使用全脑三维磁共振波谱与回波平面时间分辨成像对胶质瘤患者和健康人进行绝对代谢物定量

Absolute Metabolite Quantification in Individuals with Glioma and Healthy Individuals Using Whole-Brain Three-dimensional MR Spectroscopic and Echo-planar Time-resolved Imaging.
PubMed 文献 · Radiology · 2024-01-01

这项前瞻性研究于2022年8月至2023年8月开展,将全脑磁共振波谱成像(MRSI)与回波平面时间分辨成像(EPTI)弛豫测量相结合,以内部水为浓度参考对代谢物浓度进行快速绝对定量,并与使用人群平均文献弛豫值的传统方法比较。结果显示,健康人两种方法一致性良好(偏倚+4%),而胶质瘤患者两种方法差异较大(偏倚+39%),所提方法提高了总N-乙酰天冬氨酸、总胆碱和总肌酸的肿瘤对比噪声比。

要点

  • 全脑MRSI-EPTI可在约8分钟MRSI加3分钟EPTI内实现2.4 mm各向同性分辨率的代谢物绝对定量。
  • 健康人两种定量方法偏倚+4%(CI±26%),胶质瘤患者偏倚+39%(CI±55%)。
  • 所提方法使总N-乙酰天冬氨酸、总胆碱和总肌酸的肿瘤对比噪声比中位数均升高(P=.03)。

核心结论

  • 全脑MRSI-EPTI方法以个体化校正实现2.4 mm各向同性分辨率的快速绝对定量,在疾病状态下所得浓度较传统文献校正更接近真实值。

研究设计与样本

  • 前瞻性研究,2022年8月至2023年8月,纳入6名健康参与者(4名男性,平均年龄37岁±11)和9名胶质瘤参与者(6名男性,平均年龄41岁±15;1例IDH1野生型,8例IDH1突变型),在3 T下用32通道线圈成像,以内部水为浓度参考。

关键影像表现/征象

  • 实时导航绝热螺旋三维MRSI扫描约8分钟采集,经超分辨率重建获得2.4 mm各向同性分辨率的脑代谢图像。
  • 高空间分辨率多参数EPTI扫描3分钟、1 mm各向同性分辨率,用于校正水参考信号的弛豫和质子密度。

诊断标准与关键数值

  • 健康参与者中两种方法代谢物浓度一致性良好,偏倚+4%,CI±26%。
  • 胶质瘤参与者中两种方法差异较大,偏倚+39%,CI±55%。
  • 肿瘤对比噪声比(中位数):总N-乙酰天冬氨酸EPTI 0.541(95%CI 0.217, 0.910)vs 传统0.484(95%CI 0.199, 0.823)。
  • 肿瘤对比噪声比(中位数):总胆碱EPTI 1.053(95%CI 0.681, 1.713)vs 传统0.940(95%CI 0.617, 1.295)。
  • 肿瘤对比噪声比(中位数):总肌酸EPTI 0.745(95%CI 0.628, 0.909)vs 传统0.553(95%CI 0.444, 0.828);上述三项P=.03。

临床应用与阅片要点

  • 定量代谢物浓度时以内部水为参考,并用个体化EPTI弛豫测量校正水参考信号,替代人群平均文献弛豫值。
  • 在胶质瘤等改变组织水水平的病变中,传统文献弛豫校正的绝对浓度偏差较大(偏倚+39%),解读时需结合所用校正方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: MR spectroscopic imaging (MRSI) can be used to quantify an extended brain metabolic profile but is confounded by changes in tissue water levels due to disease.

PURPOSE: To develop a fast absolute quantification method for metabolite concentrations combining whole-brain MRSI with echo-planar time-resolved imaging (EPTI) relaxometry in individuals with glioma and healthy individuals.

MATERIALS AND METHODS: In this prospective study performed from August 2022 to August 2023, using internal water as concentration reference, the MRSI-EPTI quantification method was compared with the conventional method using population-average literature relaxation values. Healthy participants and participants with mutant IDH1 gliomas underwent imaging at 3 T with a 32-channel coil. Real-time navigated adiabatic spiral three-dimensional MRSI scans were acquired in approximately 8 minutes and reconstructed with a super-resolution pipeline to obtain brain metabolic images at 2.4-mm isotropic resolution. High-spatial-resolution multiparametric EPTI was performed in 3 minutes, with 1-mm isotropic resolution, to correct the relaxation and proton density of the water reference signal. Bland-Altman analysis and the Wilcoxon signed rank test were used to compare absolute quantifications from the proposed and conventional methods.

RESULTS: Six healthy participants (four male; mean age, 37 years ± 11 [SD]) and nine participants with glioma (six male; mean age, 41 years ± 15; one with wild-type IDH1 and eight with mutant IDH1) were included. In healthy participants, there was good agreement (+4% bias) between metabolic concentrations derived using the two methods, with a CI of plus or minus 26%. In participants with glioma, there was large disagreement between the two methods (+39% bias) and a CI of plus or minus 55%. The proposed quantification method improved tumor contrast-to-noise ratio (median values) for total N-acetyl-aspartate (EPTI: 0.541 [95% CI: 0.217, 0.910]; conventional: 0.484 [95% CI: 0.199, 0.823]), total choline (EPTI: 1.053 [95% CI: 0.681, 1.713]; conventional: 0.940 [95% CI: 0.617, 1.295]), and total creatine (EPTI: 0.745 [95% CI: 0.628, 0.909]; conventional: 0.553 [95% CI: 0.444, 0.828]) (P = .03 for all).

CONCLUSION: The whole-brain MRSI-EPTI method provided fast absolute quantification of metabolic concentrations with individual-specific corrections at 2.4-mm isotropic resolution, yielding concentrations closer to the true value in disease than the conventional literature-based corrections. © RSNA, 2024 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。