文献速递神经技术与安全MR

基于人工智能的三维T1 MRI容积分析自动诊断特发性正常压力脑积水

Automated Idiopathic Normal Pressure Hydrocephalus Diagnosis via Artificial Intelligence-Based 3D T1 MRI Volumetric Analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-01-08

本研究利用452例训练集和110例测试集的三维T1加权脑MRI,开发自动测量Evans指数、外侧裂扩大、高凸面紧贴、胼胝体角及标准化侧脑室体积的算法,并用XGBoost模型预测特发性正常压力脑积水。自动测量高凸面紧贴的AUC为0.956,外侧裂扩大为0.830;全自动模型在测试集AUC为0.936,手动标签模型为0.938。作者认为该机器学习算法能从三维T1加权MRI诊断特发性正常压力脑积水,并可用于大规模筛查。

要点

  • 自动测量高凸面紧贴的AUC达0.956,外侧裂扩大为0.830。
  • 全自动XGBoost模型在未见测试集上AUC为0.936。
  • 手动标签模型测试集AUC为0.938,与全自动模型接近。

核心结论

  • 机器学习算法能从三维T1加权MRI诊断特发性正常压力脑积水,且对扫描失败具有鲁棒性,作者提出可在极少人工干预下扫描大量三维T1加权MRI,实现大规模特发性正常压力脑积水筛查。

研究设计与样本

  • 研究使用452例训练集和110例测试集的三维T1加权脑MRI扫描,纳入特发性正常压力脑积水、帕金森病、阿尔茨海默病和健康对照,开发自动测量Evans指数、外侧裂扩大、高凸面紧贴、胼胝体角和标准化侧脑室体积的算法,并训练XGBoost模型进行特发性正常压力脑积水预测。

诊断标准与关键数值

  • 自动测量高凸面紧贴的AUC为0.956,外侧裂扩大的AUC为0.830;胼胝体角的组内相关系数为0.824,Evans指数的组内相关系数为0.924;手动标签训练的XGBoost模型训练集交叉验证平均AUC为0.988、未见测试集AUC为0.938,全自动模型交叉验证AUC为0.983、未见测试集AUC为0.936。

临床应用与阅片要点

  • 作者提出一种可在极少人工干预下扫描大量三维T1加权MRI的方法,使大规模特发性正常压力脑积水筛查成为可能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Idiopathic normal pressure hydrocephalus (iNPH) is reversible dementia that is underdiagnosed. The purpose of this study was to develop an automated diagnostic method for iNPH using artificial intelligence techniques with a T1-weighted MRI scan.

MATERIALS AND METHODS: We quantified iNPH, Parkinson disease, Alzheimer disease, and healthy controls on T1-weighted 3D brain MRI scans using 452 scans for training and 110 scans for testing. Automatic component measurement algorithms were developed for the Evans index, Sylvian fissure enlargement, high-convexity tightness, callosal angle, and normalized lateral ventricle volume. XGBoost models were trained for both automated measurements and manual labels for iNPH prediction.

RESULTS: A total of 452 patients (200 men; mean age, 73.2 [SD, 6.5] years) were included in the training set. Of the 452 patients, 111 (24.6%) had iNPH. We obtained area under the curve (AUC) values of 0.956 for automatically measured high-convexity tightness and 0.830 for Sylvian fissure enlargement. Intraclass correlation values of 0.824 for the callosal angle and 0.924 for the Evans index were measured. By means of the decision tree of the XGBoost model, the model trained on manual labels obtained an average cross-validation AUC of 0.988 on the training set and 0.938 on the unseen test set, while the fully automated model obtained a cross-validation AUC of 0.983 and an unseen test AUC of 0.936.

CONCLUSIONS: We demonstrated a machine learning algorithm capable of diagnosing iNPH from a 3D T1-weighted MRI that is robust to the failure. We propose a method to scan large numbers of 3D T1-weighted MRIs with minimal human intervention, making possible large-scale iNPH screening.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Lee J, Kim D, Suh CH, et al. Automated Idiopathic Normal Pressure Hydrocephalus Diagnosis via Artificial Intelligence-Based 3D T1 MRI Volumetric Analysis. AJNR Am J Neuroradiol. 2025. PMID: 39251255. doi:10.3174/ajnr.A8489

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。