3特斯拉下深度学习加速单次激发涡轮自旋回波序列联合增强去噪用于胰腺MRI的临床可行性
纳入2021年3月至4月行胰腺MRI的63例患者,比较传统HASTE与联合增强去噪的HASTEDL图像质量及定量参数。增强去噪HASTEDL除读者2的伪影外图像质量参数均显著更优,总体图像质量评分显著高于传统HASTE,胰腺囊性病变及实质SNR显著更高,采集时间由69秒缩短至18秒。
要点
- 增强去噪HASTEDL总体图像质量评分显著高于传统HASTE(3.26±0.54 vs. 2.47±0.56,p<0.001)。
- 增强去噪HASTEDL的胰腺囊性病变及胰腺实质SNR均显著更高(两者p<0.001)。
- 采集时间传统HASTE为69秒,HASTEDL为18秒。
核心结论
- 增强去噪HASTEDL可能有助于缩短胰腺MRI采集时间,同时改善评估胰腺囊性病变的图像质量。
研究设计与样本
- 纳入2021年3月至4月行胰腺MRI的患者63例,其中48例(76.2%)共有136个胰腺囊性病变;采集4组T2加权图像:非脂肪抑制传统HASTE、非脂肪抑制增强去噪HASTEDL、脂肪抑制增强去噪HASTEDL、脂肪抑制HASTEDL;两名读者独立采用4点Likert量表评估两组非脂肪抑制图像的图像质量参数。
关键影像表现/征象
- 除读者2的伪影外,增强去噪HASTEDL的所有图像质量参数均显著优于传统HASTE。
- 增强去噪HASTEDL的总体图像质量评分显著高于传统HASTE(3.26±0.54 vs. 2.47±0.56,p<0.001)。
- 增强去噪HASTEDL的胰腺囊性病变及胰腺实质SNR均显著更高(两者p<0.001)。
- 测量胰腺囊肿大小的读者间一致性在增强去噪HASTEDL中低于传统HASTE(ICC 0.999 vs. 0.995;95%LoA -0.13481至0.14743 vs. -0.24097至0.27404)。
- 测量胰管直径的读者间一致性在增强去噪HASTEDL中低于传统HASTE(ICC 0.994 vs. 0.969;95%LoA -0.11684至0.36026 vs. -0.45544至0.44664)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the feasibility of the single-shot turbo spin echo sequence using deep learning-based reconstruction (DLR) (HASTEDL) with enhanced denoising for pancreas MRI.
METHODS: Patients who underwent pancreas MRI from March to April 2021 were included. Four T2-weighted images (non-FS conventional HASTE vs. HASTEDL with enhanced denoising and FS HASTEDL with enhanced denoising vs. HASTEDL) were acquired. Two readers independently assessed the image quality parameters of the two non-FS image sets using a 4-point Likert scale. The signal-to-noise ratio (SNR) of the cystic lesions and pancreatic parenchyma and the contrast-to-noise ratio between the cystic lesion and pancreatic parenchyma were calculated for all four image sets. The size of the largest cystic lesion and the diameter of pancreatic duct were measured.
RESULTS: A total of 63 patients were included, 48 (76.2 %) of whom had 136 pancreatic cystic lesion(s). The acquisition times of conventional HASTE and HASTEDL were 69 and 18 sec, respectively. All image quality parameters except artifacts for reader 2 were significantly better for HASTEDL with enhanced denoising. Those images also received scores for overall image quality that were significantly higher than those for the conventional HASTE (3.26 ± 0.54 vs. 2.47 ± 0.56, p < 0.001). The SNR of the pancreatic cystic lesion and pancreatic parenchyma was significantly higher in the HASTEDL with enhanced denoising (p < 0.001 for both). Inter-reader variability for measuring the pancreatic cyst size (ICC, 0.999 vs. 0.995; 95 % LoA, -0.13481 to 0.14743 vs. -0.24097 to 0.27404) and duct diameter (ICC, 0.994 vs. 0.969; 95 % LoA, -0.11684 to 0.36026 vs. -0.45544 to 0.44664) was lower in HASTEDL with enhanced denoising than in the conventional HASTE.
CONCLUSION: HASTEDL with enhanced denoising could be useful for reducing the acquisition time of pancreas MRI while improving the image quality for the evaluation of pancreatic cystic lesions.
引用
- Kim JW, Park BN, Nickel D, et al. Clinical feasibility of deep learning-accelerated single-shot turbo spin echo sequence with enhanced denoising for pancreas MRI at 3 Tesla. Eur J Radiol. 2024. PMID: 39305750. doi:10.1016/j.ejrad.2024.111737
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。