文献速递泌尿生殖MR

计算扩散加权成像与采集扩散加权成像在显示阴囊或睾丸病变中的对比

Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions.
PubMed 文献 · Clin Radiol · 2024-07-18

该回顾性研究纳入57例连续行阴囊MRI的男性,比较由低b值(150和600 s/mm²)生成的计算DWI(cDWI800、cDWI1000、cDWI1200、cDWI1400)与采集DWI(DWI800、DWI1000)在显示阴囊或睾丸病变中的定性和定量差异。结果显示在b值800和1000 s/mm²时两者定性和定量评估几乎等效,计算DWI易出现信号丢失伪影但可提高病变对比度。

要点

  • 在b值800和1000 s/mm²时,计算DWI与采集DWI的定性和定量评估几乎等效。
  • 计算DWI易出现信号丢失伪影,解剖清晰度和病变显示评分略低。
  • cDWI1400的中位对比度比除cDWI1200外的其他DWI序列显著更高。

核心结论

  • 在b值800和1000 s/mm²时,计算DWI与采集DWI在定性和定量评估上几乎等效;计算DWI可增强阴囊或睾丸病变的对比度。

研究设计与样本

  • 回顾性纳入57例连续行阴囊MRI的男性;由两个较低b值(150和600 s/mm²)的采集DWI生成四组计算DWI(cDWI800、cDWI1000、cDWI1200、cDWI1400),与采集DWI(DWI800、DWI1000)进行定性和定量比较。

关键影像表现/征象

  • 计算DWI易出现信号丢失伪影,解剖清晰度和病变显示评分略低于采集DWI。
  • 计算DWI和采集DWI的信噪比均随b值升高而降低。
  • 在相同b值(800和1000 s/mm²)下,计算DWI与采集DWI的中位信噪比和对比度无差异。
  • cDWI1400的中位对比度显著高于除cDWI1200外的其他DWI序列(P=1.000)。
  • 计算DWI的中位对比噪声比倾向于低于采集DWI,但无显著差异(P=0.233)。

诊断标准与关键数值

  • 定性评估包括磁化率伪影、信号丢失伪影、解剖清晰度和病变显示。
  • 定量评估包括信噪比(SNR)、对比噪声比(CNR)和病变与睾丸实质对比度(CR)。
  • 在b值800和1000 s/mm²下,计算DWI与采集DWI的中位SNR和CR无差异。
  • cDWI1400的中位CR显著高于除cDWI1200外的其他DWI序列(P=1.000)。
  • 计算DWI与采集DWI的中位CNR无显著差异(P=0.233)。

临床应用与阅片要点

  • 在b值800和1000 s/mm²时,计算DWI可作为采集DWI的等效替代用于显示阴囊或睾丸病变。
  • 计算DWI可增强阴囊或睾丸病变的对比度,但需注意其易出现信号丢失伪影且解剖清晰度和病变显示评分略低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Combining computed diffusion-weighted imaging (DWI) with readout-segmented echo-planar-imaging may shorten acquisition time and improve imaging quality. This study aimed to compare computed vs. acquired DWI qualitatively and quantitatively in visualizing scrotal or testicular lesions.

MATERIALS AND METHODS: We retrospectively enrolled 57 consecutive men who underwent scrotal MRI. Four computed DWI sets (cDWI800, cDWI1000, cDWI1200, and cDWI1400) were generated from acquired DWI with two lower b-values (150 and 600 s/mm2). Acquired DWI (DWI800 and DWI1000) and computed DWI were compared through qualitative (susceptibility artifact, signal loss artifact, anatomic clarity, and lesion conspicuity) and quantitative assessment (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion-to-testicular parenchyma contrast ratio (CR)).

RESULTS: Computed DWI was prone to signal loss artifact and slightly lower assessment scores in terms of anatomic clarity and lesion conspicuity, comparing with acquired DWI. The SNR of computed and acquired DWI decreased with increasing b value. Under the same b-values (800 and 1,000 s/mm2), there was no difference in the median SNR and CR between computed and acquired DWI. The median CR of cDWI1400 was significantly higher than that of the other DWI sets excepting cDWI1200 (P=1.000). The median CNR tended to be lower for computed vs. acquired DWI, while no significant difference (P=0.233).

CONCLUSIONS: Computed and acquired DWI were nearly equivalent in both qualitative and quantitative evaluations at the b values of 800 and 1,000 s/mm2. Computed DWI could enhance the contrast of scrotal or testicular lesions.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yao F, Li J, Huang M, et al. Comparison of computed versus acquired readout-segmented diffusion-weighted imaging in visualizing scrotal or testicular lesions. Clin Radiol. 2024. PMID: 39122632. doi:10.1016/j.crad.2024.07.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。