光子计数探测器CT生成的碘图用于表征肺实质病变:一项可行性研究
该可行性研究纳入325例接受光子计数CT扫描并使用肺实质对比剂的患者,将206个确诊病灶分为实变、磨玻璃影和网状三种基本模式,由放射科医师在有无碘图条件下以5点Likert量表评估诊断信心。纳入碘图后三种模式的平均Likert评分均显著提高(实变3.3 vs 3.9,磨玻璃影3.4 vs 4.1,网状3.6 vs 4.4,p<0.001),29个病灶的分类发生改变。作者结论认为碘图提供对比剂摄取信息并提高放射科医师表征肺实质病变的诊断信心。
要点
- 纳入碘图后实变、磨玻璃影、网状模式的诊断信心评分均显著提高(p<0.001)。
- 29个病灶在纳入碘图后分类发生改变,提示碘图可补充形态学重叠病灶的信息。
- 磨玻璃影3例和网状1例评分被下调,见于形态不确定的磨玻璃影及碘摄取不均匀的肺不张。
核心结论
- 纳入碘图可增加对比剂摄取信息,提高放射科医师表征肺实质病变的诊断信心;碘图有潜力为形态重叠的肺阴影判读提供补充信息。
研究设计与样本
- 可行性研究,325例患者使用光子计数CT以四种扫描方案扫描,均使用肺实质对比剂;病灶由3名放射科医师中的2名在不知诊断的情况下分类,使用5点Likert量表分别在有无碘图条件下进行两次分类,意见不一致时咨询第三名读者并以共识决定。
关键影像表现/征象
- 共发现206个有确诊诊断的病灶,包括83个实变、72个磨玻璃影和51个网状模式。
- 纳入碘图后,实变、磨玻璃影和网状三种基本模式的平均Likert评分均显著提高(p<0.001)。
- 磨玻璃影3例和网状模式1例的评分被下调,分别见于形态不确定的磨玻璃影(3例)和碘摄取不均匀的肺不张(1例)。
- 29个病灶在纳入碘图后分类发生改变。
诊断标准与关键数值
- 病灶分为实变、磨玻璃影和网状三种基本模式,由2名放射科医师在不知诊断的情况下分类,意见不一致时咨询第三名读者并以共识决定。
- 诊断信心使用5点Likert量表评估,分别在有无碘图条件下进行两次分类。
- 纳入碘图后平均Likert评分:实变3.3 vs 3.9,磨玻璃影3.4 vs 4.1,网状3.6 vs 4.4,p<0.001。
临床应用与阅片要点
- 在光子计数CT肺实质对比扫描中,碘图可常规用于辅助判读肺实质病变,以提高诊断信心。
- 对形态学重叠的肺阴影,可结合碘图提供的对比剂摄取信息辅助分类。
- 形态不确定的磨玻璃影及碘摄取不均匀的肺不张可能出现评分下调,判读时需注意。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: With photon-counting CT, spectral imaging is always available, and iodine maps with high spatial and spectral resolution can be generated.
OBJECTIVES: The aim of this study was to investigate whether iodine uptake in different parenchymal patterns can be used to characterise parenchymal disease with increased lung attenuation.
METHODS: 325 patients were scanned with a photon-counting CT using four scan protocols, all with lung parenchymal contrast. Lesions were classified into three basic patterns: consolidation, ground-glass opacities (GGO), and reticular pattern. Lesion classification was performed by 2 of 3 radiologists who were blinded to the diagnosis. Classification was performed twice using a 5-point Likert scale (with and without iodine maps). In case of disagreement, a third reader was consulted, and the decision was made by consensus.
RESULTS: 206 lesions were found with a confirmed diagnosis (83 consolidations, 72 GGO, and 51 reticular). Diagnostic confidence improved when iodine maps were included in the evaluation. The mean Likert score increased significantly for all three basic patterns (consolidations: 3.3 vs. 3.9, GGO: 3.4 vs. 4.1, and reticular: 3.6 vs. 4.4, p < 0.001). However, the score for GGO and reticular pattern was downgraded in three and one cases, respectively. The downgrading occurred for morphologically uncertain GGO findings (3) and atelectasis (1) with inhomogeneous iodine uptake. In 29 lesions, the classification was changed when the iodine maps were included in the evaluation.
CONCLUSION: Including iodine maps adds contrast uptake information and improves the diagnostic confidence of radiologists in the characterization of parenchymal pathologies.
CLINICAL IMPACT: Iodine maps have the potential to provide complementary information for the interpretation of lung opacities with overlapping morphology.
引用
- Huisinga C, Bredemeier S, Hartung D, et al. Photon-counting detector CT (PCD-CT) generated iodine maps to characterize parenchymal lung disease: A feasibility study. Eur J Radiol. 2024. PMID: 39241302. doi:10.1016/j.ejrad.2024.111689
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。