文献速递胸部CT

光子计数探测器CT在尸体人肺结节与气道中的放射-组织学对照研究

Photon-Counting Detector CT Radiological-Histological Correlation in Cadaveric Human Lung Nodules and Airways.
PubMed 文献 · Invest Radiol · 2024-08-20

本研究对20例尸体肺行EID-CT与PCD-CT扫描,并以组织学为参考比较两者显示结节和气道的性能。PCD-CT对小结节和气道的显示优于EID-CT,且随空间分辨率提高而改善,PCD-1024-FOV50可检出亚毫米结节和气道。

要点

  • PCD-CT对肺结节和气道的显示评分均优于EID-CT,且随重建矩阵和FOV缩小而提高。
  • PCD-1024-FOV50上勉强可检出结节中位大小604 μm,气道601 μm。
  • EID-CT上勉强可检出结节中位大小837 μm,气道1210 μm。

核心结论

  • PCD-CT显示小结节和气道优于EID-CT,并随高空间分辨率改善,可能检出亚毫米结节和气道。

研究设计与样本

  • 对既往获得的20例尸体肺行EID-CT和PCD-CT扫描,辐射剂量与噪声水平等效于诊断参考水平,PCD-CT采用超高分辨率模式。

关键影像表现/征象

  • 结节和气道的评分按PCD-1024-FOV50、PCD-1024-FOV350、PCD-512、EID-CT顺序降低。
  • PCD-1024-FOV50上勉强可检出结节中位大小604 μm(IQR 469-756 μm),气道601 μm(IQR 489-929 μm)。
  • EID-CT上勉强可检出结节中位大小837 μm(IQR 678-914 μm),气道1210 μm(IQR 674-1435 μm)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare the performances of photon-counting detector computed tomography (PCD-CT) and energy-integrating detector computed tomography (EID-CT) for visualizing nodules and airways in human cadaveric lungs.

MATERIALS AND METHODS: Previously obtained 20 cadaveric lungs were scanned, and images were prospectively acquired by EID-CT and PCD-CT at a radiation dose with a noise level equivalent to the diagnostic reference level. PCD-CT was scanned with ultra-high-resolution mode. The EID-CT images were reconstructed with a 512 matrix, 0.6-mm thickness, and a 350-mm field of view (FOV). The PCD-CT images were reconstructed at 3 settings: PCD-512: same as EID-CT; PCD-1024-FOV350: 1024 matrix, 0.2-mm thickness, 350-mm FOV; and PCD-1024-FOV50: 1024 matrix, 0.2-mm thickness, 50-mm FOV. Two specimens per lung were examined after hematoxylin and eosin staining. The CT images were evaluated for nodules on a 5-point scale and for airways on a 4-point scale to compare the histology. The Wilcoxon signed rank test with Bonferroni correction was performed for statistical analyses.

RESULTS: Sixty-seven nodules (1321 μm; interquartile range [IQR], 758-3105 μm) and 92 airways (851 μm; IQR, 514-1337 μm) were evaluated. For nodules and airways, scores decreased in order of PCD-1024-FOV50, PCD-1024-FOV350, PCD-512, and EID-CT. Significant differences were observed between series other than PCD-1024-FOV350 versus PCD-1024-FOV50 for nodules (PCD-1024-FOV350 vs PCD-1024-FOV50, P = 0.063; others P < 0.001) and between series other than EID-CT versus PCD-512 for airways (EID-CT vs PCD-512, P = 0.549; others P < 0.005). On PCD-1024-FOV50, the median size of barely detectable nodules was 604 μm (IQR, 469-756 μm) and that of barely detectable airways was 601 μm (IQR, 489-929 μm). On EID-CT, that of barely detectable nodules was 837 μm (IQR, 678-914 μm) and that of barely detectable airways was 1210 μm (IQR, 674-1435 μm).

CONCLUSIONS: PCD-CT visualized small nodules and airways better than EID-CT and improved with high spatial resolution and potentially can detect submillimeter nodules and airways.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Hata A, Yanagawa M, Ninomiya K, et al. Photon-Counting Detector CT Radiological-Histological Correlation in Cadaveric Human Lung Nodules and Airways. Invest Radiol. 2024. PMID: 39159364. doi:10.1097/RLI.0000000000001117

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。