PubMed 文献 · Radiology · 2024-01-01

这项在荷兰三个筛查点进行的随机对照试验纳入2499名女性,比较弧形压迫板与伪装标准压迫板的疼痛与图像质量;弧形板组疼痛评分较对照组额外降低0.19分(95%CI:0.09,0.28;P<.001),但观察者未偏好弧形板图像,图像质量下降。

要点

  • 弧形压迫板使乳腺压迫疼痛评分较标准板额外降低0.19分(95%CI:0.09,0.28;P<.001)。
  • 图像质量方面,观察者对弧形板图像无偏好或偏好标准板图像。
  • 弧形板图像的主要问题为对比度下降和结构可见性降低。

核心结论

  • 使用弧形压迫板可使乳腺X线摄影压迫时的疼痛轻度降低,但图像质量下降。

研究设计与样本

  • 随机对照试验,2021年10月至2022年2月在荷兰三个筛查点进行,2499名女性参与者(平均年龄61.6岁±7.1[SD])随机分为弧形压迫板组1250人和伪装标准压迫板组1249人;在标准筛查检查中额外采集一张弧形或伪装压迫板图像;两名放射技师和两名放射科医生进行非盲配对比较,使用标准图像质量标准(技师评估1246对图像、12项标准;放射科医生评估320对图像、6项标准)。

关键影像表现/征象

  • 弧形压迫板组疼痛评分较伪装标准压迫板组额外降低0.19分(95%CI:0.09,0.28;P<.001)。
  • 图像质量方面,观察者无偏好或偏好标准压迫板图像。
  • 弧形压迫板图像的主要关注点为对比度下降(Bonferroni校正P值范围:P<.001至P>.99)和结构可见性降低。

诊断标准与关键数值

  • 疼痛采用数字评分量表(范围0-10)测量,参与者在标准压迫板和测试压迫板压迫后各提供一个疼痛评分。
  • 图像质量由两名放射技师使用12项标准评估1246对图像、两名放射科医生使用6项标准评估320对图像进行非盲配对比较。
  • 采用单样本Wilcoxon符号秩检验判断是否存在对任一压迫板的显著偏好。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background A curve-shaped compression paddle could reduce the pain experienced by some women at breast cancer screening. Purpose To compare curved and standard compression systems in terms of pain experience and image quality in mammography screening. Materials and Methods In this randomized controlled trial conducted between October 2021 and February 2022, participants screened at three screening sites in the Netherlands were randomized to either a curved-paddle or sham-paddle group. The sham paddle was a standard paddle that was presented as a new paddle. At a standard screening examination, one additional image was acquired with a curved or sham paddle. Pain was measured on a numerical rating scale (range, 0-10). Participants provided a pain score after compression with the standard and test paddles, resulting in two scores per participant. Differences in pain scores were compared between groups using analysis of covariance, adjusting for pain score after standard-paddle compression. Two radiographers and two radiologists performed unblinded paired comparisons of curved-paddle vs standard-paddle images, using standard image quality criteria (radiographers evaluated 1246 image pairs using 12 criteria; radiologists evaluated 320 image pairs using six criteria). The one-sample Wilcoxon signed-rank test was used to determine if there was a significant preference for either paddle. Results In total, 2499 female participants (mean age, 61.6 years ± 7.1 [SD]) were studied; 1250 in the curved-paddle group and 1249 in the sham-paddle group. The mean pain score decreased by an additional 0.19 points in the curved-paddle group compared with the sham-paddle group (95% CI: 0.09, 0.28; P < .001). In terms of image quality, the observers showed no preference or a preference for the standard paddle. Decreased image contrast (range Bonferroni-corrected P values: P < .001 to P > .99) and visibility of structures were the main concerns for curved-paddle images. Conclusion The use of the curved paddle resulted in a minimal pain reduction during mammography breast compression but image quality was reduced. © RSNA, 2024 Supplemental material is available for this article.