文献速递腹部技术与安全CT

不同浓度碘对比剂对腹部CT检查疼痛与舒适度的影响

Impact of different concentration iodinated contrast media on pain and comfort in abdominal computed tomography.
PubMed 文献 · Eur J Radiol · 2024-08-05

前瞻性单中心研究纳入206例静脉条件为II级和III级的患者,比较高浓度碘对比剂(碘美普尔400)与低浓度碘对比剂(碘佛醇320)在相同碘流率1.12 gI/s下行腹部增强CT的疼痛与舒适度。高浓度组疼痛评分和不适评分均显著低于低浓度组,对比剂外渗发生率无显著差异,图像质量未受影响。

要点

  • 静脉条件差(II/III级)患者行腹部增强CT时,高浓度碘对比剂可降低疼痛和不适感。
  • 高浓度组与低浓度组对比剂外渗发生率无显著差异(1.0% vs 4.5%,p=0.214)。
  • 高浓度组肝内肝动脉和门静脉清晰度评分更高,定量图像评估两组相当。

核心结论

  • 高浓度碘对比剂可降低疼痛强度、提高舒适度,且不损害CT图像质量;在静脉条件差的患者中是更可取的选择。

研究设计与样本

  • 前瞻性单中心研究,2021年7月至2022年2月纳入206例静脉条件为II级和III级的患者,高浓度组99例、低浓度组107例。
  • 高浓度组使用碘美普尔400,低浓度组使用碘佛醇320,碘流率均为1.12 gI/s。
  • 静脉条件采用Intravenous Access Scoring系统分级,II级和III级表示静脉条件差、静脉穿刺困难。
  • 主要结局为疼痛和舒适度,次要结局为不良事件和图像质量。

关键影像表现/征象

  • 高浓度组肝内肝动脉和门静脉清晰度评分高于低浓度组。
  • 定量图像评估结果两组相当。

诊断标准与关键数值

  • 疼痛强度采用Numerical Rating Scale评估,评分越高疼痛越重。
  • 舒适度采用Visual Analogue Scale评估,评分越高不适感越重。
  • 高浓度组疼痛评分中位数1(IQR 0-2)vs 低浓度组2(IQR 2-4),p<0.001。
  • 高浓度组舒适度评分中位数1(IQR 0-3)vs 低浓度组3(IQR 2-5),p<0.001。
  • 对比剂外渗发生率1.0% vs 4.5%,p=0.214;未观察到过敏反应。

临床应用与阅片要点

  • 对静脉条件差(II/III级)需行腹部增强CT的患者,高浓度碘对比剂在相同碘流率下可减轻注射疼痛和不适。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate whether high concentration iodinated contrast media (CM), compared with low concentration CM, could reduce pain and discomfort levels in patients who had level II and III venous conditions.

METHODS: This prospective, single-center study enrolled patients who had level II and III venous conditions and underwent abdominal contrast-enhanced CT scan between July 2021 and February 2022. The venous condition to establish peripheral venous access for CM injection was graded using the Intravenous Access Scoring system, of which level II and III indicated poor venous condition and difficult venous access. Patients received iomeprol 400 in high concentration group and ioversol 320 in low group at an identical iodine delivery rate of 1.12 gI/s. The primary outcomes were pain and comfort levels. The secondary outcomes included adverse events and image quality. Patients rated pain intensity via Numerical Rating Scale and comfort level via Visual Analogue Scale with higher scores indicating higher levels of pain and discomfort. Quantitative and qualitative image assessment were compared between two groups. Continuous variables were compared using Student's t test or Mann-Whitney U test. Categorical variables were compared using χ2 test, χ2 test for trend or Fisher's exact test.

RESULTS: A total of 206 patients (mean age, 60.13 ± 12.14 years; 81 males) were included with 99 in the high concentration group and 107 in the low concentration group. The high group had significantly lower pain scores (median 1 [IQR: 0-2] vs 2 (IQR 2-4), p < 0.001) and comfort scores (1 [IQR: 0-3] vs 3 [IQR: 2-5], p < 0.001) than the low group. Incidence of CM extravasation did not significantly differ (1.0 % vs 4.5 %, p = 0.214). No hypersensitivity reaction was observed. Qualitative assessment showed higher clarity scores of intrahepatic hepatic artery and portal vein in the high group. Quantitative assessment results were comparable between two groups.

CONCLUSION: High concentration iodinated CM could lower pain intensity and improve comfort levels without comprising image quality of CT scan. High concentration CM is a preferable choice in patients with poor venous conditions during contrast-enhanced CT scan.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Sun YX, Shang J, Cui Y, et al. Impact of different concentration iodinated contrast media on pain and comfort in abdominal computed tomography. Eur J Radiol. 2024. PMID: 39121745. doi:10.1016/j.ejrad.2024.111664

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。