超声引导下真空辅助乳腺活检在影像-病理不一致管理中的作用:一项回顾性单中心研究
超声引导下真空辅助活检发现了粗针活检漏诊的近50%的癌症,避免了外科活检,验证其为影像-病理不一致中有效的微创方法。
要点
- 超声引导下真空辅助活检在影像-病理不一致中升级为恶性率47.2%(17/36)。
- BI-RADS 5类病灶升级率100%(2/2)、4C类67%(12/18)、4B类19%(3/16),P=0.006。
- 肿块形态(P=0.008)和BI-RADS分类(P=0.006)与升级为恶性相关。
核心结论
- 超声引导下真空辅助活检发现了粗针活检漏诊的近50%的癌症,避免了外科活检,验证其为影像-病理不一致中有效的微创方法。
关键影像表现/征象
- 二线超声引导下真空辅助活检检出B2类10个、B3类9个、B5类17个病灶。
- 升级为恶性的病灶中包括8例浸润性非特殊型癌、7例导管原位癌、1例浸润性小叶癌和1例血管肉瘤。
- 恶性病灶在BI-RADS分类中的分布为:BI-RADS 5类2/2(100%)、4C类12/18(67%)、4B类3/16(19%)(P=0.006)。
诊断标准与关键数值
- 超声引导下真空辅助活检升级为恶性率47.2%(17/36)。
- 超声引导下真空辅助活检假阴性率15.8%(3/19),最终升级为恶性率55%(20/36)。
- 超声引导下真空辅助活检敏感度85%、特异度100%、阳性预测值100%、阴性预测值84%、准确率92%。
- 单因素分析显示肿块形态(P=0.008)和BI-RADS分类(P=0.006)与升级为恶性相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the efficacy of US-guided vacuum-assisted biopsy (US-VAB) in radiologic-pathologic (rad-path) discordance in women with suspicious breast lesions.
METHODS: Two thousand three hundred and sixty patients with 2385 BI-RADS category 4 and 5 lesions underwent percutaneous US-guided CNB. Thirty-six lesions were classified as discordant benign and underwent second-line US-VAB. A 14-gauge needle was utilized for CNB and 10-gauge for US-VAB. Final pathology was the reference standard for women who underwent surgery, imaging follow-up in other cases. Rates of malignancy for US-VAB and subsequent surgery were evaluated. Lesions with upgrade and no upgrade to second-line VAB were compared in terms of patient's age, lesion type and characteristics, size and BI-RADS category. Positive predictive value (PPV), negative predictive value (NPV) for BI-RADS categories and diagnostic performance for second-line US-VAB were calculated. p value < 0.05 was considered statistically significant (t-test, Mann-Whitney, χ2).
RESULTS: US-VAB identified 10 B2, 9 B3 and 17 B5 lesions with upgrade to malignancy of 47.2% (17/36). There were 8 invasive no special type, 7 ductal in situ, 1 invasive lobular carcinoma and 1 angiosarcoma, and their distribution among BI-RADS categories was: 2/2 in BI-RADS 5 (100%), 12/18 in BI-RADS 4C (67%) and 3/16 in BI-RADS 4B lesions (19%) (p = 0.006). Of the remaining 19 lesions, 6 underwent surgery and 2 were upgraded to ductal carcinoma in situ; 13 underwent radiological follow-up and one resulted malignant. False-negative rate for US-VAB was 15.8% (3/19) with final upgrade to malignancy of 55% (20/36). The univariate analysis revealed mass shape (p = 0.008) and BI-RADS categories (p = 0.006) to be associated with upgrade to malignancy. Sensitivity, specificity, PPV, NPV and accuracy for US-VAB were 85, 100, 100, 84 and 92%, respectively.
CONCLUSIONS: US-VAB identified almost 50% of cancers missed by CNB, avoiding surgical biopsies and validating as an effective mini-invasive approach in rad-path discordance.
引用
- Vatteroni G, Pinna G, Trimboli RM, et al. Role of ultrasound-guided vacuum-assisted breast biopsy in the management of radiologic-pathologic discordance: a retrospective single-centre study. Radiol Med. 2024. PMID: 39102107. doi:10.1007/s11547-024-01864-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。