文献速递骨肌MRDR

MSKI-RADS:基于MRI的肌肉骨骼感染报告与数据系统用于四肢感染诊断

MSKI-RADS: An MRI-based Musculoskeletal Infection Reporting and Data System for the Diagnosis of Extremity Infections.
PubMed 文献 · Radiology · 2024-01-01

本研究回顾性纳入208例疑似四肢感染且有参考标准的成人患者,设计并验证了基于MRI的肌肉骨骼感染报告与数据系统(MSKI-RADS)。20名来自13家机构的放射科医生阅片一致性中等(ICC 0.70),使用MSKI-RADS的总体准确率为65%±5,高于最终诊断的55%±7(P < .001)。

要点

  • MSKI-RADS将四肢感染MRI表现分为0、I–VI及NOS共8类,便于标准化报告。
  • 20名阅片者间一致性中等(ICC 0.70,95%CI 0.66–0.75)。
  • MSKI-RADS I和NOS的真阳性率最高,为88.7%(95%CI 84.6–91.7)。

核心结论

  • MSKI-RADS是有效的标准化术语系统,适用于不同肌肉骨骼 fellowship 培训水平的阅片者,用于四肢感染影像表现的报告和管理建议。

研究设计与样本

  • 回顾性横断面内部验证研究,纳入2015年6月至2019年5月间有X线片和MRI且参考标准明确的疑似四肢感染成人患者208例(男133例,女75例,平均年龄55岁±13)。

关键影像表现/征象

  • MSKI-RADS分类:0为影像不完整;I为无感染;II为浅表软组织感染;III为深部软组织感染;IV为可能骨髓炎;V为高度提示骨髓炎和/或化脓性关节炎;VI为已知骨髓炎;NOS为非特异性骨病变。

诊断标准与关键数值

  • 各类别病例数:I类20例,II类34例,III类35例,IV类30例,V类35例,VI类18例,NOS类36例。
  • MSKI-RADS I和NOS的真阳性率最高,为88.7%(95%CI 84.6–91.7)。
  • MSKI-RADS V的真阳性率为73%(95%CI 63–80)。
  • 20名阅片者间一致性中等,ICC为0.70(95%CI 0.66–0.75)。
  • 阅片者经验与总体准确率无相关性证据(P = .94)。

临床应用与阅片要点

  • 使用MSKI-RADS的总体阅片准确率为65%±5,高于最终阅片诊断的55%±7(P < .001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Current terms used to describe the MRI findings for musculoskeletal infections are nonspecific and inconsistent. Purpose To develop and validate an MRI-based musculoskeletal infection classification and scoring system. Materials and Methods In this retrospective cross-sectional internal validation study, a Musculoskeletal Infection Reporting and Data System (MSKI-RADS) was designed. Adult patients with radiographs and MRI scans of suspected extremity infections with a known reference standard obtained between June 2015 and May 2019 were included. The scoring categories were as follows: 0, incomplete imaging; I, negative for infection; II, superficial soft-tissue infection; III, deeper soft-tissue infection; IV, possible osteomyelitis (OM); V, highly suggestive of OM and/or septic arthritis; VI, known OM; and NOS (not otherwise specified), nonspecific bone lesions. Interreader agreement for 20 radiologists from 13 institutions (intraclass correlation coefficient [ICC]) and true-positive rates of MSKI-RADS were calculated and the accuracy of final diagnoses rendered by the readers was compared using generalized estimating equations for clustered data. Results Among paired radiographs and MRI scans from 208 patients (133 male, 75 female; mean age, 55 years ± 13 [SD]), 20 were category I; 34, II; 35, III; 30, IV; 35, V; 18, VI; and 36, NOS. Moderate interreader agreement was observed among the 20 readers (ICC, 0.70; 95% CI: 0.66, 0.75). There was no evidence of correlation between reader experience and overall accuracy (P = .94). The highest true-positive rate was for MSKI-RADS I and NOS at 88.7% (95% CI: 84.6, 91.7). The true-positive rate was 73% (95% CI: 63, 80) for MSKI-RADS V. Overall reader accuracy using MSKI-RADS across all patients was 65% ± 5, higher than final reader diagnoses at 55% ± 7 (P < .001). Conclusion MSKI-RADS is a valid system for standardized terminology and recommended management of imaging findings of peripheral extremity infections across various musculoskeletal-fellowship-trained reader experience levels. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Schweitzer in this issue.

来源:Radiology,查看原文。版权归原作者所有。