儿童及青少年膝与踝关节深度学习MR重建:是否已可临床使用
这项IRB批准的前瞻性研究纳入48名受试者的49例膝踝MRI,每例均含常规与深度学习序列。以常规序列为参考,深度学习序列在膝和踝的敏感度分别为90.7%和100.0%,特异度分别为99.3%和100.0%;以关节镜为参考,深度学习与常规序列敏感度均为80.0%,特异度分别为95.8%和97.9%。深度学习序列图像质量「相同或更好」,采集时间缩短一半。
要点
- 深度学习序列诊断性能与常规序列相似,膝敏感度90.7%、踝100.0%(以常规为参考)。
- 深度学习序列图像质量「相同或更好」,采集时间缩短为常规的一半。
- 骨骺状态评估一致率100.0%,踝部发现1例肌腱相关深度学习伪影(0.8%,1/125)。
核心结论
- 在儿童及青少年膝踝MRI中,深度学习序列以一半的采集时间提供与常规序列相似的诊断性能和「相同或更好」的图像质量。
研究设计与样本
- IRB批准的前瞻性研究,纳入48名受试者(10名男性,平均年龄16.4岁,范围7-29岁)的49例MRI,每例均含常规与深度学习序列,以常规序列和关节镜(如有)为参考标准。
关键影像表现/征象
- 深度学习序列在膝部未发现明确的图像改变。
- 踝部发现1例涉及肌腱的深度学习伪影(0.8%,1/125)。
- PDFS序列像素化伪影在深度学习与常规序列间差异无统计学意义(p = 0.233)。
诊断标准与关键数值
- 以常规序列为参考,膝部深度学习序列敏感度90.7%、特异度99.3%。
- 以常规序列为参考,踝部深度学习序列敏感度100.0%、特异度100.0%。
- 以关节镜为参考,深度学习序列敏感度80.0%、特异度95.8%,常规序列敏感度80.0%、特异度97.9%。
- 骨骺状态一致率100.0%。
- 膝部异常表现检出率11.7%(75/640),踝部11.5%(19/165)。
临床应用与阅片要点
- 深度学习序列图像质量除PDFS序列像素化伪影外均「相同或更好」(p < 0.032)。
- 深度学习序列采集速度快于常规序列2倍(p < 0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic performance and image quality of accelerated Turbo Spin Echo sequences using deep-learning (DL) reconstructions compared to conventional sequences in knee and ankle MRIs of children and young adults.
MATERIALS AND METHODS: IRB-approved prospective study consisting of 49 MRIs from 48 subjects (10 males, mean age 16.4 years, range 7-29 years), with each MRI consisting of both conventional and DL sequences. Sequences were evaluated blindly to determine predictive values, sensitivity, and specificity of DL sequences using conventional sequences and knee arthroscopy (if available) as references. Physeal patency and appearance were evaluated. Qualitative parameters were compared. Presence of undesired image alterations was assessed.
RESULTS: The prevalence of abnormal findings in the knees and ankles were 11.7% (75/640), and 11.5% (19/165), respectively. Using conventional sequences as reference, sensitivity and specificity of DL sequences in knees were 90.7% and 99.3%, and in ankles were 100.0% and 100.0%. Using arthroscopy as reference, sensitivity and specificity of DL sequences were 80.0% and 95.8%, and of conventional sequences were 80.0% and 97.9%. Agreement of physeal status was 100.0%. DL sequences were qualitatively "same-or-better" compared to conventional (p < 0.032), except for pixelation artifact for the PDFS sequence (p = 0.233). No discrete image alteration was identified in the knee DL sequences. In the ankle, we identified one DL artifact involving a tendon (0.8%, 1/125). DL sequences were faster than conventional sequences by a factor of 2 (p < 0.001).
CONCLUSION: In knee and ankle MRIs, DL sequences provided similar diagnostic performance and "same-or-better" image quality than conventional sequences at half the acquisition time.
引用
- Bedoya MA, Iwasaka-Neder J, Tsai A, et al. Deep learning MR reconstruction in knees and ankles in children and young adults. Is it ready for clinical use? Skeletal Radiol. 2024. PMID: 39112675. doi:10.1007/s00256-024-04769-2