利用定量磁化率图鉴别钙化与脑微出血
本研究基于3-T MR采集的磁敏感加权成像数据生成定量磁化率图(QSM),并与CT定位的松果体及脉络丛钙化对照,共分析232个低信号灶(121个脑微出血、111个钙化)。钙化平均磁化率为-214±112 ppb,脑微出血为392±204 ppb,仅凭磁化率符号即可鉴别(p<0.001);深部脑微出血磁化率高于脑叶脑微出血。
要点
- QSM上磁化率符号即可区分钙化(负值)与脑微出血(正值)。
- 钙化平均磁化率-214±112 ppb,脑微出血392±204 ppb,差异有统计学意义(p<0.001)。
- 深部脑微出血磁化率499±220 ppb,高于脑叶脑微出血的299±133 ppb(p<0.001)。
核心结论
- 磁化率符号足以鉴别钙化与脑微出血,且磁化率数值本身可反映钙或铁的浓度;深部脑微出血平均磁化率高于脑叶脑微出血。
研究设计与样本
- 利用3-T MR扫描仪采集的磁敏感加权成像数据生成QSM,共选取232个低信号灶(121个脑微出血、111个钙化),先用CT定位松果体与脉络丛钙化,再以QSM评估所有病灶的磁化率。
关键影像表现/征象
- QSM数据中共选取232个低信号灶,其中121个为脑微出血、111个为钙化。
- 钙化平均磁化率为-214±112 ppb,脑微出血平均磁化率为392±204 ppb。
- 全部脑微出血磁化率最小值为75 ppb,全部钙化磁化率最大值为-52 ppb。
- 脑微出血中,脑叶皮质下白质者磁化率为299±133 ppb,基底节、丘脑及脑干深部者为499±220 ppb。
诊断标准与关键数值
- 仅凭磁化率符号即可清晰鉴别钙化与脑微出血(p<0.001)。
- 全部脑微出血磁化率最小值为75 ppb,全部钙化磁化率最大值为-52 ppb,可作为两类病灶的数值参考。
- 深部脑微出血与脑叶脑微出血的磁化率差异有统计学意义(p<0.001)。
临床应用与阅片要点
- 阅片时可利用QSM上磁化率的正负符号区分钙化与脑微出血。
- 磁化率数值本身可用于判断钙或铁的浓度。
- 深部脑微出血的平均磁化率高于脑叶脑微出血。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To differentiate cerebral microbleeds (CMBs) and calcifications using quantitative susceptibility mapping (QSM).
METHODS: CMBs were visualized and located using QSM from susceptibility-weighted imaging data collected on a 3-T MR scanner. Calcifications of the pineal gland and the choroid plexus were localized first using CT. All calcifications and CMBs were assessed using QSM to evaluate their magnetic susceptibility. The distribution of the magnetic susceptibility for the CMBs was determined and the CT attenuation was correlated with the mean magnetic susceptibility for the calcifications.
RESULTS: A total of 232 hypointense foci were selected from the QSM data: 121 were CMBs and 111 were calcifications. The mean magnetic susceptibility was -214 ± 112 ppb for the calcifications and 392 ± 204 ppb for the CMBs. The minimum value of magnetic susceptibility was 75 ppb for all the CMBs and the maximum value was -52 ppb for all the calcifications. The calcifications were clearly differentiable from the CMBs from the sign alone (p < 0.001). The magnetic susceptibility for the CMBs was 299 ± 133 ppb in the lobar subcortical white matter and 499 ± 220 ppb for deep CMBs in the basal ganglia, thalamus, and brainstem. There was a significant difference in the susceptibility between these two regions (p < 0.001).
CONCLUSION: The sign of the magnetic susceptibility was sufficient to differentiate calcifications and CMBs. The concentration of calcium or iron can be determined from the susceptibility value itself. The deep CMBs had higher susceptibility on average than lobar bleeds.
CLINICAL RELEVANCE STATEMENT: This study's ability to differentiate between CMBs and calcifications using QSM could enhance diagnostic accuracy, guiding more precise treatment decisions for stroke or tumor patients.
KEY POINTS: The sign of magnetic susceptibility is sufficient to differentiate calcifications and CMBs. QSM can successfully differentiate calcifications from microbleeds. The concentration of calcium or iron can be determined from the susceptibility value itself.
引用
- Luo Y, Gao K, Zhou Y, et al. Differentiating calcifications from cerebral microbleeds using quantitative susceptibility mapping. Eur Radiol. 2024. PMID: 39285029. doi:10.1007/s00330-024-10889-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。