文献速递介入外周血管心血管DSA

介入放射学与介入心脏病学操作中使用的7种碘对比剂黏附性比较

Stickiness of 7 types of iodinated contrast media used during interventional radiology and interventional cardiology procedures.
PubMed 文献 · Eur J Radiol · 2024-08-18

该研究采用探针黏附测试比较7种常用碘对比剂在手术手套间的黏附性,以分离所需功(mJ)衡量。结果显示黏附性从低到高依次为Hexabrix 320、Visipaque 270、Visipaque 320、Iomeron 300、Xenetix 300、Ultravist 300、Omnipaque 300,黏附性最低的四种与其余三种差异有统计学意义(P=0.000-0.004)。作者认为Omnipaque 300、Ultravist 300和Xenetix 300黏附性最强,可能在操作中造成最大实际问题;Hexabrix 320、Visipaque 270和Visipaque 320黏附性最低,可能有助于限制黏附所致并发症。

要点

  • 7种碘对比剂黏附功均值从低到高:Hexabrix 320为0.70 mJ,Omnipaque 300为8.14 mJ。
  • 黏附性最低的四种(Hexabrix 320、Visipaque 270、Visipaque 320、Iomeron 300)与其余三种差异有统计学意义(P=0.000-0.004)。
  • 作者认为Omnipaque 300、Ultravist 300和Xenetix 300黏附性最强,可能造成最大实际操作问题。

核心结论

  • 市售碘对比剂之间存在显著且可重复的黏附性差异,Hexabrix 320、Visipaque 270、Visipaque 320和Iomeron 300黏附性最低。

研究设计与样本

  • 采用探针黏附测试比较7种碘对比剂:Xenetix 300、Hexabrix 320、Ultravist 300、Visipaque 270、Omnipaque 300、Visipaque 320和Iomeron 300;将手术手套碎片之间加入0.1 ml碘对比剂后于计算机控制下拉开,以分离探针所需功衡量黏附性。

诊断标准与关键数值

  • 黏附性以分离探针所需功(mJ)衡量,均值(范围)从低到高:Hexabrix 320为0.70(0.16-1.23)、Visipaque 270为1.18(0.47-1.89)、Visipaque 320为1.70(0.59-2.81)、Iomeron 300为3.01(1.82-4.20)、Xenetix 300为5.83(3.96-7.69)、Ultravist 300为5.83(2.83-8.84)、Omnipaque 300为8.14(6.95-9.33)。

临床应用与阅片要点

  • 作者认为Omnipaque 300、Ultravist 300和Xenetix 300黏附性最强,可能在操作中造成最大实际问题;Hexabrix 320、Visipaque 270和Visipaque 320黏附性最低,可能有助于限制黏附所致并发症。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: During Interventional Cardiology (IC) and Interventional Radiology (IR) procedures operators' gloves, guide wires and catheters may stick together due to the inherent stickiness of Iodine Containing Contrast Media (ICCM). This may result in displacement of materials, compromising technical success. In this study we compare the stickiness of seven frequently used types of ICCM.

MATERIAL AND METHODS: Xenetix 300, Hexabrix 320 (Guerbet, Villepinte, France), Ultravist 300 (Bayer, Leverkusen, Germany), Visipaque 270, Omnipaque 300, Visipaque 320 (GE, Wauwatosa, WI) and Iomeron300 (Bracco, Milano, Italy) are compared using a probe-tack test. Pieces of surgical gloves are put together with 0.1 ml of of ICCM in between, and subsequently pulled apart under computer control. Stickiness is measured as the work needed to separate the probes.

RESULTS: From least to most sticky results were: Hexabrix 320 (mean Work (mJ); range: 0.70; 0.16-1.23), Visipaque 270 (1.18; 0.47-1.89), Visipaque 320 (1.70; 0.59-2.81), Iomeron 300 (3.01; 1.82-4.20), Xenetix 300 (5.83; 3.96-7.69), Ultravist 300 (5.83; 2.83-8.84), Omnipaque 300 (8.14; 6.95-9.33). The four least sticky ICCM differ statistically significantly (p = 0.000-0.004) from the remaining. In this research Omnipaque 300, Ultravist 300 and Xenetix 300 are the stickiest and may hence pose the greatest practical problems during procedures; in contrast, Hexabrix 320, Visipaque 270 and Visipaque 320 are the least sticky in this research and may therefore aid in constraining complications caused by stickiness.

CONCLUSION: A significant and reproducible difference in stickiness exists between commercially available ICCM, Hexabrix 320, Visipaque 270, Visipaque 320 and Iomeron 300, being least sticky.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Schreinemakers JBS, Sprik R, Vos JA, et al. Stickiness of 7 types of iodinated contrast media used during interventional radiology and interventional cardiology procedures. Eur J Radiol. 2024. PMID: 39213761. doi:10.1016/j.ejrad.2024.111645

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。