文献速递骨肌胸部技术与安全CT

人工智能辅助在不同扫描仪采集的计算机断层扫描图像中自动筛查机会性骨质疏松

Artificial intelligence assisted automatic screening of opportunistic osteoporosis in computed tomography images from different scanners.
PubMed 文献 · Eur Radiol · 2024-09-04

基于3312例低剂量胸部CT(2337例训练、975例测试)开发深度学习模型,T1-T12、L1、L2椎体分割平均Dice相似系数95.8%;在3个厂商扫描仪的4401例外部验证数据上以QCT为标准,骨质疏松诊断敏感度>86%、特异度>98%,骨密度平均误差(-0.28, 2.37) mg/cm3。

要点

  • 深度学习模型可在低剂量胸部CT上自动分割椎体并测量骨密度,用于机会性骨质疏松筛查。
  • 以QCT为标准,骨质疏松诊断敏感度>86%、特异度>98%。
  • 模型在不同厂商扫描仪图像上表现良好,且不受患者年龄或性别影响。

核心结论

  • 所开发的工具临床应用可行,有助于椎体定位与分析、骨密度测量以及骨量减少和骨质疏松的筛查。

研究设计与样本

  • 研究为基于低剂量胸部CT的深度学习模型开发与外部验证,训练集2337例、测试集975例,共3312例低剂量胸部CT扫描。
  • 外部验证使用4401例低剂量胸部CT扫描,来自3个不同厂商的扫描仪。
  • 以定量计算机断层扫描(QCT)结果为诊断参考标准,提取T12至L2连续三个椎体的骨密度值。

诊断标准与关键数值

  • 测试数据上T1-T12、L1和L2椎体分割的平均Dice相似系数为95.8%。
  • 与QCT结果相比,模型评估的骨密度平均误差为(-0.28, 2.37) mg/cm3。
  • 骨质疏松诊断的敏感度>86%,特异度>98%。
  • 正常诊断的敏感度总体高于骨量减少或骨质疏松诊断的敏感度。

临床应用与阅片要点

  • 可利用低剂量胸部CT进行机会性骨质疏松筛查,无需额外辐射暴露或费用。
  • 模型在不同厂商扫描仪采集的图像上表现良好,且未显示与患者年龄或性别存在差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: It is feasible to evaluate bone mineral density (BMD) and detect osteoporosis through an artificial intelligence (AI)-assisted system by using quantitative computed tomography (QCT) as a reference without additional radiation exposure or cost.

METHODS: A deep-learning model developed based on 3312 low-dose chest computed tomography (LDCT) scans (trained with 2337 and tested with 975) achieved a mean dice similarity coefficient of 95.8% for T1-T12, L1, and L2 vertebral body (VB) segmentation on test data. We performed a model evaluation based on 4401 LDCT scans (obtained from scanners of 3 different manufacturers as external validation data). The BMD values of all individuals were extracted from three consecutive VBs: T12 to L2. Line regression and Bland‒Altman analyses were used to evaluate the overall detection performance. Sensitivity and specificity were used to evaluate the diagnostic performance for normal, osteopenia, and osteoporosis patients.

RESULTS: Compared with the QCT results as the diagnostic standard, the BMD assessed had a mean error of (- 0.28, 2.37) mg/cm3. Overall, the sensitivity of a normal diagnosis was greater than that of a diagnosis of osteopenia or osteoporosis. For the diagnosis of osteoporosis, the model achieved a sensitivity > 86% and a specificity > 98%.

CONCLUSION: The developed tool is clinically applicable and helpful for the positioning and analysis of VBs, the measurement of BMD, and the screening of osteopenia and osteoporosis.

CLINICAL RELEVANCE STATEMENT: The developed system achieved high accuracy for automatic opportunistic osteoporosis screening using low-dose chest CT scans and performed well on CT images collected from different scanners.

KEY POINTS: Osteoporosis is a prevalent but underdiagnosed condition that can increase the risk of fractures. This system could automatically and opportunistically screen for osteoporosis using low-dose chest CT scans obtained for lung cancer screening. The developed system performed well on CT images collected from different scanners and did not differ with patient age or sex.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wu Y, Yang X, Wang M, et al. Artificial intelligence assisted automatic screening of opportunistic osteoporosis in computed tomography images from different scanners. Eur Radiol. 2024. PMID: 39231830. doi:10.1007/s00330-024-11046-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。