文献速递神经外周血管MR

人工智能可辅助在常规脑MRI的TOF MRA数据集上检出偶发颅内动脉瘤并缩短图像分析时间

Artificial intelligence can help detecting incidental intracranial aneurysm on routine brain MRI using TOF MRA data sets and improve the time required for analysis of these images.
PubMed 文献 · Neuroradiology · 2024-09-04

本研究评估商用AI软件检测颅内动脉瘤的诊断性能,并判断其能否提高放射科医生识别动脉瘤的准确性、缩短图像分析时间。在500例TOF-MRA脑检查中,联合AI与神经放射科医生读数共检出85例检查中的106个动脉瘤;神经放射科医生检出98个动脉瘤(敏感度92.5%),AI检出77个动脉瘤(敏感度72.6%),AI整合使TOF-MRA分析时间减少19秒(降低23%)。

要点

  • 联合AI与神经放射科医生读数共检出85例检查中的106个动脉瘤。
  • 神经放射科医生敏感度92.5%,AI软件敏感度72.6%。
  • AI整合使TOF-MRA分析时间减少19秒(降低23%)。

核心结论

  • AI软件可辅助神经放射科医生解读脑TOF-MRA;联合读数较单独神经放射科医生或单独软件读数在识别颅内动脉瘤方面可靠性更高,从而提高神经放射科医生的诊断准确性,同时使阅片时间缩短约四分之一。

研究设计与样本

  • 研究纳入500例TOF-MRA临床脑检查,使用商用软件与一名神经放射科顾问医生分析颅内动脉瘤,以联合AI与神经放射科医生读数为参考标准,计算软件与神经放射科医生的敏感度和特异度,并比较使用与不使用AI软件时神经放射科医生分析TOF-MRA图像集所需时间。

诊断标准与关键数值

  • 神经放射科医生检出98个动脉瘤,敏感度92.5%。
  • AI软件检出77个动脉瘤,敏感度72.6%。
  • 联合AI与神经放射科医生读数共检出85例检查中的106个动脉瘤,并以此联合结果为参考标准计算敏感度和特异度。

临床应用与阅片要点

  • 作者认为AI软件可支持神经放射科医生解读脑TOF-MRA。
  • 作者认为联合AI软件与神经放射科医生读数在识别颅内动脉瘤方面较单独神经放射科医生或单独软件读数可靠性更高,可提高诊断准确性。
  • AI整合使神经放射科医生TOF-MRA分析时间减少19秒(降低23%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of our study was to assess the diagnostic performance of commercially available AI software for intracranial aneurysm detection and to determine if the AI system enhances the radiologist's accuracy in identifying aneurysms and reduces image analysis time.

METHODS: TOF-MRA clinical brain examinations were analyzed using commercially available software and by an consultant neuroradiologist for the presence of intracranial aneurysms. The results were compared with the reference standard, to measure the sensitivity and specificity of the software and the consultant neuroradiologist. Furthermore, we examined the time required for the neuroradiologist to analyze the TOF-MRA image set, both with and without use of the AI software.

RESULTS: In 500 TOF-MRI brain studies, 106 aneurysms were detected in 85 examinations by combining AI software with neuroradiologist readings. The neuroradiologist identified 98 aneurysms (92.5% sensitivity), while AI detected 77 aneurysms (72.6% sensitivity). Specificity and sensitivity were calculated from the combined effort as reference. Combining AI and neuroradiologist readings significantly improves detection reliability. Additionally, AI integration reduced TOF-MRA analysis time by 19 s (23% reduction).

CONCLUSIONS: Our findings indicate that the AI-based software can support neuroradiologists in interpreting brain TOF-MRA. A combined reading of the AI-based software and the neuroradiologist demonstrated higher reliability in identifying intracranial aneurysms as compared to reading by either neuroradiologist or software, thus improving diagnostic accuracy of the neuroradiologist. Simultaneously, reading time for the neuroradiologist was reduced by approximately one quarter.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Adamchic I, Kantelhardt SR, Wagner HJ, et al. Artificial intelligence can help detecting incidental intracranial aneurysm on routine brain MRI using TOF MRA data sets and improve the time required for analysis of these images. Neuroradiology. 2024. PMID: 39230716. doi:10.1007/s00234-024-03460-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。