原生T1 mapping放射组学对轻链型心脏淀粉样变性诊断的增量价值
该回顾性研究纳入86例疑似AL-CA患者和28例对照,基于3.0T心脏MRI原生T1 mapping提取放射组学特征,用LASSO构建模型。放射组学评分在训练集和测试集检测心肌受累的敏感度均显著高于T1值,联合模型AUC分别为0.929和0.909,提示原生T1 mapping放射组学对AL-CA诊断有增量价值。
要点
- 放射组学评分检测心肌受累的敏感度显著高于T1值,训练集AUC 0.886 vs 0.924(P=0.025)。
- 测试集放射组学评分AUC 0.862 vs T1值0.915(P=0.026),放射组学评分更高。
- T1值与放射组学特征S(4,-4) Correlat联合模型训练集AUC 0.929、测试集0.909。
核心结论
- 原生T1 mapping衍生的放射组学特征对AL-CA诊断具有增量价值,可能替代T1衍生的ECV以避免对疑似系统性淀粉样变性心肌受累患者使用对比剂。
研究设计与样本
- 回顾性收集本院86例疑似AL-CA患者和28例对照的3.0T心脏MRI数据,分为训练集和测试集。
诊断标准与关键数值
- T1值诊断心肌受累的准确度为0.886,阈值为1375 ms;放射组学评分由3个特征组成。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to assess the incremental diagnostic value of non-contrast T1 mapping-derived radiomics in patients with amyloid light-chain cardiac amyloidosis (AL-CA).
METHODS: We retrospectively collected 86 patients with suspected AL-CA and 28 control patients who underwent cardiac MRI at 3.0 T in our institution, and the MRI data were divided into a training set and a test set. Radiomic features were extracted based on native T1 maps using a freely available software package. We applied LASSO logistic regression method to select radiomic features with high diagnostic value of AL-CA and develop a predictive model. The diagnostic performance of the radiomics model was evaluated using receiver operating characteristic curve analysis and compared to T1 values.
RESULTS: A total of 70 people were diagnosed with AL-CA, and cardiac involvement was observed in 202 myocardial slicers. The accuracy of T1 values for the diagnosis of myocardial involvement was 0.886, with a threshold value of 1375 ms. The radiomics score comprised a total of three features. The radiomics score demonstrated significantly higher sensitivity in detecting myocardial involvement compared to T1 values in both the training set (AUC 0.886 vs. 0.924, P = 0.025) and the test set (0.862 vs 0.915, P = 0.026). The combined model comprising T1 values and a radiomic feature named S(4,-4) Correlat showed higher diagnostic performance in comparison to T1 values alone both in the training and test sets, with AUC values of 0.929 and 0.909, respectively.
CONCLUSION: The radiomic features derived from native T1 mapping demonstrated incremental value for the diagnosis of AL-CA, which may be an alternative to T1-derived ECV to avoid the use of contrast in patients with suspected myocardial involvement in systemic amyloidosis.
引用
- Ma Q, Chen J, Cao L, et al. The Incremental Value of Native T1 Mapping-Derived Radiomics for The Diagnosis of Amyloid Light-Chain Cardiac Amyloidosis. Acad Radiol. 2024. PMID: 39107187. doi:10.1016/j.acra.2024.07.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。