文献速递腹部CT

采用智能检查协议实现亚毫希沃特CT结肠成像以准确检测结直肠肿瘤:一项前瞻性自身对照研究

Achieving sub-millisievert CT colonography for accurate colorectal tumor detection using smart examination protocols: a prospective self-controlled study.
PubMed 文献 · Abdom Radiol (NY) · 2024-09-14

前瞻性纳入90例疑似结直肠癌患者,俯卧位行标准剂量CTC(120 kVp、ASIR-V 30%、NI 13),仰卧位行超低剂量CTC(Auto-kVp选择80或100 kVp、ASIR-V 60%、80 kVp时NI 13、100 kVp时NI 15)。超低剂量组有效剂量显著低于标准剂量组,肿瘤SNR和CNR更高,主观图像质量无差异且观察者间一致性良好,两组肿瘤检出率高且定位与手术结果一致性良好。

要点

  • 超低剂量CTC采用Auto-kVp选择、ASIR-V 60%及相应NI,80 kVp亚组平均有效剂量0.70 mSv,100 kVp亚组0.98 mSv。
  • 超低剂量CTC肿瘤SNR和CNR高于标准剂量CTC(P < 0.05),主观图像质量无差异,Kappa 0.805-0.923。
  • 两组CTC定位与手术报告一致性良好,Kappa 0.718-0.989,支持亚毫希沃特CTC用于结直肠肿瘤检测和定位。

核心结论

  • 联合Auto-kVp选择、较高预设ASIR-V和NI可实现个体化亚毫希沃特CTC,在检测和定位结直肠癌方面表现良好,与手术结果一致,且标准剂量与超低剂量CTC结果一致。

研究设计与样本

  • 前瞻性自身对照研究,纳入90例疑似结直肠癌患者,俯卧位行标准剂量CTC(120 kVp、预设ASIR-V 30%、SmartmA、NI 13),仰卧位行超低剂量CTC(Auto-kVp选择80或100 kVp、预设ASIR-V 60%、80 kVp时SmartmA NI 13、100 kVp时NI 15),以手术结果为参考标准评估肿瘤定位准确性。

诊断标准与关键数值

  • 超低剂量CTC-80 kVp亚组平均有效剂量0.70 mSv,较120 kVp组2.45 mSv降低71.43%;超低剂量CTC-100 kVp亚组0.98 mSv,较120 kVp组3.63 mSv降低73.00%(P < 0.001)。
  • 超低剂量CTC肿瘤SNR和CNR高于标准剂量CTC(P < 0.05),主观图像质量两组无差异,观察者间一致性Kappa 0.805-0.923。
  • 标准剂量与超低剂量CTC肿瘤定位与手术报告一致性Kappa 0.718-0.989。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the feasibility of combining Auto-kVp selection technique, higher preset ASIR-V and noise index (NI) to realize individualized sub-mSv CT colonography (CTC) for accurate colorectal tumor detection and localization.

METHODS: Ninety patients with suspected colorectal cancer (CRC) were prospectively enrolled to undergo standard dose CTC (SDCTC) in the prone and ultra-low dose CTC (ULDCTC) in the supine position. SDCTC used 120 kVp, preset ASIR-V of 30%, SmartmA for a NI of 13; ULDCTC used Auto-kVp selection technique with 80 or 100 kVp, preset ASIR-V of 60%, SmartmA for a NI of 13 for 80 kVp, and NI of 15 for 100 kVp. The effective dose (ED), image quality [signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of colorectal neoplasms] between the two protocols were compared and the accuracies of tumor locations were evaluated for CTC in comparison with the surgery results.

RESULTS: The mean ED of the ULDCTC-80 kVp subgroup was 0.70 mSv, 71.43% lower than the 2.45 mSv for the 120 kVp group, while that of the ULDCTC-100 kVp subgroup was 0.98 mSv, 73.00% lower than the 3.63 mSv for the 120 kVp group (P < 0.001). The tumor SNR and CNR of the ULDCTC were higher than those of SDCTC (P < 0.05), while there was no difference in the subjective image quality between them with good inter-observer agreement (Kappa: 0.805-0.923). Both SDCTC and ULDCTC groups had high detection rate of colorectal tumors, along with good consistency in determining tumor location compared with surgery reports (Kappa: 0.718-0.989).

CONCLUSION: The combination of Auto-kVp selection, higher preset ASIR-V and NI achieves individualized sub-mSv CTC with good performance in detecting and locating CRC with surgery and consistent results between SDCTC and ULDCTC.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang J, Hu M, Cheng Q, et al. Achieving sub-millisievert CT colonography for accurate colorectal tumor detection using smart examination protocols: a prospective self-controlled study. Abdom Radiol (NY). 2024. PMID: 39276190. doi:10.1007/s00261-024-04557-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。