文献速递泌尿生殖妇产影像PETMR

采用MR主动触发与贝叶斯惩罚似然重建的时间同步2-脱氧-2-[18F]氟-D-葡萄糖PET/MRI:对子宫内膜癌局部区域扩散的诊断价值

Time-synchronized 2-deoxy-2-[18F]fluoro-D-glucose PET/MRI with MR-active trigger and Bayesian penalized likelihood reconstruction: Diagnostic utility for locoregional extension of endometrial cancer.
PubMed 文献 · Eur J Radiol · 2024-08-10

回顾性纳入55例子宫内膜癌患者,评估以MR主动触发确定PET发射时间并结合贝叶斯惩罚似然重建的时间同步PET/MRI。时间同步PET/MRI的T分期与病理T分期一致性最高,对新阅片者诊断深肌层浸润的效能和置信度显著高于重叠PET/MRI,序贯PET/MRI膀胱尺寸差异显著大于重叠和时间同步PET/MRI。

要点

  • 时间同步PET/MRI的T分期与病理T分期一致性最高。
  • 新阅片者中时间同步PET/MRI诊断深肌层浸润的效能显著高于重叠PET/MRI。
  • 序贯PET/MRI的膀胱尺寸差异显著大于重叠和时间同步PET/MRI。

核心结论

  • 时间同步PET/MRI在评估子宫内膜癌局部区域扩散方面优于常规PET/MRI。

研究设计与样本

  • 回顾性研究,纳入55例子宫内膜癌患者,行盆腔2-脱氧-2-[18F]氟-D-葡萄糖PET/MRI,由两名阅片者评估。

关键影像表现/征象

  • 时间同步PET/MRI通过各MR序列的MR主动触发确定BPL重建的PET发射时间。
  • 序贯PET/MRI图像膀胱尺寸差异显著大于重叠和时间同步PET/MRI(p <0.001)。

诊断标准与关键数值

  • 两名阅片者中时间同步PET/MRI的T分类与病理T分类一致性最高。
  • 新阅片者中时间同步PET/MRI诊断深肌层浸润的效能显著高于重叠PET/MRI(p = 0.033)。
  • 新阅片者中时间同步PET/MRI的置信度评分显著高于重叠PET/MRI(p = 0.038)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Minimal misregistration of fused PET and MRI images can be achieved with simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI). However, the acquisition of multiple MRI sequences during a single PET emission scan may impair fusion precision of each sequence. This study evaluated the diagnostic utility of time-synchronized PET/MRI using an MR active trigger and a Bayesian penalized likelihood reconstruction algorithm (BPL) to assess the locoregional extension of endometrial cancer.

METHODS: Fifty-five patients with endometrial cancer who underwent pelvic 2-deoxy-2-[18F]fluoro-D-glucose PET/MRI were retrospectively evaluated. The PET emission time for the BPL reconstruction was determined by the MR active trigger of each MR sequence. The concordance rates of image interpretation with pathological T-staging, diagnostic performance for deep myometrial invasion (MI), and diagnostic confidence levels were evaluated by two readers and compared between time-synchronized, overlapping (conventional and simultaneous, but not time-synchronized), and sequential (not simultaneous) PET/MRI and MRI with diffusion-weighted imaging. Misregistration of the PET/MRI-fused images was determined by evaluating the differences in bladder dimensions.

RESULTS: The T classification by time-synchronized PET/MRI was the most concordant with the pathological T classification for the two readers. Time-synchronized PET/MRI had a significantly higher diagnostic performance for deep MI and higher confidence level scores than overlapping PET/MRI for the novice reader (p = 0.033 and p = 0.038, respectively). The differences in bladder dimension on sequential PET/MRI were significantly larger than those on overlapping and time-synchronized PET/MRI (p <0.001).

CONCLUSION: Time-synchronized PET/MRI is superior to conventional PET/MRI for assessing the locoregional extension of endometrial cancer.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Tachibana M, Nogami M, Inoue Inukai J, et al. Time-synchronized 2-deoxy-2-[18F]fluoro-D-glucose PET/MRI with MR-active trigger and Bayesian penalized likelihood reconstruction: Diagnostic utility for locoregional extension of endometrial cancer. Eur J Radiol. 2024. PMID: 39167906. doi:10.1016/j.ejrad.2024.111678

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。