应用应变弹性成像与计算机辅助诊断系统下调超声乳腺影像报告和数据系统分类:一项多中心前瞻性研究

Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study.
PubMed 文献 · Br J Radiol · 2024-01-01

这项多中心前瞻性研究纳入2020至2022年间1049个BI-RADS 3及4a-c类乳腺肿块(良性691个、恶性358个),评估在常规超声基础上加用应变弹性成像应变比(SR)和基于深度学习的计算机辅助诊断(CAD)系统重新分类BI-RADS 4a类肿块的效果。结果显示,重新分类后不必要的活检从48.6%(336/691)降至25.62%(177/691),减少50.14%(177 vs 355),新BI-RADS 3组仅遗漏1.72%(9/523)的恶性肿瘤。作者认为加用SR和CAD可能将BI-RADS 4a类下调为3类,使50.14%的肿块避免活检,未检出恶性肿瘤率为可接受的1.72%。

要点

  • SR阈值<2.90且CAD二分法判为可能良性时,可将BI-RADS 4a类肿块重新分类为3类。
  • 重新分类后不必要的活检减少50.14%(177 vs 355),新BI-RADS 3组遗漏恶性肿瘤1.72%(9/523)。
  • 常规超声评估后48.6%(336/691)的良性肿块接受了不必要的活检。

核心结论

  • 在临床实践中加用SR和CAD可能对BI-RADS 4a类下调为3类表现出最佳性能,50.14%的肿块可获益,未检出恶性肿瘤率1.72%为可接受值。

研究设计与样本

  • 前瞻性多中心研究,纳入1049个BI-RADS 3及4a-c类乳腺肿块(良性691个、恶性358个),2020至2022年;所有患者接受SR和CAD检查,以组织病理学为参考标准。

诊断标准与关键数值

  • BI-RADS 4a类重新分类为3类的条件为SR截断值<2.90且CAD二分法判为可能良性;常规超声后不必要的活检率为48.6%(336/691),重新分类后为25.62%(177/691),减少50.14%(177 vs 355);新BI-RADS 3组遗漏恶性肿瘤1.72%(9/523)。

临床应用与阅片要点

  • 作者认为将SR和CAD加入临床实践可能对BI-RADS 4a类重新分类为3类表现出最佳性能,并使50.14%的肿块获益。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether adding elastography strain ratio (SR) and a deep learning based computer-aided diagnosis (CAD) system to breast ultrasound (US) can help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3 and 4a-c categories and avoid unnecessary biopsies.

METHODS: This prospective, multicentre study included 1049 masses (691 benign, 358 malignant) with assigned BI-RADS 3 and 4a-c between 2020 and 2022. CAD results was dichotomized possibly malignant vs. benign. All patients underwent SR and CAD examinations and histopathological findings were the standard of reference. Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after reclassified (new BI-RADS 3) with SR and CAD were the outcome measures.

RESULTS: Following the routine conventional breast US assessment, 48.6% (336 of 691 masses) underwent unnecessary biopsies. After reclassifying BI-RADS 4a masses (SR cut-off <2.90, CAD dichotomized possibly benign), 25.62% (177 of 691 masses) underwent an unnecessary biopsies corresponding to a 50.14% (177 vs. 355) reduction of unnecessary biopsies. After reclassification, only 1.72% (9 of 523 masses) malignancies were missed in the new BI-RADS 3 group.

CONCLUSION: Adding SR and CAD to clinical practice may show an optimal performance in reclassifying BI-RADS 4a to 3 categories, and 50.14% masses would be benefit by keeping the rate of undetected malignancies with an acceptable value of 1.72%.

ADVANCES IN KNOWLEDGE: Leveraging the potential of SR in conjunction with CAD holds immense promise in substantially reducing the biopsy frequency associated with BI-RADS 3 and 4A lesions, thereby conferring substantial advantages upon patients encompassed within this cohort.

来源:Br J Radiol,查看原文。版权归原作者所有。