挪威乳腺癌筛查项目中筛查乳腺X线摄影的初始解读评分与癌症检出
该研究分析挪威乳腺癌筛查项目2012-2020年间1,689,731次筛查检查(3,379,462侧乳腺),由两名放射科医师独立给出1-5分评分。结果显示,召回率、筛查检出癌症率和阳性预测值1随两名医师评分总和增加而升高(趋势p<0.001),高分侧乳腺中浸润性癌、组织学3级和淋巴结阳性肿瘤比例更高,但相当数量召回和筛查检出癌症的评分较低。
要点
- 双侧乳腺独立评分,每侧由两名放射科医师独立评1-5分,1分为阴性/良性,≥2分为阳性。
- 召回率、筛查检出癌症率和阳性预测值1随两名医师评分总和增加而升高(趋势p<0.001)。
- 高分侧乳腺的浸润性癌、组织学3级和淋巴结阳性肿瘤比例更高(p<0.001)。
核心结论
- 高解读评分对应更高的召回率、筛查检出癌症率和更不利的病理肿瘤特征,但相当数量召回和筛查检出癌症的评分较低。
研究设计与样本
- 分析挪威乳腺癌筛查项目2012-2020年间1,689,731次筛查检查(3,379,462侧乳腺),每侧乳腺由两名放射科医师独立评1-5分,按乳腺侧和检查侧进行描述性分析。
关键影像表现/征象
- 低评分召回和筛查检出癌症中肿块比例较高,高评分中毛刺状肿块比例较高(p<0.001)。
- 高分侧乳腺的浸润性癌、组织学3级和淋巴结阳性肿瘤比例高于低分侧乳腺(p<0.001)。
诊断标准与关键数值
- 评分系统:1分为阴性/良性,≥2分为阳性。
- 3.9%(132,570/3,379,462)的乳腺侧被一名或两名医师评为≥2分,其中84.8%(112,440/132,570)最高评分为2分。
- 总召回率1.6%(53,735/3,379,462),其中69.3%(37,220/53,735)最高评分为2分。
- 筛查检出癌症0.3%(9,733/3,379,462),其中34.6%(3,369/9,733)最高评分为3分。
- 召回率、筛查检出癌症率和阳性预测值1随两名医师评分总和增加而升高(趋势p<0.001)。
临床应用与阅片要点
- 阅片时注意低评分也可能对应召回和筛查检出癌症,报告需结合影像特征综合判断。
- 毛刺状肿块更多见于高评分侧乳腺,低评分侧乳腺中肿块比例较高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the association between radiologists' interpretation scores, early performance measures and cumulative reading volume in mammographic screening.
METHOD: We analyzed 1,689,731 screening examinations (3,379,462 breasts) from BreastScreen Norway 2012-2020, all breasts scored 1-5 by two independent radiologists. Score 1 was considered negative/benign and score ≥2 positive in this scoring system. We performed descriptive analyses of recall, screen-detected cancer, positive predictive value (PPV) 1, mammographic features and histopathological characteristics by breast-based interpretation scores, and cumulative reading volume by examination-based interpretation scores.
RESULTS: Counting breasts and not women, 3.9 % (132,570/3,379,462) had a score of ≥2 by one or both radiologists. Of these, 84.8 % (112,440/132,570) were given a maximum score 2. Total recall rate was 1.6 % (53,735/3,379,462), 69.3 % (37,220/53,735) given maximum score 2. Among the 0.3 % (9733/3,379,462) diagnosed with screen-detected cancer, 34.6 % (3369/9733) had maximum score 3. The percentages of recall, screen-detected cancer and PPV-1 increased by increasing the sum of scores assigned by two radiologists (p < 0.001 for trend). Higher proportions of masses were observed among recalls and screen-detected cancers with low scores, and higher proportions of spiculated masses were observed for high scores (p < 0.001). Proportions of invasive carcinoma, histological grade 3 and lymph node positive tumors were higher for high versus low scores (p < 0.001). The proportion of examinations scored 1 increased by cumulative reading volume.
CONCLUSIONS: We observed higher rates of recall and screen-detected cancer and less favorable histopathological tumor characteristics for high versus low interpretation scores. However, a considerable number of recalls and screen-detected cancers had low interpretation scores.
引用
- Hovda T, Sagstad S, Moshina N, et al. Initial interpretation scores of screening mammograms and cancer detection in BreastScreen Norway. Eur J Radiol. 2024. PMID: 39159548. doi:10.1016/j.ejrad.2024.111662
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。