读者高于初学者和基础读者。
  • 读者内一致性中等至完美(Gwet AC1=0.43-1.00),随经验增加而提高。
  • DWI和DCE序列评分比T2w更可重复(Gwet AC1=0.62-1.00 vs 0.24-0.70)。

核心结论

  • 在三级转诊中心背景下,PI-QUAL v.2是中等可靠的工具,用于标准化不同经验读者间的前列腺mpMRI质量评估。

研究设计与样本

  • 研究纳入50例男性,在三级转诊中心行3T多参数MRI扫描;图像匿名后由6名不同经验读者(2名专家、2名基础、2名初学者)分两次评估,先使用PI-QUAL v.2,2周间隔后同时使用PI-QUAL v.2和v.1;采用Gwet AC1指数计算读者间和读者内一致性。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the inter-reader and intra-reader agreement of the Prostate imaging quality version 2 (PI-QUAL v.2) for multiparametric magnetic resonance imaging (mpMRI) among radiologists with varying levels of expertise.

METHODS: Fifty men underwent 3 T mpMRI scans in a tertiary referral center. Images were anonymized and assessed by six readers of different expertise (2 expert, 2 basic and 2 beginners) in two sessions: first using PI-QUAL v.2, and then using both PI-QUAL v.2 and v.1 after a 2-week interval. PI-QUAL v.2 scores were considered overall and, for comparison with PI-QUAL v.1, dichotomized according to the threshold of acceptable image quality. Gwet AC1 index was used to calculate the inter-reader and intra-reader agreement of the scores.

RESULTS: The inter-reader agreement for PI-QUAL v.2 scores was overall moderate (Gwet's AC1 = 0.55), being higher for expert readers compared to the beginner and basic ones (Gwet's AC1 = 0.66 versus 0.45-0-58). Intra-reader agreement varied from moderate to perfect (Gwet's AC1 = 0.43-1.00) and improved with increasing levels of expertise. The ratings were more reproducible for DWI and DCE sequences (Gwet's AC1 = 0.62-1.00) compared to T2w (Gwet's AC1 = 0.24-0.70). The intra-reader agreement between PI-QUAL v.2 and v.1 scores across readings ranged from almost perfect to perfect (Gwet's AC1 = 0.96-1.00).

CONCLUSIONS: In a tertiary referral center context, PI-QUAL v.2 is a moderately reliable tool for standardizing prostate mpMRI quality evaluations among readers with varying expertise.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ponsiglione A, Cereser L, Spina E, et al. PI-QUAL version 2: A Multi-Reader reproducibility study on multiparametric MRI from a tertiary referral center. Eur J Radiol. 2024. PMID: 39260208. doi:10.1016/j.ejrad.2024.111716

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。