超声评估脐带与胎盘血管血流用于预防脐带意外死产的初步研究

A Pilot Study of Ultrasound Assessment of Umbilical Cord and Placental Vascular Flow for Cord Accident Stillbirth Prevention.
PubMed 文献 · J Ultrasound Med · 2024-08-07

前瞻性初步研究纳入53例孕36周、胎盘前壁的低危孕妇,由不同检查者行两次超声,评估三个脐带部位及母胎胎盘小动脉血流。自由环、胎盘插入处及胎儿胎盘小动脉获取成功率高(90.6%-99.1%),自由环收缩/舒张及搏动指数观察者间信度0.38-0.44,胎儿插入处及胎盘小动脉信度均差。作者认为自由环、胎盘插入处及胎盘小动脉血流评估可行,信度因测量类型和部位而异,需进一步研究非前壁胎盘及临床相关性。

要点

  • 孕36周低危前壁胎盘孕妇中,自由环、胎盘插入处及胎儿胎盘小动脉血流测量获取成功率90.6%-99.1%。
  • 自由环收缩/舒张及搏动指数观察者间信度仅0.38-0.44,胎儿插入处及胎盘小动脉信度均差。
  • 各参数在不同脐带部位间变异范围4.3%-21.7%,报告时需注明测量部位。

核心结论

  • 在本队列中,自由环、胎盘插入处及胎盘小动脉血流评估可行,但检查者间信度因测量类型和脐带部位而异;尚需未来研究确定非前壁胎盘者的可行性与信度并评估临床相关性。

研究设计与样本

  • 前瞻性初步研究,纳入53例孕36周、胎盘前壁的低危孕妇,排除有产前检查或39周前分娩指征者;每例由不同检查者行两次超声,包括三个脐带部位(胎儿端、自由环、胎盘端)的动静脉流速测量及母体与胎儿胎盘小动脉测量;以Pearson相关系数量化观察者间信度,并以标准临床参数作为解读基准。

诊断标准与关键数值

  • 自由环、胎盘脐带插入处及胎儿胎盘小动脉测量的获取成功率范围为90.6%-99.1%。
  • 胎儿脐带插入处及母体螺旋小动脉测量的获取成功率范围为47.2%-87.7%。
  • 自由环收缩/舒张及搏动指数的观察者间信度估计范围为0.38-0.44。
  • 各参数在不同脐带部位间的变异范围为4.3%-21.7%。
  • 实验参数的观察者间信度因测量部位而异,在胎儿插入处及胎盘小动脉中均差。

局限性

  • 原文结论指出尚需未来研究确定非前壁胎盘者的可行性与信度并评估临床相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Our objective was to determine the feasibility and interobserver reliability of umbilical cord and placental arteriolar flow assessment in low-risk pregnancies near term.

METHODS: This was a prospective pilot study in low-risk pregnancies at 36 weeks with anterior placentas. We excluded any with an indication for antenatal testing or delivery before 39 weeks. Each participant underwent two ultrasounds by different examiners, which included arterial and venous velocimetry at three cord sites (fetal, free loop, and placental) in addition to maternal and fetal placental arterioles. The interobserver reliability was quantified using the Pearson correlation coefficient with that of standard clinical parameters serving as a benchmark for interpretation.

RESULTS: Among 53 participants scanned at 356/7-371/7 weeks, the mean examination duration was 20.5 ± 4.2 minutes. Ascertainment success was high for measures at the free loop, placental cord insertion, and fetal placental arterioles (range 90.6%-99.1%) and was lower at the fetal cord insertion and maternal spiral arterioles (range 47.2%-87.7%). Interobserver reliability estimates for free-loop systolic/diastolic and pulsatility index ranged from 0.38 to 0.44. Interobserver reliability for experimental parameters varied by measurement site, and all were poor at the fetal insertion and in placental arterioles. Parameters had significant variation across cord sites (range 4.3%-21.7%).

CONCLUSION: In our cohort, flow assessments of the free loop, placental insertion, and placental arterioles are feasible, but interrater reliability varies by measurement type and cord site. Future studies are needed to establish feasibility and reliability in nonanterior placentation and to assess clinical relevance.