卵巢黏液性肿瘤良性与交界性及恶性鉴别诊断中的显著磁共振成像表现
回顾性分析2011年1月至2021年12月50例患者54个卵巢黏液性肿瘤的术前MRI,比较良性(33个)、交界性(13个)与恶性(8个)组的影像特征。恶性组肿瘤更大、分房数更多、壁结节数量及出现频率更高、ADC值更低,且腹水更显著;良性组分隔厚度更低(最佳截断值2.45 mm,敏感度79%、特异度75%、AUC 0.861);交界性组壁结节T2加权信号强度比高于恶性组(截断值3.9,敏感度85%、特异度83%、AUC 0.943)。
要点
- 壁结节T2加权信号强度比以3.9为截断值有助于交界性与恶性黏液性肿瘤的鉴别。
- 分隔厚度以2.45 mm为最佳截断值有助于将良性组与交界性及恶性组区分。
- 恶性组肿瘤更大、分房数更多、壁结节数量及出现频率更高、ADC值更低且腹水更显著。
核心结论
- 壁结节T2加权信号强度比以3.9为截断值有利于鉴别诊断;认识肿瘤大小、分隔厚度、分房数、壁结节数量及T2加权信号强度比、ADC值和腹水等显著MRI表现,可在术前预测黏液性肿瘤的组织学亚组以辅助治疗规划。
研究设计与样本
- 回顾性研究,纳入2011年1月至2021年12月50例患者共54个卵巢黏液性肿瘤的术前MRI,依据组织病理结果分为良性(33个)、交界性(13个)和恶性(8个)组,采用Kruskal Wallis检验、Pearson卡方检验和受试者工作特征分析。
关键影像表现/征象
- 恶性组肿瘤大小、分房数、壁结节数量及出现频率均高于良性及交界性组,ADC值低于良性及交界性组(p<0.05)。
- 良性组分隔厚度低于交界性及恶性组,最佳截断值2.45 mm(p<0.05)。
- 交界性组壁结节T2加权信号强度比高于恶性组,截断值3.9(p<0.05)。
- 腹水在恶性组中亦具有显著性(p<0.05)。
诊断标准与关键数值
- 分隔厚度以2.45 mm为最佳截断值区分良性组与交界性及恶性组:敏感度79%、特异度75%、AUC 0.861(p<0.05)。
- 壁结节T2加权信号强度比以3.9为截断值区分交界性与恶性组:敏感度85%、特异度83%、AUC 0.943(p<0.05)。
临床应用与阅片要点
- 作者认为,认识肿瘤大小、分隔厚度、分房数、壁结节数量及T2加权信号强度比、ADC值和腹水等显著MRI表现,可在术前预测黏液性肿瘤的组织学亚组以辅助治疗规划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: In mucinous ovarian tumors, preoperative prediction of histological subgroup is important for treatment approach. Therefore, we aimed to determine salient magnetic resonance imaging (MRI) findings and estimate optimal cut off values for quantitative features in differential diagnosis of benign, borderline and malignant mucinous ovarian tumors.
METHODS: Between January 2011 and December 2021, preoperative MRI scans of 50 patients with mucinous ovarian tumors (n = 54) were evaluated retrospectively. MRI findings [size, signal intensity, contrast pattern, features of loculation, wall, septa and mural nodule (MN), diffusion restriction] were investigated. There were benign, borderline, and malignant groups based on histopathological results. The relationship between radiological and histopathological results was analyzed by performing Kruskal Wallis test, Pearson's chi-squared test, receiver operating characteristic analysis.
RESULTS: In our study, there were 54 mucinous ovarian tumors in 50 patients. Of 54, 33 were benign, 13 borderline and eight malignant tumors. In comparison of three groups, tumor size, number of loculation, number and frequency of MN were higher and apparent diffusion coefficient (ADC) value were lower in malignant group (p < 0.05). Septa thickness was lower with optimal cut off value of 2.45 mm in benign group compared to borderline and malignant groups [sensitivity: 79%, specificity: 75%, AUC (Area under the curve): 0.861] (p < 0.05). T2-weighted (T2-w) signal intensity ratio (SIR) of MN was higher in borderline compared to malignant group, with a cut-off value of 3.9 (sensitivity: 85%, specificity: 83%, AUC: 0.943) (p < 0.05). Ascites was also significant in malignant group (p < 0.05).
CONCLUSION: T2-w SIR of MN with a cut off value of 3.9 is beneficial for differential diagnosis. By awareness of some salient MRI findings (size, septa thickness, number of loculation, number and T2-w SIR of MN, ADC value and ascites), preoperative prediction of histological subgroup of mucinous tumors for appropriate treatment planning is possible.
引用
- Ozyilmaz S, Kulali F, Topal CS, et al. Salient magnetic resonance imaging findings in the differential diagnosis of benign, borderline and malignant ovarian mucinous tumors. Abdom Radiol (NY). 2024. PMID: 39187694. doi:10.1007/s00261-024-04545-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。