文献速递妇产影像US

超声估测胎儿体重:三次测量平均值是否比单次测量更准确?

Ultrasonic Estimation of Fetal Weight: Are Averaged Triplicate Measurements More Accurate Than Single Measurements?
PubMed 文献 · J Ultrasound Med · 2024-08-06

这项前瞻性单中心研究纳入100名预计72小时内分娩的足月产妇,按ISUOG指南用Hadlock公式估测胎儿体重,比较三次不同图像测量平均值与首次单次测量的准确性。三次测量平均值较单次测量有小而显著的改善(平均改善34±105 g,P=.002),与出生体重的偏差中位数单次测量198 g vs 平均值148 g(P=.005),第75百分位处差异更明显(348 g vs 282 g)。

要点

  • 三次测量平均值较单次测量使EFW与出生体重偏差中位数从198 g降至148 g(P=.005)。
  • 第75百分位处偏差单次测量348 g vs 三次测量平均值282 g,差异更明显。
  • EFW平均改善34±105 g(P=.002),幅度小但具统计学显著性。

核心结论

  • 使用三次测量替代单次测量进行EFW可带来小幅但具统计学显著性的准确性提升,尤其在怀疑生长异常时值得考虑。

研究设计与样本

  • 前瞻性单中心研究,纳入100名预计72小时内分娩的足月产妇,按ISUOG指南检查,采用Hadlock公式计算EFW,每个参数从三幅不同图像各测一次取平均值,并与首次单次测量计算的EFW比较。

诊断标准与关键数值

  • EFW采用Hadlock公式计算,测量操作遵循ISUOG指南;以出生体重为参照,单次测量偏差中位数198 g vs 三次测量平均值148 g(P=.005),第75百分位偏差单次测量348 g vs 平均值282 g,平均改善34±105 g(P=.002)。

临床应用与阅片要点

  • 作者认为在EFW评估中应考虑使用三次测量平均值,尤其在怀疑生长异常的病例中。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess whether, and to what extent, performing triplicate measurements can improve accuracy of estimation of fetal weight (EFW) compared to single measurements.

METHODS: This was a prospective study conducted at a single medical center. A total of 100 term parturients with an anticipated delivery within 72 hours were recruited for EFW measurements. All examinations were done with adherence to the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guidelines. EFW was calculated using the Hadlock formula. Triplicate measurements from three different images were obtained for each parameter and the averaged values were used for clinical purposes. EFW calculated using average measurements was compared to EFW calculated using the first measurements.

RESULTS: There was a small but significant improvement in EFW when using averaged measurements compared to single measurements (mean improvement 34 ± 105 g, P = .002). Deviance from birthweight in single measurements was significantly higher compared to averaged measurements (median deviance 198 versus 148 g, respectively, P = .005). This difference was more pronounced when assessing the 75th centile (348 versus 282 g, respectively).

CONCLUSIONS: Using triplicate measurements instead of single measurements when performing EFW confers a small, but statistically significant, improvement to EFW accuracy. Using triplicate measurements for assessing EFW should be thus considered, especially in cases suspected of growth disorders.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Sheiman V, Frenkel A, Glick N, et al. Ultrasonic Estimation of Fetal Weight: Are Averaged Triplicate Measurements More Accurate Than Single Measurements? J Ultrasound Med. 2024. PMID: 39105327. doi:10.1002/jum.16545

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。