深度学习重建用于零回波时间肺磁共振成像:对图像质量和病灶检出的影响
本研究纳入59例同时接受胸部CT和零回波时间(ZTE)肺MRI的患者,比较不同强度深度学习重建(DLR-M、DLR-H)与常规滤波(NF1~NF4)对ZTE肺MRI噪声、锐利度及病灶检出的影响。结果显示DLR在降低噪声的同时保持图像纹理和锐利度,DLR-H的主观图像质量最高,对亚厘米结节和肺气肿的检出优于原图。
要点
- DLR降低ZTE肺MRI噪声且不改变空间频率,常规滤波则使空间频率向低频偏移。
- DLR-M、DLR-H的模糊度指标与原图无显著差异,NF1~NF4则显著高于原图。
- DLR-H主观图像质量最高,对亚厘米结节和肺气肿的检出优于原图。
核心结论
- DLR可在保持图像纹理和锐利度的同时改善ZTE肺MRI质量,从而提升ZTE评估肺实质疾病的潜力。
研究设计与样本
- 研究纳入59例同时接受胸部CT和ZTE肺MRI的患者,比较不同强度DLR(DLR-M、DLR-H)与常规图像滤波技术(NF1~NF4)的降噪效果,并通过体模实验分析归一化噪声功率谱(NPS),以模糊度指标评价图像锐利度。
关键影像表现/征象
- NF1~NF4、DLR-M和DLR-H的NPS峰值均低于原图。
- 随着NF等级增加,NPS平均空间频率向低频偏移,而DLR不改变平均空间频率。
- NF1~NF4的模糊度指标显著高于原图(p<0.008),DLR-M、DLR-H与原图无显著差异。
诊断标准与关键数值
- DLR-H的主观图像质量评分最高,较原图有统计学显著改善(p<0.05)。
- DLR-H对亚厘米结节的诊断信心高于原图。
- DLR-H对肺气肿的检出诊断性能高于原图。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: This study aimed to examine the impact of deep-learning reconstruction (DLR) on zero echo time (ZTE) lung MRI.
MATERIALS AND METHODS: Fifty-nine patients who underwent both chest CT and ZTE lung magnetic resonance imaging (MRI) were enrolled. Noise reduction in ZTE lung MRI was compared using various DLR intensities (DLR-M, DLR-H) and conventional image filtering techniques (NF1 ∼ NF4). The normalized noise power spectrum (NPS) was analysed through phantom experiments. Image sharpness was evaluated using a blur metric. We compared subjective image quality and the detection of sub-centimetre nodules and emphysema between the original and noise-reduced images. Statistical analyses included the Wilcoxon signed-rank and McNemar's tests, with inter-reader agreement assessed via Kappa coefficients.
RESULTS: NPS peaks were lower in NF1 through NF4, DLR-M, and DLR-H compared to the original images. While the average spatial frequency of the NPS shifted towards lower frequencies with increasing NF levels, it remained unchanged with DLR. Blur metric values of NF1∼NF4 were significantly higher than those of the original images (p<0.008). However, there were no significant differences in blur metric values between DLR-M, DLR-H, and the original images. Image quality was rated highest for DLR-H, with a statistically significant improvement over the original (p<0.05). DLR-H showed higher diagnostic confidence for detecting sub-centimetre nodules than the original images. DLR-H showed higher diagnostic performance than the original for detecting emphysema.
CONCLUSIONS: DLR can improve ZTE lung MRI quality while preserving image texture and sharpness, thereby enhancing the potential of ZTE for evaluating pulmonary parenchymal disease.
引用
- Bae K, Lee J, Jung Y, et al. Deep learning reconstruction for zero echo time lung magnetic resonance imaging: impact on image quality and lesion detection. Clin Radiol. 2024. PMID: 39112100. doi:10.1016/j.crad.2024.07.011