基于深度学习图像转换的门控SPECT衍生心肌应变经N-13氨PET验证
本研究利用同一患者配对图像训练SPECT到PET的深度学习转换模型,在负荷态(18例720对)和静息态(23例920对)生成虚拟PET样门控SPECT图像(SPECTVP),并用特征追踪算法测量周向和纵向应变。SPECTVP负荷态周向应变的ICC达0.78,优于常规SPECT的0.56,纵向应变ICC亦达0.83和0.91。
要点
- SPECTVP负荷态周向应变ICC为0.78,优于SPECT的0.56。
- SPECT和SPECTVP的负荷态纵向应变ICC分别为0.83和0.91。
- 深度学习SPECT到PET转换可提升常规门控SPECT的周向应变测量精度。
核心结论
- 深度学习SPECT到PET转换利用标准门控SPECT提高了周向应变测量精度,并展示了通过PET和SPECTVP进行纵向应变测量的可能性;标准门控SPECT经后处理获得的SPECTVP可能通过PET等效心肌应变分析增加临床价值而不增加患者负担。
研究设计与样本
- 研究使用同一患者配对图像训练短轴、水平长轴和垂直长轴平面的SPECT到PET转换模型,负荷态720对图像来自18例患者,静息态920对图像来自23例患者,训练纳入SPECT与PET期间射血分数无变化的患者;采用特征追踪算法独立分析短轴门控SPECT、PET和模型生成的SPECTVP图像的周向应变,并从水平长轴和垂直长轴图像测量纵向应变。
诊断标准与关键数值
- 采用双向随机单次测量计算SPECT与SPECTVP(PET)的组内相关系数(ICC)及95%置信区间,ICC≥0.75为优秀、0.60-0.74为良好、0.40-0.59为中等、≤0.39为差;SPECT负荷态周向应变ICC为0.56(0.41-0.69),SPECTVP负荷态周向应变ICC为0.78(0.68-0.85),SPECT和SPECTVP负荷态水平长轴纵向应变ICC为0.83(0.73-0.90),垂直长轴纵向应变ICC为0.91(0.85-0.94)。
局限性
- 本研究提供的是初步证据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study investigated the use of deep learning-generated virtual positron emission tomography (PET)-like gated single-photon emission tomography (SPECTVP) for assessing myocardial strain, overcoming limitations of conventional SPECT.
MATERIALS AND METHODS: SPECT-to-PET translation models for short-axis, horizontal, and vertical long-axis planes were trained using image pairs from the same patients in stress (720 image pairs from 18 patients) and resting states (920 image pairs from 23 patients). Patients without ejection-fraction changes during SPECT and PET were selected for training. We independently analyzed circumferential strains from short-axis-gated SPECT, PET, and model-generated SPECTVP images using a feature-tracking algorithm. Longitudinal strains were similarly measured from horizontal and vertical long-axis images. Intraclass correlation coefficients (ICCs) were calculated with two-way random single-measure SPECT and SPECTVP (PET). ICCs (95% confidence intervals) were defined as excellent (≥0.75), good (0.60-0.74), moderate (0.40-0.59), or poor (≤0.39).
RESULTS: Moderate ICCs were observed for SPECT-derived stressed circumferential strains (0.56 [0.41-0.69]). Excellent ICCs were observed for SPECTVP-derived stressed circumferential strains (0.78 [0.68-0.85]). Excellent ICCs of stressed longitudinal strains from horizontal and vertical long axes, derived from SPECT and SPECTVP, were observed (0.83 [0.73-0.90], 0.91 [0.85-0.94]).
CONCLUSION: Deep-learning SPECT-to-PET transformation improves circumferential strain measurement accuracy using standard-gated SPECT. Furthermore, the possibility of applying longitudinal strain measurements via both PET and SPECTVP was demonstrated. This study provides preliminary evidence that SPECTVP obtained from standard-gated SPECT with postprocessing potentially adds clinical value through PET-equivalent myocardial strain analysis without increasing the patient burden.