光子计数探测器CT用于肝脏脂肪定量:在代谢功能障碍相关脂肪性肝病中跨协议验证

Photon-counting Detector CT for Liver Fat Quantification: Validation across Protocols in Metabolic Dysfunction-associated Steatotic Liver Disease.
PubMed 文献 · Radiology · 2024-01-01

这项前瞻性研究在体模、412名无症状参与者和122名疑似MASLD参与者中,开发并验证了光子计数探测器CT的CT值到MRI质子密度脂肪分数的通用转换公式:MRI PDFF (%) = -0.58 · CT (HU) + 43.1。CT推导脂肪分数与PDFF在各管电压、辐射剂量和BMI亚组中平均偏差均<1%,提示标准化CT值可能作为肝脏脂肪定量的精确替代方法。

要点

  • PCD CT标准化CT值经公式MRI PDFF(%) = -0.58·CT(HU)+43.1转换后,与MRI PDFF平均偏差<1%。
  • CTFF误差不受管电压(90/120/140 kVp)、辐射剂量(标准/低)、BMI或PDFF影响。
  • 在MASLD队列中CTFF与PDFF同样一致,平均偏差-0.2%。

核心结论

  • 光子计数探测器CT的标准化CT值与MRI PDFF在各种协议下均表现出稳健且高度一致,可能作为肝脏脂肪定量的精确替代方法。

研究设计与样本

  • 前瞻性研究,纳入500名无症状参与者和157名疑似MASLD参与者(2023年9月至2024年3月),随机分配至6种CT协议组(管电压90/120/140 kVp与标准或低辐射剂量组合);120 kVp标准剂量无症状组中51%(53/104)为训练队列,其余无症状组为验证队列;最终纳入412名无症状参与者和122名MASLD参与者;以MRI PDFF为参考标准。

诊断标准与关键数值

  • 推导的CT到MRI脂肪转换公式为MRI PDFF (%) = -0.58 · CT (HU) + 43.1;体模中CTFF与名义脂肪分数组内相关系数0.98、平均偏差0.2%;所有比较中CTFF与PDFF平均偏差<1%;MASLD队列中平均偏差-0.2%。

临床应用与阅片要点

  • 可利用光子计数探测器CT标准化CT值按公式MRI PDFF(%) = -0.58·CT(HU)+43.1估算肝脏脂肪分数,其与MRI PDFF一致性不受管电压、辐射剂量、BMI或PDFF影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Traditional energy-integrating detector CT has limited utility in accurately quantifying liver fat due to protocol-induced CT value shifts, but this limitation can be addressed by using photon-counting detector (PCD) CT, which allows for a standardized CT value. Purpose To develop and validate a universal CT to MRI fat conversion formula to enhance fat quantification accuracy across various PCD CT protocols relative to MRI proton density fat fraction (PDFF). Materials and Methods In this prospective study, the feasibility of fat quantification was evaluated in phantoms with various nominal fat fractions. Five hundred asymptomatic participants and 157 participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) were enrolled between September 2023 and March 2024. Participants were randomly assigned to six groups with different CT protocols regarding tube voltage (90, 120, or 140 kVp) and radiation dose (standard or low). Of the participants in the 120-kVp standard-dose asymptomatic group, 51% (53 of 104) were designated as the training cohort, with the rest of the asymptomatic group serving as the validation cohort. A CT to MRI fat quantification formula was derived from the training cohort to estimate the CT-derived fat fraction (CTFF). CTFF agreement with PDFF and its error were evaluated in the asymptomatic validation cohort and subcohorts stratified by tube voltage, radiation dose, and body mass index, and in the MASLD cohort. The factors influencing CTFF error were further evaluated. Results In the phantoms, CTFF showed excellent agreement with nominal fat fraction (intraclass correlation coefficient, 0.98; mean bias, 0.2%). A total of 412 asymptomatic participants and 122 participants with MASLD were included. A CT to MRI fat conversion formula was derived as follows: MRI PDFF (%) = -0.58 · CT (HU) + 43.1. Across all comparisons, CTFF demonstrated excellent agreement with PDFF (mean bias values < 1%). CTFF error was not influenced by tube voltage, radiation dose, body mass index, or PDFF. Agreement between CTFF and PDFF was also found in the MASLD cohort (mean bias, -0.2%). Conclusion Standardized CT value from PCD CT showed a robust and remarkable agreement with MRI PDFF across various protocols and may serve as a precise alternative for liver fat quantification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Wildman-Tobriner in this issue.