文献速递胸部CT

使用光子计数探测器CT超高分辨率与1024像素矩阵评估系统性硬化症患者队列中的间质性肺病

Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix.
PubMed 文献 · Br J Radiol · 2024-01-01

回顾性纳入66例接受间质性肺病CT筛查的系统性硬化症患者,在第一代光子计数探测器CT上以超高分辨率模式100 kVp扫描,比较512×512与1024×1024两种矩阵及1.5 mm与0.2 mm层厚重建的图像质量与间质性肺病改变。0.2 mm层厚图像锐度及间质性肺病改变可见性显著优于1.5 mm,1024矩阵在评估粗网状影方面优于512矩阵,图像质量以1.5 mm/1024矩阵最高。

要点

  • 0.2 mm层厚重建的图像锐度和间质性肺病改变可见性显著优于1.5 mm层厚。
  • 1024矩阵在评估粗网状影方面优于512矩阵,但两种矩阵间间质性肺病改变无显著差异。
  • 图像质量以1.5 mm/1024矩阵最高,读者1评4分(4.4),读者2评5分(4.5)。

核心结论

  • 超高分辨率模式联合0.2 mm层厚较标准重建可提升图像锐度和间质性肺病改变可见性,可能有助于早期检出细微病变。

研究设计与样本

  • 回顾性纳入66例接受间质性肺病CT筛查的系统性硬化症患者,在第一代光子计数探测器CT上以超高分辨率模式100 kVp扫描,比较512×512与1024×1024两种矩阵及1.5 mm与0.2 mm层厚重建。

关键影像表现/征象

  • 图像锐度在0.2 mm层厚图像中评分显著更优(P < .001)。
  • 间质性肺病改变(磨玻璃影和网状影)在0.2 mm层厚显著优于1.5 mm层厚(P < .001)。
  • 评估粗网状影时1024矩阵优于512矩阵。

诊断标准与关键数值

  • 图像噪声、主观图像质量和间质性肺病改变(磨玻璃影和网状影)由两名独立读者采用5点Likert量表评估。
  • 读者间一致性Krippendorff-Alpha为0.258–0.862,范围从一般到几乎完全一致。
  • 总体图像质量以1.5 mm/1024矩阵最高,读者1评4分(4.4),读者2评5分(4.5)。

临床应用与阅片要点

  • 原文结论认为超高分辨率模式联合0.2 mm层厚在检出硬皮病患者肺实质改变方面有益。
  • 原文指出超高分辨率模式联合0.2 mm层厚有潜力实现细微疾病表现的早期检测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study assessed the potential of ultra-high resolution (UHR) and a 1024-matrix in photon-counting-detector CT (PCD-CT) for evaluating interstitial lung disease (ILD) in systemic sclerosis (SSc) patients.

METHODS: Sixty-six SSc patients who underwent ILD-CT screening on a first-generation PCD-CT were retrospectively included. Scans were performed in UHR mode at 100 kVp with two different matrix sizes (512×512 and 1024x1024) and reconstructed at slice thicknesses of 1.5 and 0.2 mm. Image noise, subjective image quality, and ILD changes (ground glass opacities and reticulations) were evaluated on a 5-point Likert-scale by two independent readers.

RESULTS: Interreader agreement for subjective image quality ranged from fair to almost perfect (Krippendorff-Alpha: 0.258-0.862). Overall image quality was highest for 1.5 mm/1024 matrix images [(reader 1: 4(4.4), reader 2: 5(4.5)]. Image sharpness was rated significantly better in 0.2 mm images (P < .001). Regarding ILD changes, 0.2 mm slice thickness outperformed 1.5 mm slice thickness significantly (P < .001), while there was no significant difference between the two matrix sizes. A 1024-matrix size demonstrated superiority in evaluating coarse reticulations compared to 512-matrix size.

CONCLUSION: UHR mode with a 0.2 mm slice thickness showed enhanced image sharpness and improved visibility of ILD changes compared to standard reconstructions. This has the potential to enable the early detection of subtle disease manifestations.

ADVANCES IN KNOWLEDGE: With the invention of PCD-CT different reconstruction algorithms need to be evaluated for specific pathologies. In our study ILD UHR mode with 0.2 mm slice thickness showed to be beneficial in the detection of parenchymal changes in patients with scleroderma.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Jungblut L, Sartoretti T, Landsmann A, et al. Assessment of interstitial lung disease in a systemic sclerosis patient cohort using photon-counting detector CT with ultra-high resolution and a 1024-pixel image matrix. Br J Radiol. 2024. PMID: 39189964. doi:10.1093/bjr/tqae170

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。