多种影像组学模型鉴别肺部磨玻璃结节中PGL与MIA诊断性能的比较研究
该研究纳入2015年10月至2023年6月经手术病理证实为PGL或MIA的肺部磨玻璃结节116例,按7:3随机分为训练集和验证集,比较临床模型、影像组学模型和联合模型的诊断性能。训练集中联合模型AUC为0.87,高于影像组学模型的0.85;验证集中影像组学模型AUC为0.83,高于联合模型的0.82。影像组学模型准确度和特异度最高,联合模型敏感度最高,但两模型均显著优于临床模型。作者结论认为独立影像组学模型可作为鉴别PGL与MIA的快速无创诊断工具。
要点
- 验证集中影像组学模型AUC为0.83,高于联合模型的0.82
- 影像组学模型准确度和特异度最高,联合模型敏感度最高
- 影像组学模型与联合模型均显著优于临床模型
核心结论
- 独立影像组学模型可作为鉴别肺部磨玻璃结节中PGL与MIA的快速、无创诊断工具。
研究设计与样本
- 回顾性纳入2015年10月至2023年6月经手术病理证实为PGL或MIA的肺部磨玻璃结节116例,按7:3随机分为训练集和验证集,采用ITK-SNAP和Pyradiomics进行分割和影像组学特征提取,建立临床模型、影像组学模型和联合模型,以手术病理为参考标准。
诊断标准与关键数值
- 训练集中联合模型AUC为0.87,影像组学模型AUC为0.85;验证集中影像组学模型AUC为0.83,联合模型AUC为0.82;影像组学模型准确度和特异度最高,联合模型敏感度最高。
临床应用与阅片要点
- 作者结论认为独立影像组学模型可作为鉴别PGL与MIA的快速、无创诊断工具。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Histological subtypes of lung cancers are critical for clinical treatment decision. The aim of this study is to compare the diagnostic performance of multiple radiomics models in differentiating PGL and MIA in pulmonary GGN, in order to identify the most optimal diagnostic model.
MATERIALS AND METHODS: Patients presenting with GGNs on lung CT, confirmed as PGL or MIA through surgical pathology between October 2015 and June 2023, were included. The GGNs were randomly divided into training and validation sets at a 7:3 ratio. Clinical imaging characteristics were analyzed by univariate and multivariate logistic regression to identify independent risk factors for predicting MIA, leading to the development of a clinical model. ITK-SNAP and Pyradiomics were employed for segmentation and radiomics feature extraction. Subsequently, radiomics and combined models were established. The diagnostic performance of the three models was compared using ROC curves and quantitatively assessed by AUC, accuracy, specificity, and sensitivity.
RESULTS: A total of 116 cases of GGNs with pathologically confirmed PGLs and MIAs were included. The clinical model identified three independent predictors. The radiomics model identified seven distinct radiomic features. A combined model was constructed by integrating clinical imaging features with radiomic features. In the training set, the combined model demonstrated a higher AUC than the radiomics model, with AUCs of 0.87 and 0.85 respectively. In the validation set, the radiomics model outperformed the combined model with an AUC of 0.83 versus 0.82. Notably, the radiomics model achieved the highest accuracy and specificity, while the combined model demonstrated the highest sensitivity. However, both models performed significantly better than the clinical model.
CONCLUSION: The independent radiomics model can serve as a rapid, non-invasive diagnostic tool for differentiating between the PGL and MIA.
引用
- Li C, Bao Y, Wang Y, et al. A Comparative Study on the Diagnostic Performance of Multiple Radiomics Models in Differentiating PGL and MIA in Pulmonary Ground-Glass Nodules. Acad Radiol. 2024. PMID: 39306523. doi:10.1016/j.acra.2024.09.022