文献速递腹部技术与安全USMR

比较三种超声技术对代谢功能障碍相关脂肪性肝病肝脏脂肪变性的诊断与分级

Comparing Three Ultrasound-Based Techniques for Diagnosing and Grading Hepatic Steatosis in Metabolic Dysfunction-Associated Steatotic Liver Disease.
PubMed 文献 · Acad Radiol · 2024-09-17

本研究以磁共振成像质子密度脂肪分数(PDFF)为金标准,比较超声衍生脂肪分数(UDFF)、受控衰减参数(CAP)和肝/肾比值(HRR)对代谢功能障碍相关脂肪性肝病(MASLD)肝脏脂肪变性的诊断准确性和分级能力。结果显示UDFF与PDFF相关性最强(ρ=0.91),对各分级诊断效能均优于CAP和HRR(p<0.05),而CAP与HRR各分级AUC差异无统计学意义。

要点

  • UDFF与PDFF相关性最强(ρ=0.91),诊断各分级脂肪变性的AUC均高于CAP和HRR(p<0.05)。
  • UDFF诊断≥S1、≥S2、≥S3的AUC分别为0.99、0.96、0.97,最佳阈值分别为6%、15%、23%。
  • CAP与HRR在各分级间的AUC差异均无统计学意义。

核心结论

  • UDFF对MASLD肝脏脂肪变性的检测和分级诊断准确性优于CAP和HRR。
  • 多因素分析显示年龄、UDFF和CAP是MASLD肝脏脂肪变性的重要影响因素。

研究设计与样本

  • 本研究为单中心研究,纳入2023年10月至2024年5月本院疑似MASLD患者,分为MASLD组(115例)和对照组(102例)。
  • 所有患者接受UDFF、CAP和PDFF检查,HRR在常规超声检查中测量。
  • 以MRI质子密度脂肪分数(PDFF)为金标准,采用ROC曲线评估并比较UDFF、CAP和HRR对不同分级肝脏脂肪变性的诊断效能,并通过二元logistic回归分析确定预测因素。

诊断标准与关键数值

  • UDFF诊断≥S1的AUC为0.99(95%CI 0.97-1.00),最佳阈值为≥6%。
  • UDFF诊断≥S2的AUC为0.96(95%CI 0.93-0.98),最佳阈值为≥15%。
  • UDFF诊断≥S3的AUC为0.97(95%CI 0.94-0.99),最佳阈值为≥23%。
  • UDFF、CAP和HRR均与PDFF呈正相关,其中UDFF相关性最强(ρ=0.91)。
  • UDFF在不同分级肝脏脂肪变性中的诊断效能均优于CAP和HRR(p<0.05),而CAP与HRR在所有三个分级中的AUC差异均无统计学意义。

临床应用与阅片要点

  • 在MASLD肝脏脂肪变性的诊断和分级中,UDFF可能提供优于CAP和HRR的诊断准确性。
  • UDFF的推荐阈值(≥6%为S1,≥15%为S2,≥23%为S3)可用于日常超声检查中的分级参考。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To compare the diagnostic accuracy and grading ability of ultrasound-derived fat fraction (UDFF), controlled attenuation parameters (CAP), and hepatic/renal ratio (HRR) for hepatic steatosis in metabolic dysfunction-associated steatotic liver disease (MASLD) using magnetic resonance imaging proton density fat fraction (PDFF) as the gold standard.

METHODS: Patients suspected of having MASLD in our hospital between October 2023 and May 2024 were divided into the MASLD group and the control group. All patients underwent UDFF, CAP, and PDFF examinations. HRR was measured during routine ultrasound examination. In statistical analysis, we initially assessed the correlation between UDFF, CAP, HRR, and general characteristics of subjects with PDFF. Subsequently, receiver operating characteristic curve were employed to evaluate and compare the diagnostic performance of UDFF, CAP, and HRR for different grades of hepatic steatosis in MASLD. Their area under the curve, optimal cut-off value, sensitivity, and specificity were also determined. Finally, predictive factors determined hepatic steatosis in MASLD (PDFF≥6%) were identified through binary logistic regression analysis.

RESULTS: 115 individuals were ultimately included in the MASLD group, while 102 were included in the control group. UDFF, CAP, and HRR were all positively correlated with PDFF. Among them, UDFF exhibited the strongest correlation with PDFF (ρ = 0.91). Furthermore, in the comparison of diagnostic efficacy among different grades of hepatic steatosis, UDFF outperformed CAP and HRR (p < 0.05). However, there were no statistically significant differences in AUCs between CAP and HRR across all three grades. The AUCs for UDFF in ≥S1, ≥S2, and ≥S3 were 0.99 (95% CI 0.97 to 1.00), 0.96 (95% CI 0.93 to 0.98), and 0.97 (95% CI 0.94 to 0.99), respectively. The optimal thresholds for UDFF are determined as follows: ≥ 6% for grade S1; ≥ 15% for grade S2; and ≥ 23% for grade S3. Multivariate analysis revealed that only age, UDFF, and CAP were important influencing factors for hepatic steatosis in MASLD.

CONCLUSION: The diagnostic accuracy of UDFF surpassed that of CAP and HRR in the detection and grading of hepatic steatosis in MASLD.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang P, Song D, Han J, et al. Comparing Three Ultrasound-Based Techniques for Diagnosing and Grading Hepatic Steatosis in Metabolic Dysfunction-Associated Steatotic Liver Disease. Acad Radiol. 2024. PMID: 39294051. doi:10.1016/j.acra.2024.09.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。