脑电双频指数传感器引导提高程序性镇静的准确性和安全性
在修订镇静方案后,以14项标准对150例连续接受透视及联合内镜操作的患者进行再审核,由介入放射科护士依据脑电双频指数(BIS)测量将联合镇静镇痛滴定至BIS 80–85。84%患者达轻度或中度镇静(BIS 70–89),无患者需镇静逆转或气道管理,无低氧血症发生。
要点
- BIS引导下将联合镇静镇痛滴定至BIS 80–85,84%患者达轻度或中度镇静(BIS 70–89)。
- 150例连续患者中无患者需镇静逆转或气道管理,无患者发生低氧血症。
- BIS引导可实时评估患者对镇静镇痛的反应并预测进一步给药的安全性。
核心结论
- BIS引导镇静给药可实时评估患者对联合镇静镇痛的反应并预测进一步给药的安全性,能识别患者苏醒、减少操作中断,较间隔评估临床反应具有明确临床优势,并减少镇静不足与过度镇静。
研究设计与样本
- 审计研究:修订科室镇静方案后设定14项标准,对150例连续接受透视及联合内镜操作的患者评估镇静数据与结局;由介入放射科护士依据BIS测量将联合镇静镇痛滴定至BIS 80–85,剂量按患者年龄和ASA状态分层,给予鼻氧并用脉搏血氧饱和度及二氧化碳波形图等标准监测评估并发症(尤其≤94%的低氧血症)。
诊断标准与关键数值
- 联合镇静镇痛由介入放射科护士依据BIS测量滴定,目标BIS读数80–85。
- 84%患者被归类为接受轻度或中度镇静(BIS 70–89)。
- 14项标准中有3项患者镇静标准未达标。
临床应用与阅片要点
- BIS引导可实时评估患者对联合镇静镇痛的反应,并预测进一步给药的安全性。
- BIS引导可识别患者苏醒,使苏醒可被预先估计并减少操作中断。
- BIS引导较间隔评估患者对临床刺激的反应具有明确临床优势,并减少镇静不足与过度镇静。
局限性
- 14项标准中有3项患者镇静标准未达标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To re-audit compliance with an amended sedation protocol following the latest national guidelines. To confirm the improved safety achieved through EEG guidance for drug administration during procedural sedation.
MATERIALS AND METHODS: Following the revision of the departmental protocol, 14 standards were set. Sedation data and outcomes in 150 consecutive patients undergoing fluoroscopic and combined endoscopic procedures were evaluated against these. Combination sedo-analgesia was titrated by the interventional radiology nurses guided by bispectral index sensor (BIS) measurements to achieve readings between 80 and 85. Doses were stratified by patient age and ASA status. Nasal oxygen was given and standard monitoring including pulse oximetry and capnography were used alongside to assess for complications, notably hypoxaemia of ≤ 94%.
RESULTS: 85% were non-vascular procedures, the bulk made up of oesophageal stent insertion, gastrostomy, oesophageal dilatation of radiation strictures and biliary procedures. Mean procedure time was 32.9 minutes (10-170). Mean doses of midazolam and fentanyl were 3.99mg (±1.9) and 92.3μg (±35.4), respectively. 84% of patients were classified as having received light or moderate sedation (BIS 70-89). Three standards for patient sedation were missed, but no patient required sedation reversal or airway management, and none developed hypoxaemia.
CONCLUSIONS: BIS guidance of sedation administration allows real-time assessment of the patient's response to sedo-analgesia administered and allows prediction about the safety of further drug administration. It identifies patients waking up, allowing this to be anticipated and reduces interruptions of the procedure. It offers clear clinical advantages to interval assessment of patients' response to clinical stimuli and reduces under-as well as oversedation.
引用
- Oh A, Karim N, Pitt A, et al. EEG bispectral index sensor guidance improves accuracy and safety of procedural sedation. Clin Radiol. 2024. PMID: 39317529. doi:10.1016/j.crad.2024.08.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。