文献速递胸部腹部技术与安全CT

基于机器学习的CT多器官/组织患者特异性辐射剂量测定流程

A machine learning-based pipeline for multi-organ/tissue patient-specific radiation dosimetry in CT.
PubMed 文献 · Eur Radiol · 2024-08-13

本研究回顾性收集95例胸部CT和85例腹部CT,为每例进行个性化蒙特卡罗模拟,并开发器官/组织特异性剂量预测深度神经网络,与开源器官分割工具整合成流程,可自动估算30个器官/组织(包括心脏和肺亚体积)的辐射剂量;结果显示预测与模拟剂量差异无统计学意义(p值>0.18),平均推理时间77.0±11.0秒。

要点

  • 该流程可自动估算30个器官/组织(含心脏和肺亚体积)的CT辐射剂量。
  • 预测剂量与蒙特卡罗模拟剂量差异无统计学意义(p值>0.18)。
  • 验证队列平均推理时间为77.0±11.0秒,算法与模型已公开。

核心结论

  • 所提出的工作流程能够快速、准确地估算器官/组织辐射剂量,算法和剂量预测深度神经网络已公开。

研究设计与样本

  • 回顾性研究,收集95例胸部CT和85例腹部CT,每例进行个性化蒙特卡罗模拟,开发器官/组织特异性剂量预测深度神经网络,并与开源器官分割工具整合成流程,评估准确性和时间效率。

诊断标准与关键数值

  • 蒙特卡罗模拟剂量与深度神经网络预测剂量之间的中位百分比差异最低见于肺血管(4.3%)、小肠(4.7%)、肺动脉(4.7%)和结肠(5.2%),最高见于右肺上叶(13.3%)、脾(13.1%)、胰腺(12.1%)和胃(11.6%);统计检验显示差异无统计学意义(p值>0.18)。

临床应用与阅片要点

  • 该流程可用于CT患者特异性剂量估算,作者指出通过采用该工作流程,机构可利用自动化流程进行CT患者特异性剂量测定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a machine learning-based pipeline for multi-organ/tissue personalized radiation dosimetry in CT.

MATERIALS AND METHODS: For the study, 95 chest CT scans and 85 abdominal CT scans were collected retrospectively. For each CT scan, a personalized Monte Carlo (MC) simulation was carried out. The produced 3D dose distributions and the respective CT examinations were utilized for the development of organ/tissue-specific dose prediction deep neural networks (DNNs). A pipeline that integrates a robust open-source organ segmentation tool with the dose prediction DNNs was developed for the automatic estimation of radiation doses for 30 organs/tissues including sub-volumes of the heart and lungs. The accuracy and time efficiency of the presented methodology was assessed. Statistical analysis (t-tests) was conducted to determine if the differences between the ground truth organ/tissue radiation dose estimates and the respective dose predictions were significant.

RESULTS: The lowest median percentage differences between MC-derived organ/tissue doses and DNN dose predictions were observed for the lung vessels (4.3%), small bowel (4.7%), pulmonary artery (4.7%), and colon (5.2%), while the highest differences were observed for the right lung's upper lobe (13.3%), spleen (13.1%), pancreas (12.1%), and stomach (11.6%). Statistical analysis showed that the differences were not significant (p-value > 0.18). Furthermore, the mean inference time, regarding the validation cohort, of the developed methodology was 77.0 ± 11.0 s.

CONCLUSION: The proposed workflow enables fast and accurate organ/tissue radiation dose estimations. The developed algorithms and dose prediction DNNs are publicly available ( https://github.com/eltzanis/multi-structure-CT-dosimetry ).

CLINICAL RELEVANCE STATEMENT: The accuracy and time efficiency of the developed pipeline compose a useful tool for personalized dosimetry in CT. By adopting the proposed workflow, institutions can utilize an automated pipeline for patient-specific dosimetry in CT.

KEY POINTS: Personalized dosimetry is ideal, but is time-consuming. The proposed pipeline composes a tool for facilitating patient-specific CT dosimetry in routine clinical practice. The developed workflow integrates a robust open-source segmentation tool with organ/tissue-specific dose prediction neural networks.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tzanis E, Damilakis J. A machine learning-based pipeline for multi-organ/tissue patient-specific radiation dosimetry in CT. Eur Radiol. 2024. PMID: 39136706. doi:10.1007/s00330-024-11002-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。