文献速递泌尿生殖腹部CT

双能CT多参数图像对影像组学预测膀胱尿路上皮癌病理分级的影响

Impact of multi-parameter images obtained from dual-energy CT on radiomics to predict pathological grading of bladder urothelial carcinoma.
PubMed 文献 · Abdom Radiol (NY) · 2024-08-12

本研究回顾性分析112例膀胱尿路上皮癌患者的术前双能CT,基于碘图、水图及40~140 keV虚拟单能图像共13组图像集提取影像组学特征,用随机森林构建预测病理分级的模型。测试集中各模型AUC为0.841~0.895,碘图和水图模型AUC分别为0.873和0.852,图像类型变化未影响模型预测性能。

要点

  • 双能CT碘图、水图及40~140 keV虚拟单能图像均可构建膀胱尿路上皮癌病理分级预测模型。
  • 测试集中13个模型AUC为0.841~0.895,碘图模型AUC为0.873、水图模型AUC为0.852。
  • 各图像集所选最佳影像组学特征虽不同,但预测性能无统计学显著差异。

核心结论

  • 尽管双能CT多参数图像所选影像组学特征存在差异,但影像组学模型预测膀胱尿路上皮癌病理分级的性能不受模型训练所用图像类型变化的影响。

研究设计与样本

  • 回顾性分析112例确诊膀胱尿路上皮癌患者的术前双能CT检查,其中高级别尿路上皮癌76例、低级别尿路上皮癌36例。

诊断标准与关键数值

  • 测试集中40~140 keV(间隔10 keV)图像集构建模型的AUC分别为0.895、0.874、0.855、0.889、0.841、0.868、0.852、0.847、0.889、0.887和0.863;碘图模型AUC为0.873,水图模型AUC为0.852。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effect of radiomics models obtained from dual-energy CT (DECT) material decomposition images and virtual monoenergetic images (VMIs) in predicting the pathological grading of bladder urothelial carcinoma (BUC).

MATERIALS AND METHODS: A retrospective analysis of preoperative DECT examination was conducted on 112 patients diagnosed with BUC. This cohort included 76 cases of high-grade urothelial carcinoma and 36 cases of low-grade urothelial carcinoma. DECT can provide material decomposition images of venous phase Iodine maps and Water maps based on the differences in attenuation of substances, as well as VMIs at 40 to 140 keV (interval 10 keV). A total of 13 image sets were obtained, and radiomics features were extracted and analyzed from each set to achieve preoperative prediction of BUC. The best features related to BUC were identified by recursive feature elimination (RFE), the Minimum Redundancy Maximum Relevance (mRMR), and the Least Absolute Shrinkage and Selection Operator (LASSO) in order. A five-fold cross-validation method was used to divide the samples into training and testing sets, and models for pathological prediction of BUC grading were constructed by a random forest (RF) classifier. Receiver operating curves (ROC) were plotted to evaluate the performance of 13 models obtained from each image set.

RESULTS: Despite the notable differences in the best radiomics features chosen from each image set, all the features selected from 40 to 100 keV VMIs included the Dependence Variance of the GLDM feature set. There were no statistically significant differences in the area under the curve (AUC) between the training set and the testing set for all 13 models. In the testing set, the AUCs of the models established through 40 keV to 140 keV (interval of 10 keV) image sets were 0.895, 0.874, 0.855, 0.889, 0.841, 0.868, 0.852, 0.847, 0.889, 0.887 and 0.863 respectively. The AUCs for the models established using the Iodine maps and Water maps image sets were 0.873 and 0.852, respectively.

CONCLUSION: Despite the differences in the selected radiomic features from DECT multi-parameter images, the performance of radiomics models in predicting the pathological grading of BUC was not affected by the variations in the types of images used for model training.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wei W, Wang S, Hu M, et al. Impact of multi-parameter images obtained from dual-energy CT on radiomics to predict pathological grading of bladder urothelial carcinoma. Abdom Radiol (NY). 2024. PMID: 39134869. doi:10.1007/s00261-024-04516-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。