文献速递腹部CT

CT小肠造影描述纤维狭窄性克罗恩病的可靠性

Reliability of CT Enterography for Describing Fibrostenosing Crohn Disease.
PubMed 文献 · Radiology · 2024-01-01

本研究评估CT小肠造影特征描述克罗恩病狭窄的可靠性及其与狭窄严重程度的相关性,43例成人回肠末端克罗恩病狭窄患者接受标准CT小肠造影,四位腹部放射科医师盲法评估影像特征,发现5项连续测量和6项观察具有至少中等可靠性,其中狭窄长度、最大相关小肠扩张和最大狭窄壁厚度与狭窄严重程度独立相关。

要点

  • 标准化CT小肠造影测量和观察可可靠描述回肠末端克罗恩病狭窄。
  • 狭窄长度、最大相关小肠扩张和最大狭窄壁厚度与狭窄严重程度独立相关。
  • 上述三项测量可用于构建定量狭窄严重程度模型。

核心结论

  • 标准化CT小肠造影测量和观察可可靠描述回肠末端克罗恩病狭窄;狭窄长度、最大相关小肠扩张和最大狭窄壁厚度与狭窄严重程度相关。

研究设计与样本

  • 回顾性研究,纳入43例成人回肠末端克罗恩病狭窄患者,于2008年1月至2016年8月在克利夫兰诊所三级医疗中心接受标准CT小肠造影;四位腹部放射科医师在标准化定义培训后,盲法分两次独立评估影像特征。

诊断标准与关键数值

  • 评估7项连续测量和9项观察;评分者间组内相关系数(ICC)≥0.41视为可靠;5项连续测量和6项观察的评分者间ICC范围为0.42(95%CI:0.25,0.57)至0.80(95%CI:0.67,0.88)。

临床应用与阅片要点

  • 狭窄长度(评分者间ICC,0.64[95%CI:0.42,0.81])、最大相关小肠扩张(评分者间ICC,0.80[95%CI:0.67,0.88])和最大狭窄壁厚度(评分者间ICC,0.50[95%CI:0.34,0.62])在多变量模型中与狭窄严重程度独立相关(P值范围,<.001至.003)。
  • 上述三项测量用于构建定量狭窄严重程度模型,模型校准良好(乐观调整校准斜率=1.00)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Standardized methods to measure and describe Crohn disease strictures at CT enterography are needed to guide clinical decision making and for use in therapeutic studies. Purpose To assess the reliability of CT enterography features to describe Crohn disease strictures and their correlation with stricture severity. Materials and Methods A retrospective study was conducted in 43 adult patients with symptomatic terminal ileal Crohn disease strictures who underwent standard-of-care CT enterography at a tertiary care center at the Cleveland Clinic between January 2008 and August 2016. After training on standardized definitions, four abdominal radiologists blinded to all patient information assessed imaging features (seven continuous measurements and nine observations) of the most distal ileal stricture in two separate sessions (separated by ≥2 weeks) in random order. Features with an interrater intraclass correlation coefficient (ICC) of 0.41 or greater (ie, moderate reliability or better) were considered reliable. Univariable and multivariable linear regression analysis identified reliable features associated with a visual analog scale of overall stricture severity. Significant reliable features were assessed as components of a CT enterography-based model to quantitate stricture severity. Results Examinations in 43 patients (mean age, 52 years ± 16 [SD]; 23 female) were evaluated. Five continuous measurements and six observations demonstrated at least moderate interrater reliability (interrater ICC range, 0.42 [95% CI: 0.25, 0.57] to 0.80 [95% CI: 0.67, 0.88]). Of these, 10 were univariably associated with stricture severity, and three continuous measurements-stricture length (interrater ICC, 0.64 [95% CI: 0.42, 0.81]), maximal associated small bowel dilation (interrater ICC, 0.80 [95% CI: 0.67, 0.88]), and maximal stricture wall thickness (interrater ICC, 0.50 [95% CI: 0.34, 0.62])-were independently associated (P value range, <.001 to .003) with stricture severity in a multivariable model. These three measurements were used to derive a well-calibrated (optimism-adjusted calibration slope = 1.00) quantitative model of stricture severity. Conclusion Standardized CT enterography measurements and observations can reliably describe terminal ileal Crohn disease strictures. Stricture length, maximal associated small bowel dilation, and maximal stricture wall thickness are correlated with stricture severity. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder et al in this issue. See also the editorial by Galgano and Summerlin in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Rieder F, Ma C, Hanzel J, et al. Reliability of CT Enterography for Describing Fibrostenosing Crohn Disease. Radiology. 2024. PMID: 39105638. doi:10.1148/radiol.233038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。