超声成像中不同视野角度测量肝脏大小的变异性

Variability in Liver Size Measurements Using Different View Angles in Ultrasound Imaging.
PubMed 文献 · J Ultrasound Med · 2024-09-09

本研究以MRI测量为参考,比较三种常规B型超声视野(90°、120°、140°)下测量成人肝脏最大矢状径和横径的差异。28例参与者按矢状径分为<17 cm组(10例)和≥17 cm组(18例),三视野间测量值差异有统计学意义(P<.001),超宽视野与MRI相关性最高(矢状R²=.87,横径R²=.79),Bland-Altman分析显示一致性良好,观察者内和观察者间信度良好(ICC=0.82-0.98)。研究提示超声超宽视野提供最准确的肝脏大小测量。

要点

  • 超宽视野(140°)测量肝脏大小与MRI相关性最高(矢状R²=.87,横径R²=.79)。
  • 不同视野角度(90°、120°、140°)间肝脏测量值差异有统计学意义(P<.001)。
  • 观察者内和观察者间测量肝脏大小的信度良好(ICC=0.82-0.98)。

核心结论

  • 超声超宽视野提供最准确的肝脏大小测量,且观察者内和观察者间信度良好。

研究设计与样本

  • 经机构审查委员会批准并获知情同意后,由三名操作者用单一凸阵探头在三种超声视野(90°、120°、140°)下测量成人肝脏最大矢状径和横径,以MRI测量为参考;共28例成人参与者(7男21女,平均年龄43岁),按矢状径分为<17 cm组(n=10)和≥17 cm组(n=18);采用单因素方差分析比较三视野间差异,Spearman回归分析MRI与超声测量的相关性,95% Bland-Altman一致性界限分析测量置信区间,组内相关系数评估信度。

诊断标准与关键数值

  • 以MRI测量为参考标准;超声超宽视野与MRI相关性最高(矢状R²=.87,横径R²=.79);Bland-Altman一致性界限显示MRI与超宽视野测量间一致性良好;观察者内和观察者间信度ICC=0.82-0.98;三视野间肝脏测量值差异有统计学意义(P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to compare liver size measurements in different conventional B-mode ultrasound image (US) field views using magnetic resonance imaging (MRI) measurement as a reference.

METHODS: After receiving Institutional Review Board approval and informed consent, three operators measured the largest sagittal and transverse dimensions of adult livers on three US image field views (90°, 120°, and 140°) with a single curvilinear transducer. We analyzed the differences in liver size across three image field views using one-way analysis of variance (ANOVA) and examined the correlations between MRI and ultrasound measurements using Spearman regression. We used 95% Bland-Altman limits of agreement (95% LOA) to analyze the confidence interval for liver size measurements between MRI and US. Intra-observer and inter-observer reliability in measuring liver size were assessed using intraclass correlation coefficient (ICC).

RESULTS: Based on sagittal liver length, 28 adult participants (7 men and 21 women, mean age 43 years) were divided into Group 1 (<17 cm, n = 10) or Group 2 (≥17 cm, n = 18). There was a significant difference in the liver size measurements across the three image field views (P < .001) in both groups. The highest correlation in liver size measurements between MRI and US was with ultra-wide-view (R2 = .87 in sagittal; R2 = .79 in transverse). Bland-Altman LOA also indicated good agreement between MRI and ultra-wide-view measurements. Intra-observer and inter-observer reliability in measuring liver size were good (ICC = 0.82-0.98).

CONCLUSION: The study suggests that ultrasound ultra-wide-view provides the most accurate liver size measurement and good intra- and inter-operator reliability.