指南与共识胸部CT

基于美国国家综合癌症网络指南的低剂量CT肺癌筛查中亚实性结节随访推荐观察者间一致性研究

Inter-observer consistency on subsolid nodule follow-up recommendation based on National Comprehensive Cancer Network (NCCN) guidelines in low-dose computed tomography (LDCT) lung cancer screening.
指南 / 共识 · Quant Imaging Med Surg · 2024-08-28

该研究回顾性收集2014至2017年低剂量CT肺癌筛查中含亚实性结节的110例报告,纳入60例扫描由5名观察者按NCCN指南进行随访推荐分组。5名观察者总体准确率72.3%,总体一致性中等(Fleiss kappa=0.437),胸部放射科医师一致性显著高于放射科住院医师(P<0.01)。不一致病例中73.5%与同一风险主导结节相关,部分实性结节比例较高是不一致的风险因素。

要点

  • 按NCCN指南对亚实性结节进行随访推荐分组时,5名观察者总体一致性仅为中等(Fleiss kappa=0.437)。
  • 胸部放射科医师一致性达显著水平(Cohen kappa=0.655),显著高于放射科住院医师(P<0.01)。
  • 不一致病例中73.5%源于同一风险主导结节的测量和类型判断分歧,部分实性结节比例较高是不一致风险因素。

核心结论

  • 基于NCCN指南对亚实性结节进行随访推荐分类评估,观察者间一致性为中等;不一致主要由同一风险主导结节的测量和类型判断分歧引起,部分实性结节是不一致的促成因素,配对评估中主要和实质性管理不一致分别为27.5%和4.8%。

研究设计与样本

  • 回顾性研究,通过放射信息系统和关键词搜索收集2014至2017年肺癌筛查的低剂量CT报告,共识别110例含亚实性结节的低剂量CT病例。

诊断标准与关键数值

  • 5名观察者随访推荐总体准确率为72.3%;总体一致性中等,Fleiss kappa为0.437;所有配对读者平均Cohen kappa值为0.603(95%CI:0.489-0.716);胸部放射科医师Cohen kappa为0.655(95%CI:0.503-0.807),达显著一致性;放射科住院医师平均Cohen kappa为0.533(95%CI:0.501-0.565);600次配对判读中,主要不一致和实质性不一致分别占27.5%和4.8%(29/600)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Follow-up management of pulmonary nodules is a crucial component of lung cancer screening. Consistency in follow-up recommendations is essential for effective lung cancer screening. This study aimed to assess inter-observer agreement on National Comprehensive Cancer Network (NCCN) guideline-based follow-up recommendation for subsolid nodules from low-dose computed tomography (LDCT) screening.

METHODS: A retrospective collection of LDCT reports from 2014 to 2017 for lung cancer screening was conducted using the Radiology Information System and keyword searches, focusing on subsolid nodules. A total of 110 LDCT cases containing subsolid nodules were identified. Two senior radiologists provided standardized follow-up recommendation. Follow-up recommendation was categorized into four groups (0-, 3-, 6-, and 12-month). To ensure overall balance and representativeness of the follow-up categories, 60 scans from 60 participants were included (distribution ratio 1:1:2:2). Cases were categorised into follow-up recommendation groups by five observers following NCCN guidelines. Fleiss' kappa statistic was used to evaluate inter-observer agreement.

RESULTS: Overall accuracy rate for follow-up recommendation among five observers was 72.3%. Chest radiologists' overall agreement was significantly higher than radiology residents (P<0.01). The overall agreement among the five observers was moderate, with a Fleiss' kappa of 0.437. For all paired readers, the mean Cohen's kappa value was 0.603, with 95% confidence interval (CI) from 0.489 to 0.716. Chest radiologists demonstrated substantial agreement, evidenced by a Cohen's kappa of 0.655 (95% CI: 0.503-0.807). In contrast, the mean Cohen's kappa among radiology residents was 0.533 (95% CI: 0.501-0.565). The majority of cases with discrepancies, accounting for 73.5%, were associated with the same risk-dominant nodules. A higher proportion of part-solid nodule was a risk factor for discrepancies. Of the 600 paired readings, major discrepancies and substantial discrepancies were observed in 27.5% and 4.8% (29/600) of the cases.

CONCLUSIONS: In subsolid nodules, category evaluation of observer follow-up recommendation based on NCCN guidelines achieved moderate consistency. Disagreements were mainly caused by measurement and type disagreements of identical risk-dominant nodules. Part-solid nodule was a contributor for discrepancies in follow-up recommendation. Major and substantial management discrepancies were 27.5% and 4.8% in the paired evaluations.

来源:Quant Imaging Med Surg,查看原文。版权归原作者所有。

引用

  1. Wu Q, Zhou L, Tang W, et al. Inter-observer consistency on subsolid nodule follow-up recommendation based on National Comprehensive Cancer Network (NCCN) guidelines in low-dose computed tomography (LDCT) lung cancer screening. Quant Imaging Med Surg. 2024. PMID: 39281119. doi:10.21037/qims-23-1824

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。