文献速递神经骨肌MR

7 T腰骶丛神经成像:可行性与3 T MRI脊神经显示比较

7 T Lumbosacral Plexus Neurography: Feasibility and Comparison of Spinal Nerve Visualization With 3 T MRI.
PubMed 文献 · Invest Radiol · 2024-08-12

本研究为单中心、机构审查委员会批准的前瞻性研究,30名健康受试者接受采集时间匹配的7 T与3 T腰椎MR神经成像(三维双回波稳态序列)。7 T对腰神经根、背根神经节及脊神经束的显示显著优于3 T(P≤0.002),整体图像质量无差异(P=0.211),但7 T图像伪影显著增加(P<0.001)。结论支持7 T腰骶丛神经成像的可行性。

要点

  • 7 T MR神经成像对腰神经根、背根神经节及脊神经束的显示显著优于3 T(P≤0.002)。
  • 7 T与3 T整体图像质量无显著差异(P=0.211),但7 T图像伪影显著增加(P<0.001)。
  • 7 T观察者间一致性κ为0.71–0.88,3 T为0.75–0.91。

核心结论

  • 7 T MR神经成像可改善腰脊神经显示,整体图像质量与3 T相当,支持7 T腰骶丛神经成像的可行性,尽管7 T图像伪影显著增加。

研究设计与样本

  • 单中心、机构审查委员会批准的前瞻性研究,30名健康受试者,采用采集时间匹配的7 T与3 T腰椎MR神经成像(三维双回波稳态序列),由2名放射科医师采用4点Likert量表(1=差,4=优)评估。

关键影像表现/征象

  • 7 T MR神经成像对腰神经根、背根神经节及脊神经束的显示较3 T显著改善(P≤0.002)。
  • 7 T与3 T整体图像质量无差异(P=0.211)。
  • 7 T图像伪影较3 T显著增加(P<0.001)。

诊断标准与关键数值

  • 采用4点Likert量表评估神经根、背根神经节、脊神经束可见性及图像伪影与整体图像质量(1=差,4=优)。
  • 7 T观察者间一致性κ为0.71–0.88,3 T为0.75–0.91。

临床应用与阅片要点

  • 7 T MR神经成像可用于腰骶丛神经成像,腰神经根、背根神经节及脊神经束显示优于3 T。
  • 7 T整体图像质量与3 T相当,但图像伪影显著增加。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: 7 T magnetic resonance (MR) imaging can offer superior spatial resolution compared with lower field strengths. However, its use for imaging of the lumbosacral plexus has been constrained by technical challenges and therefore remained relatively unexplored. Therefore, this study investigated the feasibility of 7 T MR neurography by means of comparing the visibility of the spinal nerves and image quality to 3 T MR neurography.

MATERIALS AND METHODS: In this monocentric, institutional review board-approved, prospective study, 30 healthy subjects underwent acquisition time-matched 7 T MR neurography and 3 T MR neurography of the lumbar spine using a 3-dimensional dual-echo steady-state sequence. Visibility of the nerve root, dorsal root ganglia, and spinal nerve fascicles of L1-S1, along with image artifacts and overall image quality, were compared between the different field strengths by 2 radiologists using 4-point Likert scales (1 = poor, 4 = excellent). Comparisons between field strengths were made using the Wilcoxon signed rank test, and interobserver agreement was assessed.

RESULTS: 7 T MR neurography enabled significantly improved visualization of the lumbar nerve roots, dorsal root ganglia, and spinal nerve fascicles ( P ≤ 0.002). Compared with 3 T MR neurography, no difference in overall image quality was observed ( P = 0.211), although 7 T MR imaging exhibited significantly increased image artifacts ( P < 0.001). Interobserver agreement (κ) for qualitative measures ranged from 0.71 to 0.88 for 7 T, and from 0.75 to 0.91 for 3 T.

CONCLUSIONS: 7 T MR neurography allowed for improved visualization of lumbar spinal nerves, whereas overall image quality was comparable to 3 T MR neurography. This supports the feasibility of 7 T MR neurography of the lumbosacral plexus, even though image artifacts at 7 T were significantly increased.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Marth AA, Feuerriegel GC, Wanivenhaus F, et al. 7 T Lumbosacral Plexus Neurography: Feasibility and Comparison of Spinal Nerve Visualization With 3 T MRI. Invest Radiol. 2024. PMID: 39212499. doi:10.1097/RLI.0000000000001113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。