文献速递腹部泌尿生殖CTMR

胃血管球瘤的影像学表现

Imaging findings of gastric glomus tumors.
PubMed 文献 · Abdom Radiol (NY) · 2024-09-14

本研究回顾性分析14例胃血管球瘤(良性10例、恶性4例)的CT或MR图像,发现良性肿瘤较恶性者更小(中位2.0 cm vs. 5.3 cm,p=0.03),更常呈均匀明显强化(9/10 vs. 0/4,p<0.01),且呈壁内生长而非外生性。T2信号和弥散受限在良恶性间无实质差异。作者认为,活检证实的胃血管球瘤大于5 cm或出现坏死可能为恶性。

要点

  • 良性胃血管球瘤中位大小2.0 cm,恶性5.3 cm,差异有统计学意义(p=0.03)。
  • 均匀明显强化见于良性9/10例、恶性0/4例(p<0.01)。
  • 良性者呈壁内生长,恶性者非壁内生长;T2信号和弥散受限无实质差异。

核心结论

  • 良性胃血管球瘤较恶性者更小、更常呈均匀明显强化且呈壁内生长;活检证实的胃血管球瘤大于5 cm或出现坏死可能为恶性。

研究设计与样本

  • 机构放射学和病理学数据库查询2010年1月至2023年12月诊断为胃血管球瘤的病例,最终纳入14例患者(男性6例),中位年龄65岁(范围31至79岁),由两名腹部放射科医生共识审阅所有相关CT和MR图像。

关键影像表现/征象

  • 良性胃血管球瘤中位大小2.0 cm,恶性5.3 cm(p=0.03)。
  • 良性者均匀明显强化9/10例,恶性者0/4例(p<0.01)。
  • 良性者呈壁内生长而非外生性生长。
  • 良性与恶性胃血管球瘤在T2信号或弥散受限方面无实质差异。
  • 随访中良性胃血管球瘤大小基本稳定,而恶性者增大。

诊断标准与关键数值

  • 活检证实的胃血管球瘤大于5 cm或显示坏死可能为恶性。

临床应用与阅片要点

  • 术前内镜超声引导细针穿刺抽吸可能无法确定恶性,影像上大于5 cm或坏死提示恶性可能。

局限性

  • 作者称既往文献对胃血管球瘤影像表现的描述稀少且集中于良性肿瘤,作者不知晓先前有恶性胃血管球瘤的放射学报道。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Sparse literature describes the imaging findings of gastric glomus tumors (GGT), focusing on benign tumors. We are not aware of prior radiology reports on malignant GGT. The aim of the study was to determine whether it is possible to differentiate between benign and malignant GGT on CT or MR. Institutional radiology and pathology databases were queried for the diagnosis of GGT between January 2010 to December 2023. Of 22 identified subjects, five were excluded due to non-availability of preoperative CT or MR images and three due to lack of pathological confirmation in our institution. The study cohort comprised of 14 patients (males = 6) with median age of 65 years (range 31 to 79 years). Two abdominal radiologists in consensus reviewed all relevant CT and MR images. There were 10 benign and 4 malignant GGT. Benign tumors were smaller than malignant GGT (median size of 2.0 cm vs. 5.3 cm, p = 0.03), more likely to exhibit homogeneous hyperenhancement (9/10 vs. 0/4, p < 0.01), and demonstrated intramural rather than exophytic growth. There was no substantial difference in T2 signal or diffusion restriction between benign and malignant GGT. On follow up, benign GGT were essentially stable in size, while malignant GGT grew. A biopsy proven GGT larger than 5 cm or showing necrosis is likely to be malignant. This is important since preoperative endoscopic ultrasound-guided fine needle aspiration may be indeterminate for malignancy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Sandrasegaran K, Shah A, Thompson C, et al. Imaging findings of gastric glomus tumors. Abdom Radiol (NY). 2024. PMID: 39276189. doi:10.1007/s00261-024-04549-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。