超低剂量光子计数CT检测肺移植后肺部改变的准确性
研究前瞻性纳入82例肺移植受者,比较标准低剂量与两种超低剂量(20%与10%剂量)光子计数CT对肺部异常的检测准确性。结果显示超低剂量方案主观图像质量多可满足诊断,各肺部异常检出准确率多超过70%,除个别读者对近端支气管扩张、支气管壁增厚和空气潴留的检出外;超低剂量方案间噪声、信噪比及读者准确性无显著差异,实现十倍辐射剂量降低。
要点
- 超低剂量光子计数CT在肺移植随访中检出肺部异常可行,辐射剂量约为标准低剂量方案的10%。
- 两种超低剂量方案间噪声(P=0.96)、信噪比(P=0.77)及读者准确性(均P≥0.05)无显著差异。
- 多数肺部异常检出准确率超过70%,但近端支气管扩张、支气管壁增厚和空气潴留的检出在个别读者中低于70%。
核心结论
- 超低剂量光子计数CT用于检测肺移植后肺部异常是可行的,辐射剂量降低十倍。
研究设计与样本
- 前瞻性研究,连续纳入2023年3月至2023年5月同日接受标准低剂量与超低剂量光子计数CT的成年肺移植受者82例(中位年龄64岁,IQR 54-69岁;男性47例),每种超低剂量方案各41例;采用1 mm重建,由三名读者独立评估。
关键影像表现/征象
- 超低剂量图像主观质量在ULD1组39-40例、ULD2组40-41例受者中被认为可诊断(Likert评分≥3)。
- 解剖结构在ULD1组33-41例、ULD2组34-41例受者中可充分显示(Likert评分≥3)。
诊断标准与关键数值
- 平均有效剂量:标准低剂量方案1.41 mSv±0.44,ULD1方案0.26 mSv±0.08,ULD2方案0.17 mSv±0.04。
- 两种超低剂量方案对单个肺部异常的检出准确率均超过70%,但读者1和读者3检测近端支气管扩张、读者3检测支气管壁增厚和空气潴留时除外。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Data on the diagnostic accuracy of ultralow-dose (ULD) CT protocols for periodic surveillance in recipients of lung transplant are lacking. Purpose To assess the potential for radiation dose reduction using ULD photon-counting CT (PCT) to detect lung abnormalities in recipients of lung transplant during repeat CT follow-up. Materials and Methods Consecutive adult recipients of lung transplant undergoing same-day standard-of-care low-dose (LD) and ULD PCT from March 2023 to May 2023 were prospectively included. The ULD protocols were performed with two target effective doses comprising 20% (hereafter, ULD1) and 10% (hereafter, ULD2) of the standard LD protocol. The 1-mm reconstructions were reviewed by three readers. Subjective image quality, the visibility of certain anatomic structures (using a five-point Likert scale), and the presence of lung abnormalities were independently assessed. The χ2 or t tests were used to evaluate differences between the ULD1 and ULD2 protocols. Results A total of 82 participants (median age, 64 years [IQR, 54-69 years]; 47 male) were included (41 participants for each ULD protocol). The mean effective doses per protocol were 1.41 mSv ± 0.44 (SD) for LD, 0.26 mSv ± 0.08 for ULD1, and 0.17 mSv ± 0.04 for ULD2. According to three readers, the subjective image quality of the ULD images was deemed diagnostic (Likert score ≥3) in 39-40 (ULD1) and 40-41 (ULD2) participants, and anatomic structures could be adequately visualized (Likert score ≥3) in 33-41 (ULD1) and 34-41 (ULD2) participants. The detection accuracy for individual lung anomalies exceeded 70% for both ULD protocols, except for readers 1 and 3 detecting proximal bronchiectasis and reader 3 detecting bronchial wall thickening and air trapping. No evidence of a statistically significant difference in noise (P = .96), signal-to-noise ratio (P = .77), or reader accuracy (all P ≥ .05) was noted between the ULD protocols. Conclusion ULD PCT was feasible for detecting lung abnormalities following lung transplant, with a tenfold radiation dose reduction. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ciet in this issue.
引用
- Milos RI, Lechner L, Korajac A, et al. Accuracy of Ultralow-Dose Photon-counting CT in the Detection of Lung Changes after Lung Transplant. Radiology. 2024. PMID: 39254452. doi:10.1148/radiol.240271
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。