文献速递神经外周血管技术与安全CT

稀释对比剂试验团注联合个体化对比剂方案用于头颈动脉双低剂量CT血管成像

Double low-dose computed tomography (CT) angiography of craniocervical arteries using a test bolus of diluted contrast medium and a personalized contrast protocol.
PubMed 文献 · Clin Radiol · 2024-07-31

前瞻性随机将86例受试者分为两组(每组43例),A组采用100/Sn140 kVp、滤波反投影重建、碘普罗胺(370 mgI/ml)50 ml;B组采用80/Sn140 kVp、迭代重建、碘克沙醇(270 mgI/ml),并使用稀释对比剂试验团注联合个体化低浓度对比剂方案。结果显示所有病例图像质量均可满足诊断,B组有效剂量和平均碘摄入量显著降低。

要点

  • 双低剂量头颈CTA中,稀释对比剂试验团注联合个体化方案可获得诊断质量图像。
  • B组有效剂量和平均碘摄入量较A组显著降低。
  • B组颈总动脉、颈内动脉和大脑中动脉密度显著低于A组,但主动脉和基底动脉密度无显著差异。

核心结论

  • 采用稀释对比剂试验团注扫描联合个体化对比剂方案的双低剂量头颈CTA可获得诊断质量图像,并显著降低辐射剂量和对比剂剂量。

研究设计与样本

  • 前瞻性随机研究,连续纳入86例受试者,随机分为两组(每组43例):A组采用100/Sn140 kVp、滤波反投影重建、碘普罗胺(370 mgI/ml)50 ml;B组采用80/Sn140 kVp、迭代重建、碘克沙醇(270 mgI/ml),并使用稀释对比剂试验团注(27 ml稀释对比剂)联合个体化低浓度对比剂方案,血管成像时试验团注注射时长保持不变。

关键影像表现/征象

  • 所有病例图像质量均判定为可诊断。
  • 两组升主动脉和基底动脉动脉密度无显著差异。
  • B组颈总动脉、颈内动脉和大脑中动脉密度值显著低于A组。
  • B组有效剂量和平均碘摄入量显著低于A组。

诊断标准与关键数值

  • 动脉CT值超过200 Hounsfield单位被认为有显著性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To prospectively assess the value of a test bolus of diluted contrast medium (CM) combined with a personalized contrast protocol in craniocervical computed tomography angiography (cc-CTA) with low radiation and CM doses.

MATERIALS AND METHODS: Eighty-six consecutive subjects were divided into two groups at random (43 in each one): group A: 100/Sn140 kVp, filtered back-projection reconstruction, iopromide (370 mgI/ml) 50 ml; group B: 80/Sn140 kVp, iterative reconstruction, iodixanol (270 mgI/ml). In group B, the test bolus contained 27 ml of diluted CM, a personalized protocol with low-concentration CM was used for angiography, and the test bolus injection duration in angiography remained the same. Artery values over 200 Hounsfield units were considered significant.

RESULTS: Image quality for all cases was found to be diagnostic. No significant differences were found in the arterial densities of the ascending aorta or basilar artery between the groups. The values of the common carotid artery, internal carotid artery, and middle cerebral artery in group B were significantly lower. The effective dose and average iodine uptake were significantly lower in group B.

CONCLUSION: With double-low-dose cc-CTA, test bolus scanning based on diluted CM combined with a personalized contrast protocol can yield diagnostic-quality images and significantly reduce the radiation and CM doses.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Wei WF, Song LN, et al. Double low-dose computed tomography (CT) angiography of craniocervical arteries using a test bolus of diluted contrast medium and a personalized contrast protocol. Clin Radiol. 2024. PMID: 39198109. doi:10.1016/j.crad.2024.07.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。