文献速递腹部MR

评估人工智能辅助技师在肝脏分割、Couinaud分段和病灶检测中的表现:一项先导研究

Assessing the performance of AI-assisted technicians in liver segmentation, Couinaud division, and lesion detection: a pilot study.
PubMed 文献 · Abdom Radiol (NY) · 2024-08-10

本研究纳入18例结直肠癌肝转移患者的非增强T1加权MRI数据,比较3名非放射科经验操作者与3名放射科医生在AI辅助下进行全肝分割、Couinaud段分割及病灶检测与测量的准确性。非放射科组与放射科组全肝体积ICC=0.99,Couinaud段体积ICC范围0.77-0.96,两组均识别相同41个病灶,非放射科组额外识别7个结构经裁决确认为病灶,病灶直径分类一致率90%,Couinaud定位一致率91.9%。结论认为AI辅助下非放射科经验操作者与放射科医生定量肝脏体积、分段体积及检测测量病灶方面显示良好一致性。

要点

  • AI辅助下非放射科操作者与放射科医生全肝体积测量ICC=0.99,一致性高。
  • Couinaud段体积ICC范围0.77-0.96,病灶直径分类一致率90%,定位一致率91.9%。
  • 两组均识别相同41个病灶,非放射科组额外识别7个结构经裁决确认为病灶。

核心结论

  • AI辅助下非放射科经验操作者在全肝体积、Couinaud段体积定量及已知肝癌患者病灶检测和测量方面与放射科医生显示良好一致性;这种AI辅助非放射科方法有潜力在不影响准确性的情况下减轻放射科医生压力。

研究设计与样本

  • 先导研究,纳入18例结直肠癌肝转移患者的非增强T1加权MRI数据,使用AI决策支持工具,由3名非放射科经验操作者和3名放射科医生进行全肝分割、Couinaud段分割及AI生成轮廓辅助下的病灶检测和测量,另由2名放射科医生裁决病灶检测差异,采用组内相关系数(ICC)评估一致性。

诊断标准与关键数值

  • 非放射科组与放射科组全肝体积ICC=0.99。
  • Couinaud段体积ICC范围0.77-0.96。
  • 两组均识别相同41个病灶,非放射科组额外识别7个结构经裁决确认为病灶。
  • 病灶直径分类一致率90%,Couinaud定位一致率91.9%。
  • 病灶测量组内变异性两组相当。

临床应用与阅片要点

  • 在AI辅助下,非放射科经验操作者可完成全肝体积、Couinaud段体积及病灶检测测量,与放射科医生一致性良好。
  • 作者认为该AI辅助非放射科方法有潜力在不影响准确性的情况下减轻放射科医生压力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: In patients with primary and secondary liver cancer, the number and sizes of lesions, their locations within the Couinaud segments, and the volume and health status of the future liver remnant are key for informing treatment planning. Currently this is performed manually, generally by trained radiologists, who are seeing an inexorable growth in their workload. Integrating artificial intelligence (AI) and non-radiologist personnel into the workflow potentially addresses the increasing workload without sacrificing accuracy. This study evaluated the accuracy of non-radiologist technicians in liver cancer imaging compared with radiologists, both assisted by AI.

METHODS: Non-contrast T1-weighted MRI data from 18 colorectal liver metastasis patients were analyzed using an AI-enabled decision support tool that enables non-radiology trained technicians to perform key liver measurements. Three non-radiologist, experienced operators and three radiologists performed whole liver segmentation, Couinaud segment segmentation, and the detection and measurements of lesions aided by AI-generated delineations. Agreement between radiologists and non-radiologists was assessed using the intraclass correlation coefficient (ICC). Two additional radiologists adjudicated any lesion detection discrepancies.

RESULTS: Whole liver volume showed high levels of agreement between the non-radiologist and radiologist groups (ICC = 0.99). The Couinaud segment volumetry ICC range was 0.77-0.96. Both groups identified the same 41 lesions. As well, the non-radiologist group identified seven more structures which were also confirmed as lesions by the adjudicators. Lesion diameter categorization agreement was 90%, Couinaud localization 91.9%. Within-group variability was comparable for lesion measurements.

CONCLUSION: With AI assistance, non-radiologist experienced operators showed good agreement with radiologists for quantifying whole liver volume, Couinaud segment volume, and the detection and measurement of lesions in patients with known liver cancer. This AI-assisted non-radiologist approach has potential to reduce the stress on radiologists without compromising accuracy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Núñez L, Ferreira C, Mojtahed A, et al. Assessing the performance of AI-assisted technicians in liver segmentation, Couinaud division, and lesion detection: a pilot study. Abdom Radiol (NY). 2024. PMID: 39123052. doi:10.1007/s00261-024-04507-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。