标准剂量与增加鞘内碘对比剂剂量行双侧侧卧位CT脊髓造影的安全性及技术性能比较

Safety and Technical Performance of Bilateral Decubitus CT Myelography Using Standard versus Increased Intrathecal Iodinated Contrast Volume.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-02-03

该回顾性系列纳入24例接受侧卧位CT脊髓造影的患者,分别鞘内注射10 mL或20 mL碘对比剂(碘浓度300或320 mg/mL),同次检查中先行初始侧卧位扫描,再翻转至对侧复查。20 mL组未记录中度或重度不良事件,且第二侧扫描的衰减值在统计学上高于标准剂量组;作者认为增加鞘内对比剂剂量耐受良好并改善了技术性能,但需更大样本进一步评估安全性及对诊断率的影响。

要点

  • 20 mL组与10 mL组均未记录中度或重度不良事件。
  • 20 mL组第二侧扫描的衰减值在统计学上高于标准剂量组。
  • 作者认为增加鞘内对比剂剂量耐受良好并改善技术性能,但需更大样本进一步评估。

核心结论

  • 增加鞘内对比剂剂量在本有限系列中耐受良好,并改善了侧卧位CT脊髓造影的技术性能;需更大患者队列进一步评估安全性及对诊断率的影响。

研究设计与样本

  • 回顾性系列,24例患者接受侧卧位CT脊髓造影,鞘内注射10 mL或20 mL碘对比剂(碘浓度300或320 mg/mL),同次检查中先行初始侧卧位扫描,再翻转至对侧复查。

诊断标准与关键数值

  • 通过测量标准化层面侧方硬膜囊的衰减值比较10 mL组与20 mL组的技术性能,初始扫描与翻转至对侧后的扫描均予评估。
  • 20 mL组第二侧扫描的衰减值在统计学上高于标准剂量组。

局限性

  • 本文为有限系列(limited series)。
  • 作者结论指出需使用更大患者队列进一步评估安全性及对诊断率的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Lateral decubitus CT myelography (LDCTM) is one of the main studies for the detection of CSF-venous fistulas, but detection of CSF-venous fistulas is dependent on intrathecal contrast attenuation. The purpose of this investigation was to assess the tolerability and technical performance of increased intrathecal doses of myelographic contrast compared with standard doses.

MATERIALS AND METHODS: This is a retrospective series of 24 patients who underwent LDCTM following administration of either 10 or 20 mL of intrathecal iodinated contrast media (300 or 320 mg/mL of iodine content). Patients were scanned in the initial lateral decubitus position and then turned to the contralateral side and re-scanned in the same session. The safety and tolerability of the 20 mL dose was assessed from clinical records. The technical performance of the studies was compared between groups (10 or 20 mL) by measuring attenuation values over the lateral thecal sac at standardized levels. Both the initial scan and the scan after turning the patient to the contralateral side were assessed.

RESULTS: No moderate or severe adverse event was recorded in either group. The 20-mL group showed higher attenuation values, which were statistically greater on the second side examined compared with the standard-dose group.

CONCLUSIONS: Increased volume of intrathecal contrast was well-tolerated and improved the technical performance of LDCTM in this limited series. Further assessment of the safety and impact on diagnostic yield using larger patient cohorts is warranted.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。