冠状动脉微血管功能障碍中的血管重塑
前瞻性纳入153例心绞痛伴非阻塞性冠状动脉疾病(ANOCA)患者,用连续热稀释法测微血管阻力,冠脉CTA量化管腔容积和心肌质量。冠脉血流储备<2.5定义为CMD,微血管阻力>470 WU为高阻力。CMD伴高阻力者心外膜管腔容积较对照组小40%,CTA管腔容积检测高阻力的AUC为0.79。
要点
- ANOCA患者中CMD伴高微血管阻力者冠脉CTA管腔容积较无CMD者小40%。
- 冠脉CTA管腔容积与微血管阻力独立相关,检测高阻力AUC为0.79。
- 冠脉CTA管腔容积可能辅助ANOCA的诊断路径。
核心结论
- CMD伴高微血管阻力的患者心外膜血管较无CMD者小,冠脉CTA检测高微血管阻力具有很好的诊断能力,可能辅助ANOCA诊断路径。
研究设计与样本
- 前瞻性纳入153例ANOCA患者,行连续热稀释评估和冠脉CTA量化管腔容积及血管特异性心肌质量。
诊断标准与关键数值
- CMD定义为冠脉血流储备<2.5,高微血管阻力定义为>470 WU;CMD组冠脉血流储备1.9±0.38 vs 对照组3.2±0.81(P<0.001);CMD伴高阻力组管腔容积512.8±130.3 mm3 vs 对照组853.2±341.2 mm3(P<0.001),小40%;管腔容积与微血管阻力相关r=-0.59(95%CI:-0.45至-0.71;P<0.001);CTA管腔容积检测高阻力AUC 0.79(95%CI:0.69-0.88)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Approximately one-half of the patients with angina and nonobstructive coronary artery disease (ANOCA) have evidence of coronary microvascular dysfunction (CMD).
OBJECTIVES: This study aims to characterize patients with ANOCA by measuring their minimal microvascular resistance and to examine the pattern of vascular remodeling associated with these measurements.
METHODS: The authors prospectively included patients with ANOCA undergoing continuous thermodilution assessment. Lumen volume and vessel-specific myocardial mass were quantified using coronary computed tomography angiography (CTA). CMD was defined as coronary flow reserve <2.5 and high minimal microvascular resistance as >470 WU.
RESULTS: A total of 153 patients were evaluated; 68 had CMD, and 22 of them showed high microvascular resistance. In patients with CMD, coronary flow reserve was 1.9 ± 0.38 vs 3.2 ± 0.81 in controls (P < 0.001). Lumen volume was significantly correlated with minimal microvascular resistance (r = -0.59 [95% CI: -0.45 to -0.71]; P < 0.001). In patients with CMD and high microvascular resistance, lumen volume was 40% smaller than in controls (512.8 ± 130.3 mm3 vs 853.2 ± 341.2 mm3; P < 0.001). Epicardial lumen volume assessed by coronary CTA was independently associated with minimal microvascular resistance (P < 0.001). The predictive capacity of lumen volume from coronary CTA for detecting high microvascular resistance showed an area under the curve of 0.79 (95% CI: 0.69-0.88).
CONCLUSIONS: Patients with CMD and high minimal microvascular resistance have smaller epicardial vessels than those without CMD. Coronary CTA detected high minimal microvascular resistance with very good diagnostic capacity. Coronary CTA could potentially aid in the diagnostic pathway for patients with ANOCA.
引用
- Collet C, Sakai K, Mizukami T, et al. Vascular Remodeling in Coronary Microvascular Dysfunction. JACC Cardiovasc Imaging. 2024. PMID: 39269414. doi:10.1016/j.jcmg.2024.07.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。