自适应成像接收线圈与传统线圈在肝脏多重敏感编码弥散加权成像中的比较
本研究比较自适应成像接收线圈(AIR)与传统线圈在肝脏多重敏感编码弥散加权成像(MUSE-DWI)中检测局灶性肝脏病变的图像质量与效能。结果显示AIR线圈噪声更少、轮廓更锐利、磁化率伪影更轻、病灶显示更清晰,肝脏及病灶信噪比和病灶-肝脏对比噪声比更高,病灶检出率更高(95.7% vs 85.7%)。作者认为AIR线圈是肝脏MRI可行有效的扫描方案。
要点
- AIR线圈较传统线圈显著降低图像噪声、减轻磁化率伪影并提升病灶显示清晰度。
- AIR线圈提高肝脏及局灶性肝脏病变的信噪比和病灶-肝脏对比噪声比。
- AIR线圈对局灶性肝脏病变的检出率高于传统线圈(95.7% vs 85.7%)。
核心结论
- AIR线圈在肝脏MUSE-DWI中噪声更少、失真更少、病灶检出率更高,肝脏和病灶信噪比及病灶-肝脏对比噪声比更高,是可行有效的肝脏MRI扫描方案。
研究设计与样本
- 两组MUSE-DWI图像比较研究,纳入60个肝脏共140个局灶性肝脏病变,由3名独立盲法放射科医师以5分法定性评估图像质量,并在肝脏和病灶感兴趣区测量定量参数,采用McNemar检验比较特征和检出率。
关键影像表现/征象
- 所有放射科医师均认为AIR线圈图像噪声更少、轮廓更锐利、磁化率伪影更轻、肝脏病灶显示更清晰(读者平均均分4.3-4.4 vs 3.7-4.0,P < .001)。
- AIR线圈肝脏信噪比显著高于传统线圈(右叶均值8.89 vs 7.76,P < .05;左叶均值7.14 vs 6.19,P < .001)。
- AIR线圈局灶性肝脏病变信噪比(均值24.62 vs 21.01,P < .001)和病灶-肝脏对比噪声比(均值16.61 vs 14.02,P < .001)均显著高于传统线圈。
- AIR线圈对局灶性肝脏病变的检出率高于传统线圈(95.7%[134/140] vs 85.7%[120/140],P < .001)。
诊断标准与关键数值
- 图像质量采用5分法定性评估,由3名独立盲法放射科医师评分。
- 定量参数包括肝脏左右叶信噪比、局灶性肝脏病变信噪比和病灶-肝脏对比噪声比,通过感兴趣区测量计算。
- 病变检出率以检出病变数占总病变数(140个)的百分比表示,AIR线圈95.7%(134/140)vs 传统线圈85.7%(120/140),P < .001。
临床应用与阅片要点
- 作者认为AIR线圈在肝脏MUSE-DWI中是可行有效的扫描方案,可改善图像质量和病灶检出。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the image quality and efficacy of the adaptive imaging receiver (AIR) coil (GE Healthcare) and the traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging (MUSE-DWI) in the detection of focal liver lesions (FLLs).
METHODS: Two groups of MUSE-DWI were obtained. Image quality was qualitatively evaluated by 3 independent blinded radiologists on a 5-point scale, and quantitative parameters were calculated by measurements of the region of interest in the liver and FLLs. McNemar's test were used to compare the characteristics and detectability.
RESULTS: Less image noise, sharper contours, milder susceptibility artefacts, and better liver lesion conspicuity were found by all radiologists in 60 livers with 140 FLLs with the AIR coil than with the traditional coil (reader average mean, 4.3-4.4 vs. 3.7-4.0, P < .001). The signal-to-noise ratio (SNR) of the liver was significantly higher with the AIR coil than with the traditional coil (right lobe: mean, 8.89 vs.7.76, P < .05; left lobe: mean, 7.14 vs.6.19, P < .001), and the SNR of FLLs (mean, 24.62 vs. 21.01, P < .001) and lesion-to-liver CNR (mean, 16.61 vs. 14.02, P < .001) exhibited significant differences between the AIR coil and the traditional coil. Besides, superior detection of FLLs was observed with the AIR coil compared to the traditional coil (95.7% [134/140] vs. 85.7% [120/140], P < .001).
CONCLUSIONS: The AIR coil yields less noise, fewer distortions, better lesion detectability, higher SNR of the liver and FLLs, and improved lesion-to-liver CNR during liver MUSE-DWI. Thus, it is a feasible and effective scanning scheme in liver MRI.
ADVANCES IN KNOWLEDGE: The AIR coil improves SNR and the quality of liver MR imaging compared with the traditional coil.
引用
- Peng L, Chen Q, Meng Z, et al. Comparison of adaptive imaging receiver coil and traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging of the liver. Br J Radiol. 2024. PMID: 39167448. doi:10.1093/bjr/tqae163
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。