文献速递心血管MR

基于3T心脏磁共振原生血池T1时间估算合成红细胞压积与细胞外容积:转换公式推导、准确性及与已发表公式的比较

Estimating synthetic hematocrit and extracellular volume from native blood pool T1 times at 3 Tesla CMR: Derivation of a conversion equation, accuracy and comparison with published formulas.
PubMed 文献 · Eur J Radiol · 2024-07-31

本研究为回顾性研究,纳入250例3T心脏磁共振T1 mapping扫描,推导出由左心室血池原生T1估算合成红细胞压积的线性回归公式(Hctsyn = 1/T1native,midLV * 1355.52 - 0.310),并在验证队列中显示合成ECV与真实ECV高度相关(r=0.940),误分类率8.8%与重复测量红细胞压积的变异性(7.5%)相当,而已发表公式误分类率高达60%。

要点

  • 3T下左心室血池原生T1与24小时内红细胞压积呈负相关(r=-0.711)。
  • 推导公式Hctsyn = 1/T1native,midLV * 1355.52 - 0.310用于估算合成红细胞压积。
  • 合成ECV误分类率8.8%与重复测量红细胞压积的7.5%相当,但已发表公式误分类率高达60%。

核心结论

  • 本研究提供了在3T扫描仪上由原生血池T1估算合成红细胞压积的公式,合成ECV的测量误差低,与常规红细胞压积重复测量变异性相当,应使用针对扫描仪和序列特异的公式。

研究设计与样本

  • 回顾性研究,共250例心脏磁共振T1 mapping扫描(3T,MOLLI 5(3)3,收缩末期采集),分为推导队列(n=167)和验证队列(n=83);以24小时内血样红细胞压积(Hct24h)为参考标准。

诊断标准与关键数值

  • 推导队列中Hct24h与T1native,midLV相关(r=-0.711,p<0.001)。
  • 回归公式:Hctsyn = 1/T1native,midLV * 1355.52 - 0.310。
  • 验证队列中Hctsyn与Hct24h相关(r=0.726,p<0.001),ECVsyn与ECV24h相关(r=0.940,p<0.001)。
  • ECVsyn偏差为0.28%,误分类率8.8%,重复红细胞压积测量误分类率7.5%。
  • 应用已发表公式在本队列中误分类率高达60%。

临床应用与阅片要点

  • 在3T心脏磁共振T1 mapping中,可由左心室血池原生T1按公式Hctsyn = 1/T1native,midLV * 1355.52 - 0.310估算合成红细胞压积用于ECV计算。
  • 应使用针对扫描仪和序列特异的公式,已发表公式在本队列中误分类率高达60%。

局限性

  • 本研究的公式针对3T扫描仪和MOLLI 5(3)3序列,应使用扫描仪和序列特异的公式。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Calculation of extracellular volume fraction (ECV), a marker of myocardial fibrosis in cardiac magnetic resonance imaging (CMR), requires hematocrit (Hct). We aimed to correlate Hct levels with native blood T1 times, to derive a formula for estimating synthetic Hct (Hctsyn) and synthetic ECV (ECVsyn), to assess accuracy of ECVsyn and to compare our model with published formulas.

METHOD: In this retrospective study, a cohort of 250 CMR scans with T1 mapping (3T, MOLLI 5(3)3, endsystolic aquisition), was divided into a derivation and validation cohort. Native T1 times of the left ventricular blood pool (T1native,midLV) were correlated with Hct levels from blood sampling within 24 h (Hct24h) and a formula for calculation of Hctsyn was derived by linear regression.

RESULTS: In the derivation cohort (n = 167), Hct24h showed a good association with T1native,midLV (r = -0.711, p < 0.001). The resulting regression equation was Hctsyn = 1/T1native,midLV * 1355.52-0.310. In the validation cohort (n = 83), Hctsyn and Hct24h showed good correlation (r = 0.726, p < 0.001), while ECVsyn, and ECV24h demonstrated excellent correlation (r = 0.940, p < 0.001). ECVsyn had a minimal bias of 0.28 % and the misclassification rate (8.8 %) was comparable to the variability introduced by repeated Hct measurements (misclassification in 7.5 %). Applying published formulas in our cohort resulted in incorrect classification in up to 60 %.

CONCLUSION: We provide a formula for estimating Hctsyn from native blood T1 on a 3T scanner. The measurement error of ECVsyn is low and comparable to the error due to retest variability of conventional Hct. Scanner- and sequence-specific formulas should be used.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Reiter C, Puseljic M, Fuchsjäger M, et al. Estimating synthetic hematocrit and extracellular volume from native blood pool T1 times at 3 Tesla CMR: Derivation of a conversion equation, accuracy and comparison with published formulas. Eur J Radiol. 2024. PMID: 39096824. doi:10.1016/j.ejrad.2024.111659

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。