追求卓越:多中心质量改进项目优化肾绞痛患者CT KUB技术
该多中心质量改进项目在巴基斯坦8个城市12个放射科开展两轮审计,评估技术员教育前后CT KUB技术对RCR指南的依从性。第一轮依从率为0%-64%,教育后第二轮提升至35.57%-90.90%。结论认为遵循标准CT KUB扫描实践可在不牺牲诊断细节的前提下显著降低辐射剂量。
要点
- CT KUB扫描范围应上缘涵盖最高肾脏上极,避免不必要的过扫描。
- 技术员教育可显著提高CT KUB技术对RCR指南的依从性。
- 遵循标准CT KUB技术可在不牺牲诊断细节下降低辐射剂量。
核心结论
- 通过遵循CT KUB标准扫描实践,可实现显著的辐射剂量降低而不影响诊断细节。
研究设计与样本
- 多中心质量改进项目,12个放射科参与,位于巴基斯坦伊斯兰共和国8个城市;第一轮审计后经科室会议反馈并教育技术员,12周后进行第二轮审计;目标为100%符合标准;比较干预前后指南依从性;记录KUB CT轴位切片总数、最高肾脏上极以上图像(过扫描/不必要切片)及不必要图像百分比;采用Fischer精确检验和卡方检验计算差异统计学显著性。
诊断标准与关键数值
- 依据RCR指南评估CT KUB技术适当性,第一轮适当技术患者百分比为0%-64%,教育后第二轮为35.57%-90.90%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To perform audit of imaging practice in different hospitals to assess their adherence to guidelines on optimizing computerized tomography of kidneys, ureter, and bladder (CT KUB) technique in order to reduce unnecessary scan length. To assess improvement in adherence to guidelines after intervention, following education of the technologists.
MATERIAL AND METHODS: There were 12 participant radiology departments in 8 cities of Islamic Republic of Pakistan. Findings of first audit round were presented in respective departmental meetings, and technologists were educated. Second round was performed after 12 weeks. Our target was to achieve 100% compliance to standards. Comparison of adherence to guidelines before and after intervention was done. Total number of axial slices of KUB CT scan, images above upper pole of highest kidney (overscan/unnecessary slices), and percentage of unnecessary images were recorded. To calculate statistical significance of difference, Fischer exact and Chi-square tests were applied.
RESULTS: Percentage of patients with appropriate CT KUB technique according to RCR guidelines was far less in first round (0%-64%). It significantly improved after educating the technologists (35.57%-90.90%).
CONCLUSION: By following standard practice of CT KUB scan, significant radiation dose reduction is achievable without compromising diagnostic details.
ADVANCES IN KNOWLEDGE: Standardization of CT KUB examination technique can valuably contribute to reduction in unessential radiation exposure.
引用
- Zafar AN, Rehman H, Babar KS, et al. Striving for excellence: multicentre quality improvement project to optimize CT KUB technique in renal colic patients. Br J Radiol. 2024. PMID: 39185995. doi:10.1093/bjr/tqae172
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。