文献速递心血管MR

负荷心脏磁共振心肌血流量定量分析改善冠状动脉疾病检测

Myocardial Blood Flow Quantification Using Stress Cardiac Magnetic Resonance Improves Detection of Coronary Artery Disease.
PubMed 文献 · JACC Cardiovasc Imaging · 2024-09-18

这项多中心研究纳入127例接受负荷心脏磁共振检查者,比较定量负荷心肌血流量(sMBF)与心肌灌注储备(MPR)分析同有经验医师定性评估对阻塞性冠状动脉疾病(obCAD)的识别效能,结果显示整体sMBF与MPR的AUC分别为0.90和0.86,显著优于定性评估的平均AUC。

要点

  • 整体sMBF与MPR识别obCAD的AUC分别为0.90和0.86,4位医师定性评估AUC为0.69至0.88。
  • obCAD患者整体sMBF中位数1.5 mL/g/min,低于无obCAD者的2.4 mL/g/min(P < 0.001)。
  • obCAD患者整体MPR中位数1.3,低于无obCAD者的2.1(P < 0.001)。

核心结论

  • 双序列负荷心脏磁共振的sMBF与MPR能比有经验心脏磁共振阅片者的定性分析更准确地识别obCAD。

研究设计与样本

  • 多中心研究,纳入127例接受负荷心脏磁共振检查者(平均年龄62 ± 16岁,男性84例[67%]),以冠状动脉狭窄≥50%(左主干)或≥70%(主要血管)定义obCAD,由4位心脏磁共振专家进行定性评估。

关键影像表现/征象

  • 整体sMBF在obCAD者中位数为1.5 mL/g/min(Q1-Q3:1.2-1.8 mL/g/min),低于无obCAD者的2.4 mL/g/min(Q1-Q3:2.1-2.7 mL/g/min)(P < 0.001)。
  • 整体MPR在obCAD者中位数为1.3(Q1-Q3:1.0-1.6),低于无obCAD者的2.1(Q1-Q3:1.6-2.7)(P < 0.001)。
  • 在冠状动脉血管水平,obCAD血管的sMBF与MPR也显著低于无obCAD血管。

诊断标准与关键数值

  • obCAD定义为左主干冠状动脉狭窄≥50%或主要血管狭窄≥70%。
  • 整体sMBF识别obCAD的AUC为0.90(95% CI:0.84-0.96)。
  • 整体MPR识别obCAD的AUC为0.86(95% CI:0.80-0.93)。
  • 4位医师定性评估的AUC范围为0.69至0.88。
  • 整体sMBF与MPR的AUC显著优于定性评估的平均AUC。

临床应用与阅片要点

  • 采用双序列负荷心脏磁共振计算整体sMBF与MPR,可辅助识别obCAD。
  • 定量sMBF与MPR分析在识别obCAD方面可能比有经验医师的定性评估更准确。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) using stress cardiovascular magnetic resonance (CMR) have been shown to identify epicardial coronary artery disease. However, comparative analysis between quantitative perfusion and conventional qualitative assessment (QA) remains limited.

OBJECTIVES: The aim of this multicenter study was to test the hypothesis that quantitative stress MBF (sMBF) and MPR analysis can identify obstructive coronary artery disease (obCAD) with comparable performance as QA of stress CMR performed by experienced physicians in interpretation.

METHODS: The analysis included 127 individuals (mean age 62 ± 16 years, 84 men [67%]) who underwent stress CMR. obCAD was defined as the presence of stenosis ≥50% in the left main coronary artery or ≥70% in a major vessel. Each patient, coronary territory, and myocardial segment was categorized as having either obCAD or no obCAD (noCAD). Global, per coronary territory, and segmental MBF and MPR values were calculated. QA was performed by 4 CMR experts.

RESULTS: At the patient level, global sMBF and MPR were significantly lower in subjects with obCAD than in those with noCAD, with median values of sMBF of 1.5 mL/g/min (Q1-Q3: 1.2-1.8 mL/g/min) vs 2.4 mL/g/min (Q1-Q3: 2.1-2.7 mL/g/min) (P < 0.001) and median values of MPR of 1.3 (Q1-Q3: 1.0-1.6) vs 2.1 (Q1-Q3: 1.6-2.7) (P < 0.001). At the coronary artery level, sMBF and MPR were also significantly lower in vessels with obCAD compared with those with noCAD. Global sMBF and MPR had areas under the curve (AUCs) of 0.90 (95% CI: 0.84-0.96) and 0.86 (95% CI: 0.80-0.93). The AUCs for QA by 4 physicians ranged between 0.69 and 0.88. The AUC for global sMBF and MPR was significantly better than the average AUC for QA.

CONCLUSIONS: This study demonstrates that sMBF and MPR using dual-sequence stress CMR can identify obCAD more accurately than qualitative analysis by experienced CMR readers.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Wang S, Kim P, Wang H, et al. Myocardial Blood Flow Quantification Using Stress Cardiac Magnetic Resonance Improves Detection of Coronary Artery Disease. JACC Cardiovasc Imaging. 2024. PMID: 39297850. doi:10.1016/j.jcmg.2024.07.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。