基于双能CT的影像组学预测浸润性肺腺癌病理分级
回顾性纳入107例术前浸润性肺腺癌患者(低级别80例、高级别27例),基于50keV和150keV虚拟单能图像提取双能CT影像组学特征并构建四种模型。双能CT影像组学模型在训练集和测试集AUC分别为0.997和0.743,测试集表现优于常规CT影像组学模型(AUC 0.529)和混合模型(AUC 0.707),并提供更大净获益。
要点
- 双能CT影像组学模型测试集AUC为0.743,优于常规CT影像组学模型的0.529。
- 临床-双能CT模型纳入肿瘤密度、分叶及AP有效原子序数,训练集和测试集AUC均为0.836。
- 常规CT影像组学模型训练集AUC 0.998但测试集仅0.529,提示过拟合可能。
核心结论
- 与常规CT影像组学模型相比,双能CT影像组学模型对浸润性肺腺癌病理分级具有更好的预测性能,测试集AUC为0.743,并提供更大净获益。
研究设计与样本
- 回顾性研究纳入107例术前浸润性肺腺癌患者(低级别80例、高级别27例),测量临床特征、影像学特征及定量参数,重建50keV和150keV虚拟单能图像提取双能CT影像组学特征,采用Pearson相关分析、组内相关系数及LASSO惩罚逻辑回归筛选特征,构建双能CT影像组学模型、临床-双能CT模型、常规CT影像组学模型及混合模型四种模型,以AUC和决策曲线分析评价性能与临床价值。
诊断标准与关键数值
- 双能CT影像组学模型训练集AUC 0.997、测试集AUC 0.743;临床-双能CT模型(纳入肿瘤密度、分叶及AP有效原子序数)训练集和测试集AUC均为0.836;常规CT影像组学模型训练集AUC 0.998、测试集AUC 0.529;混合模型训练集AUC 0.988、测试集AUC 0.707。
临床应用与阅片要点
- 双能CT影像组学模型在测试集AUC为0.743,优于常规CT影像组学模型的0.529,作者结论认为双能CT影像组学模型预测性能更佳。
- 临床-双能CT模型纳入肿瘤密度、分叶及AP有效原子序数,训练集和测试集AUC均为0.836,与双能CT影像组学模型表现相当。
- 常规CT影像组学模型训练集AUC 0.998、测试集AUC 0.529,原文未就此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: The purpose of the study was to build a radiomics model using Dual-energy CT (DECT) to predict pathological grading of invasive lung adenocarcinoma.
MATERIALS AND METHODS: The retrospective study enrolled 107 patients (80 low-grade and 27 high-grade) with invasive lung adenocarcinoma before surgery. Clinical features, radiographic characteristics, and quantitative parameters were measured. Virtual monoenergetic images at 50kev and 150kev were reconstructed for extracting DECT radiomics features. To select features for constructing models, Pearson's correlation analysis, intraclass correlation coefficients, and least absolute shrinkage and selection operator penalized logistic regression were performed. Four models, including the DECT radiomics model, the clinical-DECT model, the conventional CT radiomics model, and the mixed model, were established. Area under the curve (AUC) and decision curve analysis were used to measure the performance and the clinical value of the models.
RESULTS: The radiomics model based on DECT exhibited outstanding performance in predicting tumor differentiation, with an AUC of 0.997 and 0.743 in the training and testing sets, respectively. Incorporating tumor density, lobulation, and effective atomic number at AP, the clinical-DECT model showed a comparable performance with an AUC of 0.836 in both the training and testing sets. In comparison to the conventional CT radiomics model (AUC of 0.998 in the training and 0.529 in the testing set) and the mixed model (AUC of 0.988 in the training and 0.707 in the testing set), the DECT radiomics model demonstrated a greater AUC value and provided patients with a more significant net benefit in the testing set.
CONCLUSIONS: In contrast to the conventional CT radiomics model, the DECT radiomics model produced greater predictive performance in pathological grading of invasive lung adenocarcinoma.
引用
- Zheng Y, Li H, Zhang K, et al. Dual-energy CT-based radiomics for predicting pathological grading of invasive lung adenocarcinoma. Clin Radiol. 2024. PMID: 39098469. doi:10.1016/j.crad.2024.07.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。